Controller PFC200; 2nd Generation; 2 x ETHERNET M12, RS-232/-485; Extreme.
The WAGO PFC200 XTR series PLC CPU unit, specifically the PFC200 G2 2ETH M12 RS, features an ARM Cortex-A8 1GHz processor with 512MB RAM and 4GB internal flash memory. It supports up to 64 connections per node and offers extensive communication capabilities including Modbus RTU, Modbus TCP, Ethernet/IP, EtherCAT, RS-232, and RS-485. The unit operates on a 24Vdc supply voltage, includes a 9-pin D-sub connector and a CAGE CLAMP 2-pin system, and is designed for DIN-35 rail mounting with a width of 112mm. It also has an SD and SDHC card slot supporting up to 32GB, is rated IP20, and can function in ambient temperatures ranging from -40°C to +70°C.
- baud rate:
- ETHERNET: 10/100 Mbit/s
- baud rate communication fieldbus 1:
- 10/100 Mbit/s
- color:
- Dark gray
- communication:
- Modbus (TCP, UDP) || ETHERNET || EtherNet/IPTM Adapter (slave), library for e!RUNTIME || Modbus RTU || RS-232 serial interface || RS-485 serial interface || MQTT || EtherCAT Master, requires an additional license || BACnet/IP, requires an addition
- configuration options:
- e!COCKPIT || WAGO-I/O-CHECK || Web-Based Management || e!RUNTIME Library || CODESYS Library
- conformity marking:
- CE
- connection technology communication fieldbus:
- Modbus TCP/UDP: 2 x M12 socket: 4-pole: D-coded: Modbus RTU: 1 x D-sub 9 socket: RS-232 serial interface: 1 x D-sub 9 socket: RS-485 serial interface: 1 x D-sub 9 socket
- connection technology device configuration:
- 1 x Male connector: 4-pole
- connection technology field supply:
- 4 x CAGE CLAMP
- connection technology system supply:
- 2 x CAGE CLAMP
- connection type 1:
- System/field supply
- country of origin sales organisation germany:
- DE
- cpu:
- Cortex A8: 1 GHz
- current carrying capacity power jumper contacts:
- 0.416666666666667
- data memory:
- CODESYS V2: 64 MB: e!RUNTIME: 128 MB
- depth:
- 71.9 mm / 2.831 inch
- depth from upper edge of din rail:
- 64.7 mm / 2.547 inch
- derating:
- Derating (supply voltage): Surrounding air temperatures under laboratory conditions: (-25 +30 %): for -40 +55 C: 24 V (-25 +20 %): for +55 +70 C: 24 V (-25 +10 %): Lower limit in all temperature ranges: 27.5 % (
- emc emission of interference:
- Per EN 61000-6-3, -4, EN 61131-2, EN 60255-26, marine applications, EN 60870-2-1, EN 61850-3, EN 50121-3-2, EN 50121-4, -5
- emc immunity to interference:
- Per EN 61000-6-1, -2: EN 61131-2: marine applications: EN 50121-3-2: EN 50121-4, -5: EN 60255-26: EN 60870-2-1: EN 61850-3: IEC 61000-6-5: IEEE 1613: VDEW: 1994
- ethernet protocols:
- DHCP || DNS || NTP || FTP || FTPS || SNMP || HTTP || HTTPS || SSH
- exposure to pollutants:
- Per IEC 60068-2-42 and IEC 60068-2-43
- fine stranded conductor:
- 0.25 2.5 mm / 24 14 AWG
- fire load:
- 0.378 MJ
- height:
- 100 mm / 3.937 inch
- housing material:
- Polycarbonate: polyamide 6.6
- indicators:
- LED (SYS, RUN, I/O, U1 U7) red/green/orange: Status of system, program, local data bus, status programmable by user (can be used via CODESYS library): LED (A, C) green: Status of system power supply, field supply
- input and output internal process image max:
- 1000 Worte/1000 Worte
- input and output modbus process image max:
- CODESYS V2: 1000 Worte/1000 Worte: e!RUNTIME: 32000 Worte/32000 Worte
- input current typ at nominal load 24 v:
- 550 mA
- internal memory flash:
- 4096 MB
- main memory ram:
- 512 MB
- memory card slot:
- Push-push mechanism: Cover lid (sealable)
- memory card type:
- SD and SDHC up to 32 GB (all guaranteed properties only valid with WAGO Memory Card)
- mounting position:
- Horizontal (standing/lying): vertical
- mounting type:
- DIN-35 rail
- non volatile hardware memory:
- 128 kB
- non volatile software memory:
- 128 kB || 128 kB
- number of modules per node max:
- 64
- number of outgoing power jumper contacts:
- 2
- operating altitude:
- Without temperature derating: 0 2000 m: with temperature derating: 2000 5000 m (0.5 K/100 m): 5000 m (max.)
- operating system:
- Real-time Linux (with RT-Preempt patch)
- packaging type:
- Box
- pollution degree 5:
- 2 per IEC 61131-2
- program memory:
- CODESYS V2: 16 MB: e!RUNTIME: 32 MB
- programming environment:
- e!COCKPIT (based on CODESYS V3) || WAGO-I/O-PRO V2.3 (based on CODESYS V2.3)
- programming languages per iec 61131 3:
- Instruction List (IL) || Ladder Diagram (LD) || Function Block Diagram (FBD), Continuous Function Chart (CFC) || Structured Text (ST) || Sequential Function Chart (SFC)
- protection type:
- IP20
- rated surge voltage:
- 1 kV
- relative humidity with condensation:
- Short-term condensation per Class 3K7/IEC EN 60721-3-3 and E-DIN 40046-721-3 (except for wind-driven precipitation, water and ice formation)
- relative humidity without condensation:
- 0.95
- shock resistance:
- Per IEC 60068-2-27 (15g/11 ms/half-sine/1,000 shocks: 25g/6 ms/1,000 shocks), EN 50155, EN 61373
- solid conductor:
- 0.25 2.5 mm / 24 14 AWG
- strip length:
- 8 9 mm / 0.31 0.35 inch
- supply voltage field:
- 24 VDC: Power supply via pluggable connector (CAGE CLAMP connection): Transmission via power jumper contacts: Derating must be observed!
- supply voltage system:
- 24 VDC: via pluggable connector (CAGE CLAMP connection): Derating must be observed!
- surrounding air temperature operation:
- -40 70 C
- surrounding air temperature storage:
- -40 85 C
- total current system supply:
- 1700 mA
- transmission medium communication fieldbus:
- ETHERNET: Twisted pair S-UTP: 100 : Cat. 5: M12 D-coded: 100 m maximum cable length
- vibration resistance:
- Per IEC 60068-2-6 (acceleration: 5g), EN 60870-2-2, IEC 60721-3-1, -3, EN 50155: EN 61373
- visualization:
- Web Visu
- weight:
- 259.200 g
- width:
- 112 mm / 4.409 inch