Schneider Electric ATV930D37N4ZU variable speed drive, Altivar Process ATV900, ATV930, 50hp, 380 to 480V, cabinet Integration, IP20, for US
Schneider Electric
$5,464.32
variable speed drive, Altivar Process ATV900, ATV930, 50hp, 380 to 480V, cabinet Integration, IP20, for US
- Discrete Input Number:
- 10
- Brake Chopper Integrated:
- TRUE
- Environmental Disclosure:
- ENVPEP2007012EN
- Asynchronous Motor Control Profile:
- variable torque standard || optimized torque mode || constant torque standard
- Apparent Power:
- 47.6 kVA 480 V normal duty) || 40.2 kVA 480 V heavy duty)
- Maximum Output Voltage:
- 480.0 V
- Net Weight:
- 26 kg
- Supply:
- external supply for digital inputs 24 V DC 19-30 V), <1.25 mA overload and short-circuit protection || internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 mA overload and short-circuit protection || internal supply for d
- Noise Level:
- 71.5 dB 86/188/EEC
- Overvoltage Category:
- III
- With Safety Function Safe Torque Off (Sto):
- TRUE
- Linearity Error:
- AI1, AI2, AI3 +/- 0.15 % of maximum value analog input || AQ1, AQ2 +/- 0.2 % analog output
- Isolation:
- between power and control terminals
- Relay Output Number:
- 3
- Type Of Polarization:
- no impedance
- Line Current:
- 66.2 A 380 V normal duty) || 54.8 A 380 V heavy duty) || 57.3 A 480 V normal duty) || 48.3 A 480 V heavy duty)
- Electromagnetic Compatibility:
- electrostatic discharge immunity test level 3 IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3 || electrical fast transient/burst immunity test level 4 IEC 61000-4-4 || 1.2/50µs - 8/20µs surge immuni
- Electrical Connection:
- control screw terminal 0.5...1.5 mm² AWG 20...AWG 16 || DC bus screw terminal 25...50 mm² AWG 4...AWG 1 || line side screw terminal 35...50 mm² AWG 3...AWG 1 || motor screw terminal 35...50 mm² AWG 3...AWG 1
- With Safety Function Safe Programmable Logic:
- FALSE
- Ip Degree Of Protection:
- IP21
- Local Signaling:
- local diagnostic 3 LED mono/dual colour) || embedded communication status 5 LED dual colour) || communication module status 2 LED dual colour) || presence of voltage 1 LED red)
- Relative Symmetric Network Frequency Tolerance:
- 0.05
- [Us] Rated Supply Voltage:
- 380...480 V - 15...10 %
- Data Format:
- 8 bits, configurable odd, even or no parity Modbus serial
- Relative Humidity:
- 5-95 % without condensation IEC 60068-2-3
- Analogue Input Type:
- AI1, AI2, AI3 software-configurable voltage 0...10 V DC 30 kOhm 12 bits || AI1, AI2, AI3 software-configurable current 0...20 mA/4...20 mA 250 Ohm 12 bits
- Communication Port Protocol:
- Modbus TCP || Modbus serial || EtherNet/IP
- Marking:
- CE
- Height:
- 597 mm
- Assembly Style:
- with heat sink
- Relay Output Type:
- configurable relay logic R1 fault relay NO/NC 100000 cycles || configurable relay logic R2 sequence relay NO 1000000 cycles || configurable relay logic R3 sequence relay NO 1000000 cycles
- Volume Of Cooling Air:
- 240 m3/h
- Standards:
- UL 508C || IEC 61800-3 || IEC 61800-5-1 || IEC 61000-3-12 || IEC 60721-3 || IEC 61508 || IEC 13849-1
- Nominal Switching Frequency:
- 4 kHz
- Ambient Air Temperature For Storage:
- -40-70°C
- Maximum Acceleration Under Vibrational Stress (During Operation):
- 10 m/s² at 13...200 Hz
- Maximum Output Frequency:
- 599 Hz
- Environmental Characteristic:
- chemical pollution resistance class 3C3 IEC 60721-3-3 || dust pollution resistance class 3S3 IEC 60721-3-3
- Analogue Input Number:
- 3
- Vibration Resistance:
- 1.5 mm peak to peak 2-13 Hz)IEC 60068-2-6 || 1 gn 13-200 Hz)IEC 60068-2-6
- Mounting Mode:
- cabinet mount
- 4 Quadrant Operation Possible:
- TRUE
- Prospective Line Isc:
- 50 kA
- Transmission Rate:
- 10/100 Mbit/s Ethernet IP/Modbus TCP || 4.8, 9.6, 19.2, 38.4 kbit/s Modbus serial
- Range Of Product:
- Altivar Process ATV900
- Refresh Time:
- relay output R1, R2, R3)5 ms +/- 0.5 ms)
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
- Number Of Addresses:
- 1-247
- Method Of Access:
- slave Modbus TCP
- Maximum Thdi:
- <48 % from 80...100 % of load IEC 61000-3-12