WAGO 750-8212/000-100 PFC200 G2 BACnet/IP Controller, Native B-BC, Hazardous Area & Marine Approved

Wago
SKU:
750-8212/000-100
Availability:
Factory stock
$2,536.00
Condition:
New
Current Stock:
NATIVE BACnet/IP
B-BC PROFILE · REV. 14
CODESYS V3.5 / e!COCKPIT
ATEX / IECEx / UL Zone 2
DNV / BSH MARINE

WAGO PFC200 G2 with Native BACnet/IP (750-8212/000-100)

The WAGO 750-8212/000-100 is the BACnet/IP variant of the PFC200 2nd Generation Controller — a compact PLC purpose-configured for building automation, HVAC plant, energy management, and process applications where BACnet/IP is the primary fieldbus. It implements the full B-BC (BACnet Building Controller) device profile per ISO 16484-5, BACnet revision 14, with native protocol support that does not require an additional license — the BACnet stack and the WAGO BACnet Configurator tool ship with the controller.

Underneath the BACnet stack, the 750-8212/000-100 is a full-featured PFC200 G2 PLC: an ARM Cortex-A8 1 GHz CPU with 512 MB RAM and 4 GB internal flash, real-time Linux operating system (PREEMPT_RT patch), and IEC 61131-3 programming in CODESYS V3.5 (firmware release 23 and higher) or legacy e!COCKPIT (up to firmware release 22). It runs Modbus TCP/UDP/RTU master and slave, EtherNet/IP™ adapter and scanner, EtherCAT® master, OPC UA server/client, OPC UA Pub/Sub, MQTT, and supports IEC 60870, IEC 61850, and DNP3 telecontrol via license — all alongside BACnet on the same controller.

The 750-8212/000-100 carries an unusually broad set of approvals for a building controller: UL Hazardous Locations (E198726), ATEX, IECEx, UKEx, CCCEx, and INMETRO for Zone 2 hazardous gas atmospheres, plus BSH, DNV, and PRS for marine and shipboard installations — making it a strong fit not just for commercial HVAC, but for chemical plant utilities, refinery building services, water/wastewater plant rooms, and shipboard HVAC where BACnet integration is required.

FOR BAS / HVAC ENGINEERS
A Real BACnet Controller, Not a Gateway

Most "BACnet-capable" PLCs are gateway-style retrofits. The 750-8212/000-100 implements the full B-BC profile natively, presenting BACnet objects directly from the controller program. Use the included WAGO BACnet Configurator to map AI/AO/BI/BO/AV/BV objects, schedules, calendars, trend logs, and notification classes — then commission directly with any BACnet/IP supervisory tool. A dedicated BT (BACnet) status LED gives you protocol-level diagnostics at a glance.

FOR PROCESS & MARINE ENGINEERS
Building Control Where Other PLCs Can’t Go

Need BACnet-aware HVAC, lighting, or utility control inside a Class I Division 2 / Zone 2 area, or on a classed vessel? Most building controllers can’t be specified there. The 750-8212/000-100 carries UL HazLoc, ATEX, IECEx, UKEx, CCCEx, INMETRO Zone 2 approvals plus BSH, DNV, and PRS marine certifications — while still running the same BACnet, Modbus, and OPC UA stacks as a standard plant controller.

When to Specify 750-8212/000-100 vs. Standard 750-8212

The standard WAGO 750-8212 can run BACnet/IP via a separately licensed runtime, but the 750-8212/000-100 ships with BACnet/IP active out of the box, includes the dedicated B-BC firmware build, and adds the hazardous-area and marine approvals that the base SKU does not carry. If your specification calls out BACnet/IP — or your installation is in a Zone 2 hazardous area or on a classed vessel — this is the right SKU.

SpecificationStandard 750-8212750-8212/000-100 (BACnet/IP)
BACnet/IP support Available via separate license Native; B-BC profile, BACnet revision 14
BACnet Configurator tool Available with license Included; integrated firmware build
BACnet status LED (BT) Generic user LED only Dedicated BT diagnostic LED
UL Hazardous Locations Ordinary Locations only UL 121201 / E198726 (Zone 2)
ATEX / IECEx / UKEx ATEX / IECEx ATEX, IECEx, UKEx, CCCEx, INMETRO
Marine approvals Pending BSH (1104), DNV (TAA0000194), PRS
Best for General machine and equipment control HVAC/BAS, building services, hazardous-area utilities, marine HVAC

