WAGO 2857-550

(No reviews yet) Write a Review
SKU:
2857-550
Condition:
New
bounce time typ:
8 ms
configurable rise fall delay time do:
0 60 s (via software)
configurable rise fall delay time relay:
0 60 s (via software)
configuration options:
DIP switch || WAGO Interface Configuration Software || WAGO Interface Configuration App || WAGO Configuration Display
conformity marking:
CE
connection technology:
Push-in CAGE CLAMP
contact material relay:
AgNi + Au
continuous current do max:
100 mA (no internal restriction)
country of origin sales organisation germany:
DE
depth from upper edge of din rail:
107 mm / 4.213 inch
dielectric strength open contact ac 1 min:
1 kVrms
drop out time typ:
4 ms
emc emission of interference:
EN 61000-6-4: EN 61326-2-3: EN 50121-3-2
emc immunity to interference:
EN 61000-6-2: EN 61326-2-3: EN 50121-3-2
feedthrough for measurement conductor:
9.5 mm
fine stranded conductor:
0.2 2.5 mm / 24 12 AWG
fire load:
1.644 MJ
frequency range:
15 1000 Hz
height:
105 mm / 4.134 inch
input current max:
100 A AC/DC
input signal current:
AC 0.5 100 A DC 100 A
input signal type:
Current
insulation type analog output service interface:
Basic insulation
insulation type measurement circuit relay output supply analog output and service interface:
Double insulation
insulation type relay output supply analog output and service interface:
Reinforced insulation
limit frequency:
3.3 kHz
limiting continuous current relay module assembly:
6 A (¤ 60 C): 3 A (60 70 C)
line to neutral conductor voltage ac max:
300 V
load impedance current output:
¤ 600
load impedance voltage output:
1 k
measurement method:
True RMS measurement: Arithmetic mean value
mounting type:
DIN-35 rail
nominal supply voltage us:
DC 24 V
note:
This product is supplied with 24 VDC, which can be commoned using lateral push-in type jumper bars: (6.1) US+ (BR) and (6.2) GND 2 (BR). With this variant, it is necessary to ensure that the maximum permissible total current of 2 A is not exceeded.Ad
number of changeover switchover contacts:
1
number of switching thresholds do:
1 or 2 (adjustable)
number of switching thresholds relay:
1 or 2 (adjustable)
output signal current:
10 mA: 0 10 mA: 2 10 mA: 20 mA: 0 20 mA: 4 20 mA
output signal type:
Current || Voltage
output signal voltage:
5 V: 0 5 V: 1 5 V: 10 V: 0 10 V: 2 10 V
overvoltage category:
II
packaging type:
Bag
pollution degree:
2
power consumption at nominal supply voltage:
¤ 50 mA (+ IDO)
power supply type:
24 VDC
pull in time typ:
8 ms
resolution current:
10 mA
response threshold:
500 mA (AC): 250 mA (DC)
software filter adjustable:
Moving average value (filter level: 30)
solid conductor:
0.2 2.5 mm / 24 12 AWG
standards specifications:
EN 61010-1 || EN 61373
step response typ:
60 ms (DC: for software filter 3/default setting): 250 ms (AC)
strip length:
9 10 mm / 0.35 0.39 inch
supply voltage range:
30 %
surrounding air temperature operation:
-40 70 C
surrounding air temperature storage:
-40 85 C
switching voltage do max:
Supply voltage (applied): 0.3 V
switching voltage max:
AC 250 V
temperature coefficient:
¤ 0.01 %/K
temperature range of connecting cable per ul 61010 2 201 min:
90 C
temperature range of the connecting cable according to en 61010 2 201:
(Tsurrounding air + 10 K)
test voltage analog output service interface:
2 kVAC: 50 60 Hz: 1 min
test voltage input output supply:
AC 3 kV: 50 Hz: 1 min
test voltage measurement circuit relay output supply analog output:
3 kVAC: 50 60 Hz: 1 min
transmission error max:
¤ 1 % (of the full scale value)
wago connector:
picoMAX 5.0
weight:
102.939 g
width:
22.5 mm / 0.886 inch
  • Wago 2857-550
  • Wago 2857-550
  • Wago 2857-550
  • Wago 2857-550
  • Wago 2857-550
$745.70

Description

  • Both digital signal output and relay with changeover contact react to configured measuring range limits (switching ON/OFF delay and threshold value switch function configurable with up to two threshold values).
  • Clipping capability provides analog signal limitation to output end values.
  • Adjustable software filter
  • Input/Output response simulation via configuration display
  • Safe 3-way isolation with 3 kV test voltage per EN 61010-1
View AllClose