Schneider Electric

Schneider Electric ATV650U15N4U Variable speed drive, Altivar Process ATV600, ATV650, 1.5 kW, 400...480 V, IP55

(No reviews yet) Write a Review
SKU:
ATV650U15N4U
MPN:
ATV650U15N4U
Condition:
New
Degree Of Protection:
UL type 12 UL 508C
California Proposition 65:
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Motor Slip Compensation:
automatic whatever the load || not available in permanent magnet motor law || can be suppressed
Transmission Rate:
10, 100 Mbits || 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps
Type Of Polarization:
no impedance
Standards:
EN/IEC 61800-3 environment 1 category C2 || EN/IEC 61800-3 environment 2 category C3 || EN/IEC 61800-5-1 || IEC 61000-3-12 || IEC 60721-3 || IEC 61508 || IEC 13849-1 || UL 508C
Physical Interface:
Ethernet || 2-wire RS 485
Phase:
3 phase
Electrical Connection:
line side screw terminal 4...6 mm² || motor screw terminal 4...6 mm² || control removable screw terminals 0.5...1.5 mm² AWG 20...AWG 16
Product Specific Application:
process and utilities
Relay Output Type:
configurable relay logic R2 sequence relay NO 100000 cycles || configurable relay logic R3 sequence relay NO 100000 cycles || configurable relay logic R1 fault relay NO/NC 100000 cycles
Asynchronous Motor Control Profile:
optimized torque mode || variable torque standard || constant torque standard
Local Signaling:
for embedded communication status 3 LEDs (dual colour) || for communication module status 4 LEDs (dual colour) || for presence of voltage 1 LED (red) || for local diagnostic 3 LEDs
Discrete Input Logic:
positive logic (source) DI1...DI8), < 5 V, > 11 V || negative logic (sink) DI1...DI8), > 16 V, < 10 V
Product Certifications:
UL || CSA || TÃœV || DNV-GL || Bureau Veritas || ABS || ATEX INERIS
Pollution Degree:
3
[Us] Rated Supply Voltage:
380...480 V
Linearity Error:
AO1, AO2 +/- 0.2 % analog output || AI1, AI2, AI3 +/- 0.15 % of maximum value analog input
Ip Degree Of Protection:
IP55IEC 60529 || IP55IEC 61800-5-1
Line Current:
2.6 A 480 V normal duty) || 1.7 A 380 V heavy duty) || 1.5 A 480 V heavy duty) || 3 A 380 V normal duty)
Operating Altitude:
1000...4800 m with current derating 1 % per 100 m || <= 3280.84 ft (1000 m) without derating
Frequency Resolution:
analog input 0.012/50 Hz || display unit 0.1 Hz
Electromagnetic Compatibility:
radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3 || electrical fast transient/burst immunity test level 4 IEC 61000-4-4 || 1.2/50µs - 8/20µs surge immunity test level 3 IEC 61000-4-5 || conducted radio-frequency immu
Synchronous Motor Control Profile:
synchronous reluctance motor || permanent magnet motor
Ambient Air Temperature For Operation:
40-50°C with derating factor) || -15-40°C without derating)
Analogue Output Type:
software-configurable voltage AQ1, AQ2 0...10 V DC 470 Ohm 10 bits || software-configurable current AQ1, AQ2 0...20 mA 10 bits || software-configurable current DQ-, DQ+ 30 V DC || software-configurable current DQ-, DQ+ 100 mA
Depth:
272 mm
Circularity Profile:
ENVEOLI1508009EN
Output Voltage:
<= power supply voltage
Enclosure Mounting:
wall mounted
Maximum Thdi:
<48 % full load IEC 61000-3-12
Continuous Output Current:
2.2 A 4 kHz heavy duty || 4 A 4 kHz normal duty
Relay Output Number:
3
Data Format:
8 bits, configurable odd, even or no parity
Communication Port Protocol:
Modbus TCP || Ethernet
Emc Filter:
integrated 50 m EN/IEC 61800-3 category C2 || integrated 150 m EN/IEC 61800-3 category C3
Accuracy:
+/- 1 % AO1, AO2 for a temperature variation 60°C analog output || +/- 0.6 % AI1, AI2, AI3 for a temperature variation 60°C analog input
Method Of Access:
slave Modbus TCP
Connector Type:
RJ45 on the remote graphic terminal)Modbus serial || RJ45 on the remote graphic terminal)Ethernet/Modbus TCP
Discrete Input Number:
8
Safety Function:
STO (safe torque off) SIL 3
Width:
264 mm
Range Of Product:
Altivar Process ATV600
Noise Level:
52 dB 86/188/EEC
China Rohs Regulation:
X
Country of Origin:
China
Protection Type:
safe torque off motor || motor phase break motor || thermal protection drive || safe torque off drive || overheating drive || overcurrent between output phases and earth drive || overload of output voltage drive || short-circuit protection drive || m
Height:
678 mm
Shock Resistance:
15 gn 11 ms IEC 60068-2-27
Upgradeability:
Upgraded components available
$2,658.24