WAGO 2110-5201 Terminal Block, 2 Positions, 20 AWG, 57A, 800V, Push-In CAGE CLAMP, DIN Rail Mount
Wago
$7.38
TOPJOBS feedthrough terminal block with Lever and Push-button; rail mount; 2-conductor; 10 mm wide; gray.
The WAGO 2110 TOPJOB S series feed-through terminal block is a gray, single-deck unit with a lever, button, and side/center marking slots, featuring a test port. It supports one feed-through pole for two wires using push-in connections, with a nominal cross-section of 10mm², suitable for wire sizes ranging from 0.5mm² to 16mm² or #20AWG to #6AWG. It has a rated current of 57A or 74A and utilizes Push-in CAGE CLAMP spring connections. The terminal block is designed for mounting on a DIN-35 rail (35 x 15 / 35 x 7.5) and has a width of 10mm, equivalent to model 21105201.
- actuation type:
- Push-in || Operating tool
- approvals per:
- C22.2 No 158
- Color:
- Gray
- connectable conductor materials:
- Copper
- connection technology:
- Push-in CAGE CLAMP
- country of origin sales organisation germany:
- PL
- depth from upper edge of din rail:
- 36.9 mm / 1.453 inch
- design:
- Horizontal type
- fine stranded conductor:
- 0.5 16 mm / 20 6 AWG
- fine stranded conductor with ferrule push in termination:
- 4 10 mm / 12 8 AWG
- fine stranded conductor with insulated ferrule:
- 0.5 10 mm / 20 8 AWG
- fire load:
- 0.029 MJ
- flammability class per ul94:
- V0
- height:
- 89 mm / 3.504 inch
- insulation material:
- Polyamide (PA66)
- legend ratings:
- (III / 3) Overvoltage category III / Pollution degree 3
- marking level:
- Center/side marking
- mounting type:
- DIN-35 rail
- nominal cross section:
- 10 mm
- nominal voltage iii 3:
- 800 V
- note conductor cross section:
- Depending on the conductor characteristic, a conductor with a smaller cross-section can also be inserted via push-in termination.
- packaging type:
- Box
- rated current:
- 57 A
- rated current 2:
- 74 A
- rated current csa use group b:
- 65 A
- rated current csa use group c:
- 65 A
- rated current ex e ii:
- 57 A
- rated current ex e ii with jumper:
- 50 A
- rated current ul use group b:
- 65 A
- rated current ul use group c:
- 65 A
- rated surge voltage iii 3:
- 8 kV
- rated voltage csa use group b:
- 600 V
- rated voltage csa use group c:
- 600 V
- rated voltage en ex e ii:
- 550 V
- rated voltage ul use group b:
- 600 V
- rated voltage ul use group c:
- 600 V
- ratings per:
- ATEX: PTB 19 ATEX 1017 U / IECEx: PTB 19.0047U (Ex eb IIC Gb)
- solid conductor:
- 0.5 16 mm / 20 6 AWG
- solid conductor push in termination:
- 4 16 mm / 14 6 AWG
- strip length:
- 17 19 mm / 0.67 0.75 inch
- weight:
- 25.712 g
- width:
- 10 mm / 0.394 inch
- wiring direction:
- Front-entry wiring