Schneider Electric 8536SHO2V06H30 NEMA Motor Starter, Type S, nonreversing, Size 6, 540A, 400 HP at 460 VAC, up to 100 kA SCCR, 3 phase, 3 pole, Motor Logic, 480 VAC coil, open
Schneider Electric
$21,971.00
Type S NEMA motor starters are used for full voltage starting and stopping of AC squirrel cage motors. Type S motor starters have ratings up to 810 amperes. This 3 pole NEMA Size 6 non-reversing starter has a 540 ampere rating. This NEMA Size 6 motor starter has 3 phase ratings of 150 HP at 200 VAC, 200 HP at 230 VAC and 400 HP at 460 and 575 VAC. This non-reversing NEMA motor starter has a Motor Logic overload relay with a 180A to 540A range to sense over current conditions. This NEMA starter has a 100 kA maximum SCCR per UL508A when protected by an appropriate fuse. Type S motor starters are available with replaceable coils in a wide variety of voltages. This starter has a 440/480 VAC 50/60 Hz operating coil wired for common control. This NEMA starter is an open device without an enclosure. This starter is 28.06 inches tall, 12.34 inches wide and 9.00 inches deep. A wide variety of accessories are available for Type S starters. Type S non-reversing NEMA motor starters are UL listed and CSA certified. This NEMA starter has a 65 kA maximum SCCR (Short Circuit Current Rating) per UL508A when protected by an appropriate circuit breaker.
- [Ue] Rated Operational Voltage:
- 600 V AC
- Product Certifications:
- UL Listed || CSA || NEMA
- Warranty:
- 18 months
- Electrical Connection:
- screw clamp terminals
- Phase:
- 3 phase
- Control Circuit:
- control circuit transformer
- Country of Origin:
- Mexico
- Eu Rohs Directive:
- Not compliant
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Range Of Product:
- S
- Provided Equipment:
- 2 fuses (primary), 2 fuses (secondary)
- Control Type:
- no control units
- Depth:
- 253 mm
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
- Thermal Overload Type:
- solid state Motor Logic class 10/20
- Product Or Component Type:
- motor starter
- Poles Description:
- 3P
- [Uc] Control Circuit Voltage:
- 440 V AC 50 Hz || 480 V AC 60 Hz
- Line Rated Current:
- 540 A
- Rated Power In Hp:
- 150 HP 200 V AC || 200 HP 230 V AC || 400 HP 460 V AC || 400 HP 575 V AC
- Motor Starter Type:
- non reversing
- Nema Degree Of Protection:
- not rated (open device)
- Local Signaling:
- without pilot light
- Nema Size:
- 6
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Auxiliary Contact Composition:
- without