WAGO 750-8212/000-100 PFC200 G2 BACnet/IP Controller, Native B-BC, Hazardous Area & Marine Approved
WagoWAGO PFC200 G2 with Native BACnet/IP (750-8212/000-100)
The WAGO 750-8212/000-100 is the BACnet/IP variant of the PFC200 2nd Generation Controller — a compact PLC purpose-configured for building automation, HVAC plant, energy management, and process applications where BACnet/IP is the primary fieldbus. It implements the full B-BC (BACnet Building Controller) device profile per ISO 16484-5, BACnet revision 14, with native protocol support that does not require an additional license — the BACnet stack and the WAGO BACnet Configurator tool ship with the controller.
Underneath the BACnet stack, the 750-8212/000-100 is a full-featured PFC200 G2 PLC: an ARM Cortex-A8 1 GHz CPU with 512 MB RAM and 4 GB internal flash, real-time Linux operating system (PREEMPT_RT patch), and IEC 61131-3 programming in CODESYS V3.5 (firmware release 23 and higher) or legacy e!COCKPIT (up to firmware release 22). It runs Modbus TCP/UDP/RTU master and slave, EtherNet/IP™ adapter and scanner, EtherCAT® master, OPC UA server/client, OPC UA Pub/Sub, MQTT, and supports IEC 60870, IEC 61850, and DNP3 telecontrol via license — all alongside BACnet on the same controller.
The 750-8212/000-100 carries an unusually broad set of approvals for a building controller: UL Hazardous Locations (E198726), ATEX, IECEx, UKEx, CCCEx, and INMETRO for Zone 2 hazardous gas atmospheres, plus BSH, DNV, and PRS for marine and shipboard installations — making it a strong fit not just for commercial HVAC, but for chemical plant utilities, refinery building services, water/wastewater plant rooms, and shipboard HVAC where BACnet integration is required.
Most "BACnet-capable" PLCs are gateway-style retrofits. The 750-8212/000-100 implements the full B-BC profile natively, presenting BACnet objects directly from the controller program. Use the included WAGO BACnet Configurator to map AI/AO/BI/BO/AV/BV objects, schedules, calendars, trend logs, and notification classes — then commission directly with any BACnet/IP supervisory tool. A dedicated BT (BACnet) status LED gives you protocol-level diagnostics at a glance.
Need BACnet-aware HVAC, lighting, or utility control inside a Class I Division 2 / Zone 2 area, or on a classed vessel? Most building controllers can’t be specified there. The 750-8212/000-100 carries UL HazLoc, ATEX, IECEx, UKEx, CCCEx, INMETRO Zone 2 approvals plus BSH, DNV, and PRS marine certifications — while still running the same BACnet, Modbus, and OPC UA stacks as a standard plant controller.
When to Specify 750-8212/000-100 vs. Standard 750-8212
The standard WAGO 750-8212 can run BACnet/IP via a separately licensed runtime, but the 750-8212/000-100 ships with BACnet/IP active out of the box, includes the dedicated B-BC firmware build, and adds the hazardous-area and marine approvals that the base SKU does not carry. If your specification calls out BACnet/IP — or your installation is in a Zone 2 hazardous area or on a classed vessel — this is the right SKU.
| Specification | Standard 750-8212 | 750-8212/000-100 (BACnet/IP) |
|---|---|---|
| BACnet/IP support | Available via separate license | Native; B-BC profile, BACnet revision 14 |
| BACnet Configurator tool | Available with license | Included; integrated firmware build |
| BACnet status LED (BT) | Generic user LED only | Dedicated BT diagnostic LED |
| UL Hazardous Locations | Ordinary Locations only | UL 121201 / E198726 (Zone 2) |
| ATEX / IECEx / UKEx | ATEX / IECEx | ATEX, IECEx, UKEx, CCCEx, INMETRO |
| Marine approvals | Pending | BSH (1104), DNV (TAA0000194), PRS |
| Best for | General machine and equipment control | HVAC/BAS, building services, hazardous-area utilities, marine HVAC |
BACnet/IP Capabilities
- ISO 16484-5
- B-BC (BACnet Building Controller)
- BACnet Revision 14
- Native BACnet/IP on 2 x RJ-45
- BACnet stack runs on the PLC, not via a gateway
- Analog & Binary Input/Output/Value
- Multi-State objects
- Schedules & Calendars
- Notification Class & Event Enrollment
- Trend Log & Trend Log Multiple
- WAGO BACnet Configurator
- WAGO Solution Builder (HVAC macros)
- BACnet PICS available for spec compliance
- HVAC BACnet Macro library
- Web-Based Management (WBM)
All Other Protocols, On the Same Controller
The 750-8212/000-100 doesn’t make BACnet your only option — it adds BACnet on top of the full PFC200 G2 protocol stack. This is what makes it useful as a unified building/process controller: the same device that talks BACnet to your HVAC and lighting can also speak Modbus to your water meters, EtherNet/IP to your packaged chillers, and OPC UA to the plant historian.
- BACnet/IP (native)
- Modbus TCP master/slave
- Modbus UDP & RTU
- EtherNet/IP™ scanner & adapter
- EtherCAT® master
- OPC UA server / client
- OPC UA Pub/Sub (later install)
- MQTT
- HTTP / HTTPS / SSH
- FTP / FTPS / SNMP
- RS-232 & RS-485 serial
- IEC 60870 (license)
- IEC 61850 client/server (license)
- DNP3 master/slave (license)
- SNMP, NTP, DNS, DHCP
Typical Applications
Air-handling units, chiller plant control, VAV/VRF coordination, lighting and shading schedules, energy sub-metering, with BACnet/IP as the supervisory protocol back to the BMS head-end.
Plant utility air handlers, compressed air management, dust collection, process exhaust, and clean-room HVAC where BAS protocols meet plant Modbus and EtherNet/IP networks.
Refinery and chemical-plant motor control centers, lab and pilot-plant rooms, oil & gas pump-house HVAC. Zone 2 / Class I Division 2 approvals open up locations where standard BAS controllers can’t be installed.
Shipboard accommodation HVAC, engine-room ventilation, ballast/bilge ancillary control, offshore platform building systems — supported by BSH, DNV, and PRS classification approvals.
Aggregate Modbus electricity, gas, and water meters into BACnet objects for the BMS. Use OPC UA Pub/Sub or MQTT to publish the same data to enterprise sustainability and energy-management platforms.
Plant utility rooms, chemical dosing rooms (Zone 2), pump-house HVAC, with DNP3 telecontrol licensing available for SCADA integration alongside BACnet for the building services side.
Technical Specifications
| Processor & Memory | |
| CPU | ARM Cortex-A8, 1 GHz |
| Operating System | Real-time Linux (PREEMPT_RT patch) |
| Main Memory (RAM) | 512 MB |
| Internal Flash | 4 GB (4096 MB) |
| Program Memory | 32 MB |
| Data Memory | 128 MB |
| Non-Volatile (HW / SW) | 128 KB / 128 KB |
| Memory Card Slot | SD / SDHC up to 32 GB, push-push, sealable cover |
| Real-Time Clock Drift / Backup | 3 ppm @ 25 °C; 30-day backup |
| BACnet Capability | |
| Protocol | BACnet/IP per ISO 16484-5 |
| Device Profile | B-BC (BACnet Building Controller) |
| BACnet Revision | 14 |
| Tooling | WAGO BACnet Configurator (included); WAGO Solution Builder; HVAC BACnet Macros |
| Programming & Configuration | |
| Programming Environment | CODESYS V3.5 (firmware release 23 and higher); e!COCKPIT (up to firmware release 22) |
| IEC 61131-3 Languages | IL, LD, FBD, CFC, ST, SFC |
| Configuration Tools | CODESYS V3, e!COCKPIT, WAGO-I/O-CHECK, Web-Based Management |
| Interfaces & I/O | |
| Ethernet | 2 x RJ-45 (BACnet/IP, Modbus TCP/UDP), 10/100 Mbit/s with integrated switch |
| Serial Interfaces | 1 x D-sub 9 (Modbus RTU, RS-232, RS-485 share the same connector) |
| Service Port | 1 x 4-pin male connector (configuration) |
| I/O Modules per Node | Up to 250 (max. 64 without bus extension) |
| Process Image (Modbus) | CODESYS V3: 32,000 words input / 32,000 words output |
| Indicators | SYS, RUN, I/O, BT (BACnet), U1–U6 (red/green/orange); A, B status LEDs (green) |
| Power Supply | |
| Supply Voltage (System) | 24 VDC (−25 / +30 %), 2 x CAGE CLAMP® |
| Supply Voltage (Field) | 24 VDC, via power jumper contacts; 6 x CAGE CLAMP® |
| Input Current (typ., 24 V) | 550 mA |
| Total System Current | 1,700 mA |
| Power Jumper Capacity | 10 A (3 outgoing contacts) |
| Isolation | 500 V system / field |
| Physical & Environmental | |
| Dimensions (W x H x D) | 78.6 x 100 x 71.9 mm (3.094 x 3.937 x 2.831 in) |
| Weight | 215.4 g |
| Mounting | DIN-35 rail, any orientation |
| Housing Material / Color | Polycarbonate, polyamide 6.6 / light gray |
| Operating Temperature | 0 to +55 °C |
| Storage Temperature | −25 to +85 °C |
| Protection Class | IP20 |
| Vibration / Shock | 4g per IEC 60068-2-6 / 15g per IEC 60068-2-27 |
| Operating Altitude | 0–2,000 m without derating; up to 5,000 m with derating |
| Approvals & Compliance | |
| General | CE, UL Ordinary Locations (E175199), EAC CoC 03083, KC MSIP-REM-W43-PFC750 |
| Hazardous Areas | UL HazLoc UL 121201 (E198726), ATEX (TUEV14ATEX148929X, II 3 G Ex ec IIC T4 Gc), IECEx TUN 14.0035 X, UKEx GO22UKEX003X, CCCEx 2020312310000213, INMETRO TÜV 12.1297 X |
| Marine | BSH 1104, DNV TAA0000194 (DNV-CG-0339), PRS TE/1101/880590/23 |
| EMC | EN 61000-6-2 immunity, EN 61000-6-3 emission (marine applications) |
| RoHS | Compliant, no exemption |
What’s Included — and What to Order Separately
The 750-8212/000-100 ships as a single controller (PU = 1 pc, boxed) with the BACnet/IP firmware, native BACnet stack, integrated WAGO Webserver, real-time Linux OS, and CODESYS V3.5 / e!COCKPIT runtime active out of the box. Specify the following as your project requires:
| Accessory | WAGO Item No. | Notes |
|---|---|---|
| SD Memory Card (2 GB SLC NAND) | 758-879/000-001 | −40 to +90 °C industrial-grade card; required for guaranteed properties |
| SD Memory Card (8 GB pSLC-NAND) | 758-879/000-2108 | −40 to +90 °C, larger capacity for trend logging |
| Bus End Module | 750-600 | Required to terminate the I/O node |
| Configuration Cable (USB) | 750-923 | 2.5 m service cable for the configuration port |
| Telecontrol Runtime Licenses | 2759-2293/-2290/-293/-290/-2243/-2240 | DNP3, IEC 60870, IEC 61850 (master/slave/client/server) — sold per controller |
Note: Use only WAGO-recommended SD cards. External overcurrent protection (max. 2 A slow-blow on system supply, max. 10 A on field supply) is required per the WAGO 750/753 system manual. Hazardous-area installations must follow the conditions of the relevant ATEX, IECEx, UKEx, CCCEx, INMETRO or UL HazLoc certificate; consult the certificate text and local authority having jurisdiction.
Frequently Asked Questions
Automation Distribution carries the complete WAGO PFC200 G2 lineup — from the standard 750-8212, the /025-001 and /025-002 telecontrol variants, the /040-010 Extreme, to this BACnet/IP variant (750-8212/000-100) — plus the entry-level PFC100 and the next-generation PFC300 family. Our applications team can help you select the right controller for your BAS, hazardous-area, or marine project.
Call 1-888-600-3080 or visit automationdistribution.com/wago-controllers-bus-couplers-and-i-o to request a quote on the WAGO 750-8212/000-100 today.