BACnet/IP Capabilities

Standards & Profiles
  • ISO 16484-5
  • B-BC (BACnet Building Controller)
  • BACnet Revision 14
  • Native BACnet/IP on 2 x RJ-45
  • BACnet stack runs on the PLC, not via a gateway
Object Types Supported
  • Analog & Binary Input/Output/Value
  • Multi-State objects
  • Schedules & Calendars
  • Notification Class & Event Enrollment
  • Trend Log & Trend Log Multiple
Engineering Tools
  • WAGO BACnet Configurator
  • WAGO Solution Builder (HVAC macros)
  • BACnet PICS available for spec compliance
  • HVAC BACnet Macro library
  • Web-Based Management (WBM)

All Other Protocols, On the Same Controller

The 750-8212/000-100 doesn’t make BACnet your only option — it adds BACnet on top of the full PFC200 G2 protocol stack. This is what makes it useful as a unified building/process controller: the same device that talks BACnet to your HVAC and lighting can also speak Modbus to your water meters, EtherNet/IP to your packaged chillers, and OPC UA to the plant historian.

Industrial Ethernet
  • BACnet/IP (native)
  • Modbus TCP master/slave
  • Modbus UDP & RTU
  • EtherNet/IP™ scanner & adapter
  • EtherCAT® master
IIoT & Information
  • OPC UA server / client
  • OPC UA Pub/Sub (later install)
  • MQTT
  • HTTP / HTTPS / SSH
  • FTP / FTPS / SNMP
Telecontrol & Serial
  • RS-232 & RS-485 serial
  • IEC 60870 (license)
  • IEC 61850 client/server (license)
  • DNP3 master/slave (license)
  • SNMP, NTP, DNS, DHCP

Typical Applications

Commercial HVAC & BAS

Air-handling units, chiller plant control, VAV/VRF coordination, lighting and shading schedules, energy sub-metering, with BACnet/IP as the supervisory protocol back to the BMS head-end.

Industrial Plant Utilities

Plant utility air handlers, compressed air management, dust collection, process exhaust, and clean-room HVAC where BAS protocols meet plant Modbus and EtherNet/IP networks.

Hazardous-Area Building Services

Refinery and chemical-plant motor control centers, lab and pilot-plant rooms, oil & gas pump-house HVAC. Zone 2 / Class I Division 2 approvals open up locations where standard BAS controllers can’t be installed.

Marine & Offshore HVAC

Shipboard accommodation HVAC, engine-room ventilation, ballast/bilge ancillary control, offshore platform building systems — supported by BSH, DNV, and PRS classification approvals.

Energy & Sub-Metering

Aggregate Modbus electricity, gas, and water meters into BACnet objects for the BMS. Use OPC UA Pub/Sub or MQTT to publish the same data to enterprise sustainability and energy-management platforms.

Water & Wastewater Plant Buildings

Plant utility rooms, chemical dosing rooms (Zone 2), pump-house HVAC, with DNP3 telecontrol licensing available for SCADA integration alongside BACnet for the building services side.

