Schneider Electric ATV930U07N4ZU variable speed drive, Altivar Process ATV900, ATV930, 1hp, 380 to 480V, cabinet Integration, IP20, for US
Schneider Electric
$1,196.16
variable speed drive, Altivar Process ATV900, ATV930, 1hp, 380 to 480V, cabinet Integration, IP20, for US
- Operating Position:
- vertical +/- 10 degree
- Base Load Current At Low Overload:
- 2.2 A
- Physical Interface:
- Ethernet || 2-wire RS 485
- Emc Filter:
- integrated || with EMC plate option
- Maximum Output Frequency:
- 599 Hz
- Switching Frequency:
- 2...16 kHz adjustable || 4...16 kHz with derating factor
- With Safety Function Safe Programmable Logic:
- FALSE
- Rohs Exemption Information:
- Yes
- Continuous Output Current:
- 2.2 A 4 kHz normal duty || 1.5 A 4 kHz heavy duty
- With Safety Function Safe Position (Sp):
- FALSE
- Upgradeability:
- Upgraded components available
- Range Of Product:
- Altivar Process ATV900
- Device Application:
- Industrial Application
- Product Certifications:
- CSA || UL || TÃV
- Environmental Class (During Operation):
- class 3C3 according to IEC 60721-3-3 || class 3S3 according to IEC 60721-3-3
- Braking To Standstill:
- by DC injection
- Nominal Switching Frequency:
- 4 kHz
- Maximum Acceleration Under Vibrational Stress (During Operation):
- 10 m/s² at 13...200 Hz
- Pollution Degree:
- 2
- Relative Humidity:
- 5-95 % without condensation IEC 60068-2-3
- Maximum Thdi:
- <48 % full load IEC 61000-3-12
- Transmission Frame:
- RTU
- With Sft Fct Safe Stop 2 (Ss2):
- FALSE
- Number Of Addresses:
- 1-247
- Ambient Air Temperature For Operation:
- -15-50°C without derating) || 50-60°C with derating factor)
- Relay Output Type:
- configurable relay logic R1 fault relay NO/NC 100000 cycles || configurable relay logic R2 sequence relay NO 1000000 cycles || configurable relay logic R3 sequence relay NO 1000000 cycles
- Acceleration And Deceleration Ramps:
- linear adjustable separately from 0.01...9999 s
- Analogue Input Number:
- 3
- With Safety Function Safe Torque Off (Sto):
- TRUE
- Maximum Deflection Under Vibratory Load (During Operation):
- 1.5 mm at 2...13 Hz
- Permitted Relative Humidity (During Operation):
- class 3K5 according to EN 60721-3
- Communication Port Protocol:
- Modbus TCP || EtherNet/IP || Modbus serial
- Accuracy:
- +/- 0.6 % AI1, AI2, AI3 for a temperature variation 60°C analog input || +/- 1 % AQ1, AQ2 for a temperature variation 60°C analog output
- Motor Slip Compensation:
- not available in permanent magnet motor law || can be suppressed || automatic whatever the load || adjustable
- Operating Altitude:
- <= 3280.84 ft (1000 m) without derating || 1000...4800 m with current derating 1 % per 100 m
- Quantity Per Set:
- 1
- Depth:
- 196 mm
- Discrete Input Type:
- DI1...DI8 programmable, 24 V DC <= 30 V)3.5 kOhm || DI7, DI8 programmable as pulse input 0-30 kHz, 24 V DC <= 30 V) || STOA, STOB safe torque off, 24 V DC <= 30 V)> 2.2 kOhm
- Input Compatibility:
- DI1...DI8 discrete input level 1 PLC IEC 61131-2 || DI7, DI8 pulse input level 1 PLC IEC 65A-68 || STOA, STOB discrete input level 1 PLC IEC 61131-2
- Refresh Time:
- relay output R1, R2, R3)5 ms +/- 0.5 ms)
- Width:
- 130 mm
- Type Of Polarization:
- no impedance
- Variant:
- standard version || with braking chopper
- Circularity Profile:
- ENVEOLI2007009EN
- With Safety Function Safely Limited Position (Slp):
- FALSE
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Maximum Output Voltage:
- 480.0 V
- Power Dissipation In W:
- natural convection 26 W 380 V 4 kHz || forced convection 21 W 380 V 4 kHz
- Noise Level:
- 54.5 dB 86/188/EEC
- Discrete Output Type:
- logic output DQ+ 0-1 kHz <= 30 V DC 100 mA || programmable as pulse output DQ+ 0-30 kHz <= 30 V DC 20 mA || logic output DQ- 0-1 kHz <= 30 V DC 100 mA