dielectric strength control load circuit ac 1 min:
3.75 kVrms
fire load:
0.000 MJ
height from the surface:
15 mm / 0.591 inch
input voltage range high level:
DC 35 ª 72 V
input voltage range low level:
DC 0 ª 10 V
leakage current at rated voltage:
«± 1 A
limiting continuous current:
0.1 A
mounting type:
Pluggable module
nominal input current at un:
2.8 mA
nominal input voltage un:
DC 60 V
nominal output voltage:
DC 24 V
note:
Optocouplers and solid state relays are designed for use in signal processing networks, which are not supplied by the low-voltage power supply networks.