PULS SP960.481-S PLANET DIN Rail Power Supply, 48VDC 20A 960W, 1-Phase 100-240VAC Input, Screw Terminals

PULS
SKU:
SP960.481-S
$1,035.00
Condition:
New
Current Stock:

The PULS SP960.481-S is a 48 VDC, 20 A, 960 W single-phase DIN rail power supply from the PULS PLANET SP series, the top-of-the-line industrial range from PULS. In a housing only 96 mm wide, it delivers 95.1% efficiency at 120 VAC (96.5% at 230 VAC), 1152 W of continuous BonusPower up to +45°C, and 1440 W peaks for up to 5 seconds at temperatures up to +70°C. That headroom lets you size for the steady-state load instead of the start-up peaks from 48 V drives, motors, and heavily capacitive loads.

Key Features

  • Dynamic BonusPower Management: delivers 110% of rated power for 30 s or up to 150% for 5 s, with 120% available continuously up to +45°C
  • Compact 96 mm width: 960 W of 48 V power with a small DIN rail footprint
  • High efficiency, low idle loss: only 2.6 W power loss at no load and 49.5 W at full load on 120 VAC
  • Fuse breaking current: typically 40 A for up to 12 ms to trip fuses and breakers on faulted output branches while the output stays above 40 V
  • HiccupPLUS overload protection: protects both the supply and downstream equipment, with automatic restart once the overload clears
  • Back-feed resistant: tolerates up to 60 V / 1 J fed back from regenerating motors or other loads, whether the unit is on or off
  • DC OK relay contact and LED: remote diagnostics through an isolated relay contact plus a green/red front-panel status LED
  • Parallel Use link: front-panel jumper switches the unit into load-sharing mode for paralleled or redundant systems
  • Hazardous location rated: Class I Division 2 Groups A, B, C, D, ATEX and IECEx Zone 2 (T4)
  • 3-year PULS warranty

Specifications

ParameterSP960.481-S
Output voltage 48 VDC nominal, adjustable 48-56 VDC (factory set 48 V)
Output current (120-240 VAC) 20 A up to +60°C, 15 A at +70°C
Output power 960 W continuous
BonusPower continuous 1152 W (24 A at 48 V) up to +45°C
BonusPower short term 1440 W (30 A at 48 V) for 5 s, up to +70°C
Input voltage 100-240 VAC nominal (90-264 VAC), 50-60 Hz, single phase
Input current 8.4 A at 120 VAC, 4.34 A at 230 VAC
Power factor 0.998 at 120 VAC, 0.994 at 230 VAC
Inrush current (typ.) 14 A peak at 120 VAC, 8 A peak at 230 VAC
Efficiency 95.1% at 120 VAC, 96.5% at 230 VAC
Hold-up time 28 ms at 20 A, 56 ms at 10 A (typ.)
Ripple and noise 150 mVpp max (20 Hz to 20 MHz)
Output capacitance 4,480 µF internal
Operating temperature -25°C to +70°C (derate above +60°C)
Altitude Up to 5000 m (derating above 2000 m)
Terminals Screw terminals, input AWG 20-10, output AWG 22-8; push-in signal terminals AWG 26-14
DC OK relay rating 60 VDC 0.3 A, 30 VDC 1 A, 30 VAC 0.5 A (resistive)
Protection IP20, overtemperature, output overvoltage (60 V max), MOV input transient protection, internal input fuse
Housing Aluminum alloy body, zinc-plated steel cover
Dimensions (W x H x D) 96 x 124 x 132 mm (3.78 x 4.88 x 5.20 in), without DIN rail
Weight 3.75 lb (1700 g)
MTBF (SN 29500) 341,714 h at 120 VAC, 20 A, +40°C

How Dynamic BonusPower Works

Instead of a fixed peak rating, the power supply monitors output through a power-time integral. The less extra power a load draws, the longer BonusPower stays available, and the supply recovers within seconds after a peak, so repeated motor starts and actuator cycles are supported without nuisance shutdowns.

BonusPower UsedAvailable up to +45°CAvailable up to +60°C
110% Continuous 30 s
120% Continuous 14 s
130% 16 s 9 s
140% 8 s 7 s
150% 5 s 5 s

Typical Applications

  • 48 V servo and stepper drive systems, where acceleration peaks exceed steady-state draw
  • 48 V conveyor motors, mobile robot charging stations, and material handling equipment
  • Semiconductor process equipment requiring SEMI F47 voltage sag immunity
  • Oil and gas, chemical, and other Class I Div 2 / Zone 2 hazardous locations
  • Paralleled and redundant 48 V systems using the YR40.482 redundancy module

Approvals and Compliance

cULus Listed to UL 61010-2-201 (E-File E198865, US and Canada), CB Scheme to IEC 61010-2-201 and IEC 62368-1, IEC 61558-2-16 (Annex BB), ATEX (EPS 25 ATEX 1 144 U, II 3G Ex ec nC IIC Gc), IECEx (IECEx EPS 25.0040U), Class I Division 2 Groups A, B, C, D, SELV/PELV, SEMI F47, CE, REACH, WEEE, and China RoHS 2. EMC emissions meet Class B per EN 55011 and EN 55032, and the unit complies with FCC Part 15.

Installation Notes

  • Mount on a 35 mm DIN rail (EN 60715) with input terminals on the bottom. Other orientations require output derating.
  • Keep 40 mm clearance above and below and 5 mm on each side (15 mm next to a heat source or another power supply in parallel).
  • Approved for branch circuits up to 30 A (UL) without additional protection. If an external breaker is used, choose 16 A minimum, B or C characteristic.
  • Protective earth connection is required (Class I equipment). Do not operate with DC input.
  • In hazardous locations, use only the standard vertical orientation and limit output to 22 A maximum.

Complementary PULS Products

  • ZM2.WALL: wall / panel mount bracket
  • UF20.481: 48 V, 20 A buffer module for ride-through during short power interruptions
  • YR40.482: redundancy module for 1+1 and N+1 redundant systems

Need help sizing your 48 V power system?

Automation Distribution is an authorized PULS distributor. Our team can help you select the right PULS power supply and accessories for your panel, parallel, or redundant power application.

Contact Automation Distribution
Series:
PULS PLANET SP
Output Voltage:
48 VDC (adjustable 48-56 VDC)
Output Current:
20 A continuous
Output Power:
960 W
BonusPower:
1152 W continuous to +45°C, 1440 W for 5 s
Input Voltage:
100-240 VAC (90-264 VAC range)
Input Phase:
1-Phase
Efficiency:
95.1% at 120 VAC, 96.5% at 230 VAC
Hold-Up Time:
28 ms at full load
Operating Temperature:
-25°C to +70°C
Dimensions (W x H x D):
96 x 124 x 132 mm
Connection:
Screw terminals (push-in signal terminals)
Signaling:
DC OK relay contact and LED
Approvals:
cULus Listed (UL 61010-2-201), ATEX, IECEx, Class I Div 2, SEMI F47
Warranty:
3 years