Technical Specifications

Processor & Memory
CPU ARM Cortex-A8, 1 GHz
Operating System Real-time Linux (PREEMPT_RT patch)
Main Memory (RAM) 512 MB
Internal Flash 4 GB (4096 MB)
Program Memory 32 MB
Data Memory 128 MB
Non-Volatile (HW / SW) 128 KB / 128 KB
Memory Card Slot SD / SDHC up to 32 GB, push-push, sealable cover
Real-Time Clock Drift / Backup 3 ppm @ 25 °C; 30-day backup
BACnet Capability
Protocol BACnet/IP per ISO 16484-5
Device Profile B-BC (BACnet Building Controller)
BACnet Revision 14
Tooling WAGO BACnet Configurator (included); WAGO Solution Builder; HVAC BACnet Macros
Programming & Configuration
Programming Environment CODESYS V3.5 (firmware release 23 and higher); e!COCKPIT (up to firmware release 22)
IEC 61131-3 Languages IL, LD, FBD, CFC, ST, SFC
Configuration Tools CODESYS V3, e!COCKPIT, WAGO-I/O-CHECK, Web-Based Management
Interfaces & I/O
Ethernet 2 x RJ-45 (BACnet/IP, Modbus TCP/UDP), 10/100 Mbit/s with integrated switch
Serial Interfaces 1 x D-sub 9 (Modbus RTU, RS-232, RS-485 share the same connector)
Service Port 1 x 4-pin male connector (configuration)
I/O Modules per Node Up to 250 (max. 64 without bus extension)
Process Image (Modbus) CODESYS V3: 32,000 words input / 32,000 words output
Indicators SYS, RUN, I/O, BT (BACnet), U1–U6 (red/green/orange); A, B status LEDs (green)
Power Supply
Supply Voltage (System) 24 VDC (−25 / +30 %), 2 x CAGE CLAMP®
Supply Voltage (Field) 24 VDC, via power jumper contacts; 6 x CAGE CLAMP®
Input Current (typ., 24 V) 550 mA
Total System Current 1,700 mA
Power Jumper Capacity 10 A (3 outgoing contacts)
Isolation 500 V system / field
Physical & Environmental
Dimensions (W x H x D) 78.6 x 100 x 71.9 mm (3.094 x 3.937 x 2.831 in)
Weight 215.4 g
Mounting DIN-35 rail, any orientation
Housing Material / Color Polycarbonate, polyamide 6.6 / light gray
Operating Temperature 0 to +55 °C
Storage Temperature −25 to +85 °C
Protection Class IP20
Vibration / Shock 4g per IEC 60068-2-6 / 15g per IEC 60068-2-27
Operating Altitude 0–2,000 m without derating; up to 5,000 m with derating
Approvals & Compliance
General CE, UL Ordinary Locations (E175199), EAC CoC 03083, KC MSIP-REM-W43-PFC750
Hazardous Areas UL HazLoc UL 121201 (E198726), ATEX (TUEV14ATEX148929X, II 3 G Ex ec IIC T4 Gc), IECEx TUN 14.0035 X, UKEx GO22UKEX003X, CCCEx 2020312310000213, INMETRO TÜV 12.1297 X
Marine BSH 1104, DNV TAA0000194 (DNV-CG-0339), PRS TE/1101/880590/23
EMC EN 61000-6-2 immunity, EN 61000-6-3 emission (marine applications)
RoHS Compliant, no exemption

What’s Included — and What to Order Separately

The 750-8212/000-100 ships as a single controller (PU = 1 pc, boxed) with the BACnet/IP firmware, native BACnet stack, integrated WAGO Webserver, real-time Linux OS, and CODESYS V3.5 / e!COCKPIT runtime active out of the box. Specify the following as your project requires:

AccessoryWAGO Item No.Notes
SD Memory Card (2 GB SLC NAND) 758-879/000-001 −40 to +90 °C industrial-grade card; required for guaranteed properties
SD Memory Card (8 GB pSLC-NAND) 758-879/000-2108 −40 to +90 °C, larger capacity for trend logging
Bus End Module 750-600 Required to terminate the I/O node
Configuration Cable (USB) 750-923 2.5 m service cable for the configuration port
Telecontrol Runtime Licenses 2759-2293/-2290/-293/-290/-2243/-2240 DNP3, IEC 60870, IEC 61850 (master/slave/client/server) — sold per controller

Note: Use only WAGO-recommended SD cards. External overcurrent protection (max. 2 A slow-blow on system supply, max. 10 A on field supply) is required per the WAGO 750/753 system manual. Hazardous-area installations must follow the conditions of the relevant ATEX, IECEx, UKEx, CCCEx, INMETRO or UL HazLoc certificate; consult the certificate text and local authority having jurisdiction.