- baud rate:
- ETHERNET: 10/100 Mbit/s
- baud rate communication fieldbus 1:
- 10/100 Mbit/s
- Color:
- Light Gray
- communication:
- BACnet/IP || Modbus (TCP, UDP) || ETHERNET || EtherNet/IPTM Adapter (slave), library for e!RUNTIME || Modbus RTU || RS-232 serial interface || RS-485 serial interface || MQTT || EtherCAT Master, requires an additional license
- configuration options:
- e!COCKPIT || WAGO-I/O-CHECK || Web-Based Management || e!RUNTIME Library || CODESYS Library
- connection technology communication fieldbus:
- BACnet/IP: 2 x RJ-45: Modbus TCP/UDP: 2 x RJ-45: Modbus RTU: 1 x D-sub 9 socket: RS-232 serial interface: 1 x D-sub 9 socket: RS-485 serial interface: 1 x D-sub 9 socket
- connection technology device configuration:
- 1 x Male connector: 4-pole
- connection technology field supply:
- 6 x CAGE CLAMP
- connection technology system supply:
- 2 x CAGE CLAMP
- connection type 1:
- System/field supply
- country of origin sales organisation germany:
- DE
- cpu:
- Cortex A8: 1 GHz
- current carrying capacity power jumper contacts:
- 0.416666666666667
- data memory:
- 128 MB
- depth:
- 71.9 mm / 2.831 inch
- depth from upper edge of din rail:
- 64.7 mm / 2.547 inch
- device specific:
- BACnet/IP protocol: ISO 16484-5: BACnet device profile: B-BC (BACnet Building Controller): BACnet revision: 14
- emc emission of interference:
- Per EN 61000-6-3, marine applications
- emc immunity to interference:
- Per EN 61000-6-2, marine applications
- ethernet protocols:
- DHCP || DNS || NTP || FTP || FTPS || SNMP || HTTP || HTTPS || SSH
- exposure to pollutants:
- Per IEC 60068-2-42 and IEC 60068-2-43
- fine stranded conductor:
- 0.08 2.5 mm / 28 14 AWG
- fire load:
- 2.346 MJ
- height:
- 100 mm / 3.937 inch
- housing material:
- Polycarbonate: polyamide 6.6
- indicators:
- LED (SYS: RUN: I/O: BT: U1 U6) red/green/orange: Status of system: program: local data bus: BACnet: status programmable by user (can be used via CODESYS library): LED (A, B) green: Status of system power supply: field supply
- input and output internal process image max:
- 1000 Worte/1000 Worte
- input and output modbus process image max:
- e!RUNTIME: 32000 Worte/32000 Worte
- input current typ at nominal load 24 v:
- 550 mA
- internal memory flash:
- 4096 MB
- isolation:
- 500 V system/field
- main memory ram:
- 512 MB
- memory card slot:
- Push-push mechanism: Cover lid (sealable)
- memory card type:
- SD and SDHC up to 32 GB (all guaranteed properties only valid with WAGO 758-879/000-001 Memory Card)
- mounting position:
- Any
- mounting type:
- DIN-35 rail
- non volatile hardware memory:
- 128 kB
- non volatile software memory:
- 128 kB
- number of modules per node max:
- 250
- number of modules without a bus extension max:
- 64
- number of outgoing power jumper contacts:
- 3
- operating altitude:
- Without temperature derating: 0 2000 m: with temperature derating: 2000 5000 m (0.5 K/100 m): 5000 m (max.)
- operating system:
- Real-time Linux (with RT-Preempt patch)
- packaging type:
- Box
- permissible h2s contaminant concentration at a relative humidity 75:
- 10 ppm
- permissible so2 contaminant concentration at a relative humidity 75:
- 25 ppm
- pollution degree 5:
- 2 per IEC 61131-2
- program memory:
- 32 MB
- programming environment:
- e!COCKPIT (based on CODESYS V3)
- programming languages per iec 61131 3:
- Instruction List (IL) || Ladder Diagram (LD) || Function Block Diagram (FBD), Continuous Function Chart (CFC) || Structured Text (ST) || Sequential Function Chart (SFC)
- protection type:
- IP20
- relative humidity without condensation:
- 0.95
- shock resistance:
- 15g per IEC 60068-2-27
- solid conductor:
- 0.08 2.5 mm / 28 14 AWG
- strip length:
- 8 9 mm / 0.31 0.35 inch
- supply voltage field:
- 24 VDC (-25 +30 %): via power jumper contacts
- supply voltage system:
- 24 VDC (-25 +30 %): via pluggable connector (CAGE CLAMP connection)
- surrounding air temperature operation:
- 0 55 C
- surrounding air temperature storage:
- -25 85 C
- total current system supply:
- 1700 mA
- transmission medium communication fieldbus:
- ETHERNET: Twisted Pair S-UTP: 100 : Cat. 5: 100 m maximum cable length
- vibration resistance:
- 4g per IEC 60068-2-6
- visualization:
- Web Visu
- weight:
- 214.928 g
- width: