- baud rate:
- 10 kBd 1 MBd
- bus segment length max:
- 1000 m
- cob id distribution:
- SDO, standard
- color:
- Light gray
- communication:
- CANopen
- communication profile:
- DS-301 V4.1
- conformity marking:
- CE
- connection technology communication fieldbus:
- CANopen: 1 x Male connector: 5-pole
- connection technology device configuration:
- 1 x Male connector: 4-pole
- connection technology field supply:
- 6 x CAGE CLAMP
- connection technology system supply:
- 2 x CAGE CLAMP
- connection type 1:
- System/field supply
- country of origin sales organisation germany:
- DE
- current carrying capacity power jumper contacts:
- 0.416666666666667
- depth:
- 71.1 mm / 2.799 inch
- depth from upper edge of din rail:
- 63.9 mm / 2.516 inch
- device profile:
- DS-401 V2.0 || Limit value monitoring || Edge-triggered PDOs || Configurable response in the event of an error
- emc emission of interference:
- Per EN 61000-6-4, marine applications
- emc immunity to interference:
- Per EN 61000-6-2, marine applications
- exposure to pollutants:
- Per IEC 60068-2-42 and IEC 60068-2-43
- fine stranded conductor:
- 0.08 2.5 mm / 28 14 AWG
- fire load:
- 3.017 MJ
- height:
- 100 mm / 3.937 inch
- housing material:
- Polycarbonate: polyamide 6.6
- input and output fieldbus process image max:
- 512 Byte/512 Byte
- input current typ at nominal load 24 v:
- 500 mA
- isolation:
- 500 V system/field
- mounting position:
- Horizontal (standing/lying): vertical
- mounting type:
- DIN-35 rail
- node id distribution:
- DIP switch
- note:
- Note: Configuration files required (EDS)!
- number of fieldbus nodes on master max:
- 110
- number of modules per node max:
- 64
- number of outgoing power jumper contacts:
- 3
- number of pdos:
- 32 Tx / 32 Rx
- number of sdos:
- 2 SDO servers
- operating altitude:
- 0 2000 m
- other canopen features:
- NMT slave || Minimum boot-up || Variable PDO mapping || Emergency message || Life guarding || Virtual module configuration
- packaging type:
- Box
- permissible h2s contaminant concentration at a relative humidity 75:
- 10 ppm
- permissible so2 contaminant concentration at a relative humidity 75:
- 25 ppm
- pollution degree 5:
- 2 per IEC 61131-2
- power consumption 5 v system supply:
- 350 mA
- power supply efficiency typ at nominal load 24 v:
- 0.87
- protection type:
- IP20
- relative humidity without condensation:
- 0.95
- shock resistance:
- 15g per IEC 60068-2-27
- solid conductor:
- 0.08 2.5 mm / 28 14 AWG
- strip length:
- 8 9 mm / 0.31 0.35 inch
- supply voltage field:
- 24 VDC (-25 +30 %): via power jumper contacts
- supply voltage system:
- 24 VDC (-25 +30 %): via pluggable connector (CAGE CLAMP connection)
- surrounding air temperature operation:
- 0 55 C
- surrounding air temperature storage:
- -40 85 C
- total current system supply:
- 1650 mA
- transmission medium:
- Shielded Cu cable 3 x 0.25 mm
- vibration resistance:
- 4g per IEC 60068-2-6
- weight:
- 184.000 g
- width:
- 50.5 mm / 1.988 inch