Frequently Asked Questions

What is the WAGO 750-8212/000-100?
The WAGO 750-8212/000-100 is the BACnet/IP variant of the PFC200 2nd Generation Controller. It is a compact PLC that runs native BACnet/IP per the B-BC (BACnet Building Controller) device profile, BACnet revision 14, alongside Modbus, EtherNet/IP, EtherCAT, OPC UA, and MQTT. The controller is built on an ARM Cortex-A8 1 GHz CPU with 512 MB RAM and 4 GB flash, runs real-time Linux with the PREEMPT_RT patch, and is programmed in CODESYS V3.5 (firmware release 23 and later) or e!COCKPIT (up to firmware release 22).
How is the 750-8212/000-100 different from the standard 750-8212?
The standard 750-8212 supports BACnet/IP via a separately licensed runtime, while the 750-8212/000-100 ships with the native B-BC BACnet stack and the WAGO BACnet Configurator out of the box. The /000-100 also adds a dedicated BT (BACnet) status LED for protocol-level diagnostics, plus a broader approvals package — UL Hazardous Locations (E198726), ATEX, IECEx, UKEx, CCCEx, INMETRO Zone 2, plus marine BSH, DNV, and PRS — that the standard 750-8212 does not carry.
What BACnet device profile does the controller support?
The 750-8212/000-100 implements the B-BC (BACnet Building Controller) profile per ISO 16484-5, BACnet revision 14. B-BC is the highest-functionality general-purpose BACnet controller profile and supports analog and binary input/output/value objects, multi-state objects, schedules, calendars, notification classes, event enrollment, and trend logs. Full BACnet PICS documentation is available from WAGO for spec compliance review.
Is the WAGO BACnet Configurator included?
Yes. The WAGO BACnet Configurator is the engineering tool used to define and map BACnet objects, schedules, calendars, trend logs, and notification classes from the controller program out to the BAS network. It is provided by WAGO at no additional cost for the 750-8212/000-100. The WAGO Solution Builder, with HVAC BACnet macro libraries, is also available to accelerate typical AHU and chiller programming.
Can I install this controller in a Class I, Division 2 / Zone 2 hazardous area?
Yes. The 750-8212/000-100 carries UL HazLoc certification (UL 121201 / E198726) for North American Class I Division 2 installations, plus ATEX (II 3 G Ex ec IIC T4 Gc), IECEx, UKEx, CCCEx, and INMETRO certifications for Zone 2 hazardous gas atmospheres internationally. Always consult the certificate text and your local authority having jurisdiction regarding enclosure selection, wiring methods, and any conditions of the certificate.
Is this controller approved for marine and shipboard installations?
Yes. The 750-8212/000-100 holds three classification society approvals: BSH (Bundesamt fuer Seeschifffahrt und Hydrographie), DNV (TAA0000194 per DNV-CG-0339, August 2021), and PRS (Polski Rejestr Statków). These approvals support shipboard accommodation HVAC, engine-room ventilation, ballast/bilge ancillary control, and offshore platform building services where BACnet integration is required.
Do I have to use BACnet, or can I use other protocols too?
Both. The /000-100 firmware adds BACnet/IP on top of the full PFC200 G2 protocol stack. The same controller can run BACnet to the BMS supervisory layer, Modbus TCP/RTU to meters and submeter panels, EtherNet/IP to packaged HVAC equipment, OPC UA to the plant historian or sustainability platform, and MQTT to a cloud broker — all simultaneously. This is the central reason to specify it as a unified building/plant controller rather than a single-protocol device.
Should I program in CODESYS V3.5 or e!COCKPIT?
For new projects, use CODESYS V3.5 with firmware release 23 or higher — this is the active development path for the PFC200 G2 family. e!COCKPIT (also based on CODESYS V3) is supported up to firmware release 22 and remains a valid environment for legacy projects, but new functionality is shipped on the CODESYS V3.5 path. WAGO publishes a Migration Guide for moving e!COCKPIT projects forward to CODESYS V3.5.
How many WAGO I/O modules can I connect?
Up to 250 modules per node total. Without a bus extension, you can connect up to 64 modules. The full WAGO 750/753 Series I/O catalog is supported — digital, analog, specialty, and serial communication modules — making the 750-8212/000-100 a drop-in upgrade path for existing 750/753 designs that need to add native BACnet capability.
Where do I buy the WAGO 750-8212/000-100 in the United States?
Automation Distribution is an authorized WAGO distributor based in Hatfield, PA, serving customers across the United States. We carry the full WAGO PFC200 G2 family including the standard 750-8212, the extreme-temperature 750-8212/040-010, and the telecontrol-enabled 750-8212/025-001 and /025-002 variants. Call 1-888-600-3080 or visit automationdistribution.com for pricing, availability, and engineering consultation on building automation deployments.
BACnet, hazardous-area, and marine-rated — on one controller.

Automation Distribution carries the complete WAGO PFC200 G2 lineup — from the standard 750-8212, the /025-001 and /025-002 telecontrol variants, the /040-010 Extreme, to this BACnet/IP variant (750-8212/000-100) — plus the entry-level PFC100 and the next-generation PFC300 family. Our applications team can help you select the right controller for your BAS, hazardous-area, or marine project.

Call 1-888-600-3080 or visit automationdistribution.com/wago-controllers-bus-couplers-and-i-o to request a quote on the WAGO 750-8212/000-100 today.

