calculated values:
Line-to-line voltage, power output, energy, power factors, mains frequency, harmonic analysis (up to the 41st harmonic), THD
color:
Light gray
conformity marking:
CE
connection technology inputs outputs:
16 x CAGE CLAMP
connection type 1:
Inputs/outputs
country of origin sales organisation germany:
DE
current path input resistance typ:
44 k
data width:
2 x 128-bit data: 2 x 64-bit control/status
depth:
67.8 mm / 2.669 inch
depth from upper edge of din rail:
60.6 mm / 2.386 inch
emc emission of interference:
Per EN 61000-6-3
emc immunity to interference:
Per EN 61000-6-2
exposure to pollutants:
Per IEC 60068-2-42 and IEC 60068-2-43
fine stranded conductor:
0.08 2.5 mm / 28 14 AWG
fire load:
1.687 MJ
frequency range harmonics analysis:
0 3300 Hz
frequency range mains frequency:
45 65 Hz
height:
100 mm / 3.937 inch
housing material:
Polycarbonate: polyamide 6.6
isolation:
6 kV (system/field)
limit frequency:
15.9 kHz
measurement components:
Evaluating
measurement current max:
Rogowski Coils RT500/RT2000
measurement cycle time:
Adjustable for arithmetic mean value, Min_Max_Values
measurement error deviation max from the upper range value:
0.005
measurement error reference temperature:
25 C
measurement method:
True RMS measurement
mounting position:
Horizontal (standing/lying): vertical
mounting type:
DIN-35 rail
number of measurement inputs:
7 (3 Spannungsmesseing¤nge, 4 differentielle Strommesseing¤nge)
operating altitude:
0 2000 m
packaging type:
Box
permissible h2s contaminant concentration at a relative humidity 75:
10 ppm
permissible so2 contaminant concentration at a relative humidity 75:
25 ppm
pollution degree 5:
2
power consumption 5 v system supply:
100 mA
protection type:
IP20
rated surge voltage:
6 kV
rated voltage:
VLN = 400 VAC: VLL = 690 VAC
reference for measurement error:
AC current/voltage
relative humidity without condensation:
0.95
resolution bit:
24 bits
shock resistance:
15g per IEC 60068-2-27
signal form:
Any periodic signals (considering the threshold frequencies)
signal type:
Power measurement
solid conductor:
0.08 2.5 mm / 28 14 AWG
strip length:
8 9 mm / 0.31 0.35 inch
supply voltage system:
5 VDC: via data contacts
surrounding air temperature operation:
0 55 C
surrounding air temperature storage:
-40 85 C
vibration resistance:
4g per IEC 60068-2-6
voltage path input resistance typ:
1429 k
weight:
98.111 g
width:
24 mm / 0.945 inch