M12 Junction Boxes

Passive M12 Junction Boxes for Sensor and Actuator Wiring

A passive M12 junction box gathers several sensors and actuators at the machine and sends them back to the controller over one home-run cable, so you run one cable to the panel instead of one per device. Automation Distribution carries 4, 6, and 8-port M12 junction boxes from Turck, WAGO, and Murrelektronik, with integral cable, M23, and 1-1/8" minifast home runs, and with or without LED indicators.

Choose the number of ports, the pin count of your sensor cordsets, and how the home run connects to the panel. The selection guide below the product list walks through each choice.

Choose by Home-Run Connection

Integral Cable The home-run cable is molded into the box. WAGO 757 boxes come with 5, 10, or 25 m of cable. Fewest connections, but the length is fixed.
M23 Connector A multi-pin M23 connector on the box takes a separate home-run cordset, so the box can be swapped without pulling cable.
1-1/8" Minifast Connector Turck RSF 120 boxes use a 12-pin minifast home-run connector, available in top-exit versions for tight mounting.
Terminal Chamber and Modular Caps Turck TB boxes with a terminal chamber for your own supply cable, and Murrelektronik caps that fit their M12 distribution box bases.

Jump to: Selection guide  |  Reading a Turck part number  |  FAQ  |  All M12 connectors

How to Choose an M12 Junction Box

Decision Options How to choose
Number of ports4, 6, 8Count the sensors and actuators in that area of the machine and leave a spare port or two for future devices.
Pins per port4-pole, 5-poleMatch the pin count of the sensor cordsets that will plug into the box.
Signals per port1 or 2One signal per port for standard sensors. Two per port when a device has two outputs, such as a dual-channel sensor or a valve with two coils.
LED indicatorsNone, PNP, NPNLEDs show power and the state of each signal at the box. Choose PNP or NPN to match the sensor outputs.
Home-run connectionIntegral cable, M23, 1-1/8" minifast, terminal chamberIntegral cable for the fewest connections. A connector when the box needs to be replaced without pulling cable.
Home-run length5, 10, 25 m on WAGO integral-cable boxesMeasure the routed path from the box to the panel. For other lengths, choose a connector version and a separate home-run cordset.

Check the current rating as well. Turck's 4-port eurofast boxes with a minifast home run, for example, are rated 2 A per signal and 7 A total.

Reading a Turck Junction Box Part Number

Turck multibox part numbers spell out the configuration. Using 4MB12Z-4P2-RSF120 as an example:

Part Meaning
4MBNumber of ports (4MB = 4 ports, 8MB = 8 ports)
12ZPort connector: 12 = eurofast M12, 12Z = eurofast low profile, M12 = miniature eurofast
4Pins per port (4 or 5)
PLED type: P = PNP LEDs, N = NPN LEDs, blank = no LEDs
2LEDs: 1 = power LED only, 2 = one signal LED per port plus power, 3 = two signal LEDs per port plus power
RSF120Home run: RSF 120 / RSM 120 = 12-pin 1-1/8" minifast connector (mates with RKM 126 cordsets), CS12 / CS19 = M23 multifast connector, a number alone = integral cable length in meters

M12 Junction Box FAQ

What is a passive M12 junction box?

A passive M12 junction box is a sealed housing with several M12 ports that wires each sensor or actuator signal back to a single home-run cable or connector. It has no network electronics, so the signals still land on I/O in the control panel. It replaces many individual cable runs with one, which cuts cable tray fill and wiring time.

What is the difference between a passive junction box and an I/O block?

A passive junction box only consolidates wiring; each signal still needs its own conductor and its own input or output point in the panel. An active I/O block has network electronics, so it sends all signals over one Ethernet or fieldbus connection. Passive boxes are simpler and cost less, while I/O blocks reduce panel I/O and support diagnostics.

Do I need PNP or NPN LEDs?

Match the LED type to the switching type of your sensors. PNP (sourcing) sensors need a box with PNP LEDs and NPN (sinking) sensors need NPN LEDs, or the signal LEDs will not light correctly. Boxes without LEDs work with either, but you lose the visual status at the machine.

Should I choose integral cable or a home-run connector?

Integral cable has the fewest connection points and is ready to wire into the panel, but the length is fixed and replacing the box means pulling the cable. A connector version lets you replace the box or the home-run cable separately, and choose any home-run length. Most maintenance teams prefer the connector version on machines that see frequent changeovers.

What should I do with unused ports?

Cover every unused port with the manufacturer's M12 sealing cap. An open port does not carry the protection rating of a mated connection, so dust and washdown can enter the box. Caps are listed in the M12 Adapters & Accessories category.

Planning a junction box layout?

Send us your sensor count, sensor types, and the distance to the panel, and the Automation Distribution team will help you size the box, home run, and cordsets. Contact Automation Distribution or call 1-888-600-3080.