 

 

baud rate:
ETHERNET: 10/100 Mbit/s
baud rate communication fieldbus 1:
10/100 Mbit/s
Color:
Light Gray
communication:
BACnet/IP || Modbus (TCP, UDP) || ETHERNET || EtherNet/IPTM Adapter (slave), library for e!RUNTIME || Modbus RTU || RS-232 serial interface || RS-485 serial interface || MQTT || EtherCAT Master, requires an additional license
configuration options:
e!COCKPIT || WAGO-I/O-CHECK || Web-Based Management || e!RUNTIME Library || CODESYS Library
connection technology communication fieldbus:
BACnet/IP: 2 x RJ-45: Modbus TCP/UDP: 2 x RJ-45: Modbus RTU: 1 x D-sub 9 socket: RS-232 serial interface: 1 x D-sub 9 socket: RS-485 serial interface: 1 x D-sub 9 socket
connection technology device configuration:
1 x Male connector: 4-pole
connection technology field supply:
6 x CAGE CLAMP
connection technology system supply:
2 x CAGE CLAMP
connection type 1:
System/field supply
country of origin sales organisation germany:
DE
cpu:
Cortex A8: 1 GHz
current carrying capacity power jumper contacts:
0.416666666666667
data memory:
128 MB
depth:
71.9 mm / 2.831 inch
depth from upper edge of din rail:
64.7 mm / 2.547 inch
device specific:
BACnet/IP protocol: ISO 16484-5: BACnet device profile: B-BC (BACnet Building Controller): BACnet revision: 14
emc emission of interference:
Per EN 61000-6-3, marine applications
emc immunity to interference:
Per EN 61000-6-2, marine applications
ethernet protocols:
DHCP || DNS || NTP || FTP || FTPS || SNMP || HTTP || HTTPS || SSH
exposure to pollutants:
Per IEC 60068-2-42 and IEC 60068-2-43
fine stranded conductor:
0.08 2.5 mm / 28 14 AWG
fire load:
2.346 MJ
height:
100 mm / 3.937 inch
housing material:
Polycarbonate: polyamide 6.6
indicators:
LED (SYS: RUN: I/O: BT: U1 U6) red/green/orange: Status of system: program: local data bus: BACnet: status programmable by user (can be used via CODESYS library): LED (A, B) green: Status of system power supply: field supply
input and output internal process image max:
1000 Worte/1000 Worte
input and output modbus process image max:
e!RUNTIME: 32000 Worte/32000 Worte
input current typ at nominal load 24 v:
550 mA
internal memory flash:
4096 MB
isolation:
500 V system/field
main memory ram:
512 MB
memory card slot:
Push-push mechanism: Cover lid (sealable)
memory card type:
SD and SDHC up to 32 GB (all guaranteed properties only valid with WAGO 758-879/000-001 Memory Card)
mounting position:
Any
mounting type:
DIN-35 rail
non volatile hardware memory:
128 kB
non volatile software memory:
128 kB
number of modules per node max:
250
number of modules without a bus extension max:
64
number of outgoing power jumper contacts:
3
operating altitude:
Without temperature derating: 0 2000 m: with temperature derating: 2000 5000 m (0.5 K/100 m): 5000 m (max.)
operating system:
Real-time Linux (with RT-Preempt patch)
packaging type:
Box
permissible h2s contaminant concentration at a relative humidity 75:
10 ppm
permissible so2 contaminant concentration at a relative humidity 75:
25 ppm
pollution degree 5:
2 per IEC 61131-2
program memory:
32 MB
programming environment:
e!COCKPIT (based on CODESYS V3)
programming languages per iec 61131 3:
Instruction List (IL) || Ladder Diagram (LD) || Function Block Diagram (FBD), Continuous Function Chart (CFC) || Structured Text (ST) || Sequential Function Chart (SFC)
protection type:
IP20
relative humidity without condensation:
0.95
shock resistance:
15g per IEC 60068-2-27
solid conductor:
0.08 2.5 mm / 28 14 AWG
strip length:
8 9 mm / 0.31 0.35 inch
supply voltage field:
24 VDC (-25 +30 %): via power jumper contacts
supply voltage system:
24 VDC (-25 +30 %): via pluggable connector (CAGE CLAMP connection)
surrounding air temperature operation:
0 55 C
surrounding air temperature storage:
-25 85 C
total current system supply:
1700 mA
transmission medium communication fieldbus:
ETHERNET: Twisted Pair S-UTP: 100 : Cat. 5: 100 m maximum cable length
vibration resistance:
4g per IEC 60068-2-6
visualization:
Web Visu
weight:
214.928 g
width: