Product Certifications:
CE IEC 61010-1 safety) || CE EN 61557-12 power monitor) || CE EN/IEC 61326-1 EMC) || UKCA BS EN 61010-1 safety) || UKCA BS EN 61557-12 power monitor) || UKCA BS EN 61326-1 EMC) || cULus UL 61010-1 safety) || cULus EN 61010-1 safety) || KZ || RCM
Number Of Inputs:
1 digital 0...5 V/11...40 V 24 V DC
Technology Type:
electronic
Measurement Current:
50-5000 A
Color:
White
9 Mm Pitches:
10
Device Short Name:
iEM3555
Connections - Terminals:
current circuit screw terminals 6-6 mm² || voltage circuit screw terminals 2.5-2.5 mm² || input/output circuit screw terminals 1.5-1.5 mm² || communication screw terminals 2.5-2.5 mm²
Sustainable Offer Status:
Green Premium product
Relative Humidity:
5-95 % 36-36°C
Rohs Exemption Information:
Yes
Display Type:
LCD display
Maximum Value Measured:
99999999.9 kWh || 99999999 MWh
Type Of Measurement:
active and reactive energy || active and reactive power || current || voltage
Ambient Air Temperature For Operation:
-25-70°C - IEC
California Proposition 65:
WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
Output Voltage:
5...40 V DC@50 mA
Number Of Outputs:
1 digital (static)
Local Signaling:
Green indicator light power ON || Yellow flashing LED accuracy checking || alarm overload || Yellow indicator light communications are active on the Modbus port (Modbus)
Poles Description:
3P || 3P + N || 1P + N
Tightening Torque:
input/output circuit 0.5-0.5 N.m Philips || voltage circuit 0.5-0.5 N.m Philips || current circuit 0.8-0.8 N.m pozidriv || communication 0.5-0.5 N.m Philips
Pollution Degree:
2
Sampling Rate:
32 samples/cycle
Range:
Acti9
Device Application:
multi-tariff || partial meter || sub billing
China Rohs Regulation:
X
Communication Port Support:
screw terminal block RS485
Ip Degree Of Protection:
IP40 front panel: conforming to IEC 60529 || IP20 body: conforming to IEC 60529
Product Name:
Acti9 iEM3000
Mercury Free:
Yes
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Information Displayed:
tariff 4)
Rated Voltage:
100-277 V +/- 20 % || 173-480 V +/- 20 %
Standards:
BS EN 61326-1 || IEC 61326-1 || EN 61326-1 || BS EN 61010-1:2010 || EN 61010-1:2010 || IEC 61010-1:2010 || UL 61010-1:2010 || BS EN 61010-2-30 || IEC 61010-2-30 || EN 61010-2-30 || UL 61010-2-30 || ANSI C12.20
Metering Type:
active, reactive, apparent energy (signed, four quadrant)
Analogue Input Type:
Rogowski coil 50...5000 A
Environmental Disclosure:
ENVPEP111276EN
Ik Degree Of Protection:
IK08
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Network Frequency:
50 Hz || 60 Hz
Mounting Support:
DIN rail
Ambient Air Temperature For Storage:
-40-85°C
Accuracy Class:
class 0.5S active energy IEC 62053-22 || class 0.5S active energy ANSI C12.20
Communication Port Protocol:
Modbus RTU 9.6, 19.2 and 38.4 kbauds even/odd or none
Wire Stripping Length:
input/output circuit: 6 mm || voltage circuit: 8 mm || current circuit: 8 mm || communication: 7 mm
Depth:
69 mm
$695.10

Description

The Acti9 iEM3000 series energy meters offer an attractive range of three-phase DIN rail-mounted energy meters with an LCD display. Additional local signaling includes green LED power-on indicator, flashing yellow LED for accuracy checking, an overload alarm and communication indicators. This meter can be used in sub-billing applications and supports 4 tariff schedules. The meter provides the following accuracy classes: Active Energy: class 0.5S per IEC 62053-21, and per ANSI C12.20. The meter will measure Active and Reactive Power, Active and Reactive Energy, Voltage and Current. With four quadrant Energy measurement. Designed for 50Hz or 60Hz networks, supply voltage can range from 100 to 277VAC or 173 to 480VAC. The rated current goes through a Rogowski coil to be measured in this meter and will support Single Phase and Neutral, Three Phase and Three Phase and Neutral configurations. Communication protocol is Modbus with screw terminal support. There is one programmable digital input and one programmable digital output that can be used as a pulsed output. Certifications include EAC, CE and UL. Product dimensions are as follows: width 3.54 in (90 mm), depth 2.72in (69 mm), height 3.42 in (87 mm). Compatible with power management software to take advantage of the IoT digital power installation.