Schneider Electric

Schneider Electric ATV950U15N4U variable speed drive, Altivar Process ATV900, ATV950, 1.5kW, 2hp, 380 to 480V, IP55, UL type 12

(No reviews yet) Write a Review
SKU:
ATV950U15N4U
MPN:
ATV950U15N4U
Condition:
New
Number Of Addresses:
1-247
Accuracy:
+/- 0.6 % AI1, AI2, AI3 for a temperature variation 60°C analog input || +/- 1 % AQ1, AQ2 for a temperature variation 60°C analog output
Marking:
CE
Ambient Air Temperature For Operation:
-15-40°C without derating) || 40-50°C with derating factor)
Analogue Output Type:
software-configurable voltage AQ1, AQ2 0...10 V DC 470 Ohm 10 bits || software-configurable current AQ1, AQ2 0...20 mA 500 Ohm 10 bits
Emc Filter:
integrated || with EMC plate option
Regulation Loop:
adjustable PID regulator
Permitted Relative Humidity (During Operation):
class 3K5 according to EN 60721-3
Discrete Input Number:
10
Relative Humidity:
5-95 % without condensation IEC 60068-2-3
Environmental Class (During Operation):
class 3C3 according to IEC 60721-3-3 || class 3S3 according to IEC 60721-3-3
Analogue Output Number:
2
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Maximum Deflection Under Vibratory Load (During Operation):
1.5 mm at 2...13 Hz
Transmission Rate:
10/100 Mbit/s Ethernet IP/Modbus TCP || 4.8, 9.6, 19.2, 38.4 kbit/s Modbus serial
Product Specific Application:
process for industrial
Product Destination:
asynchronous motors || synchronous motors
Discrete Input Logic:
positive logic (source) DI1...DI8), < 5 V, > 11 V || negative logic (sink) DI1...DI8), > 16 V, < 10 V || positive logic (source) DI7, DI8), < 0.6 V, > 2.5 V || positive logic (source) STOA, STOB), < 5 V, > 11 V
Method Of Access:
slave Modbus TCP
Insulation Resistance:
> 1 MOhm 500 V DC for 1 minute to earth
Maximum Acceleration Under Vibrational Stress (During Operation):
10 m/s² at 13...200 Hz
Maximum Switching Current:
relay output R1 resistive, cos phi = 1 3 A 250 V AC || relay output R1 resistive, cos phi = 1 3 A 30 V DC || relay output R1 inductive, cos phi = 0.4 7 ms 2 A 250 V AC || relay output R1 inductive, cos phi = 0.4 7 ms 2 A 30 V DC || relay output R2, R
Ip Degree Of Protection:
IP55
Ambient Air Temperature For Storage:
-40-70°C
Apparent Power:
2.2 kVA 480 V normal duty) || 1.2 kVA 480 V heavy duty)
With Safety Function Safe Torque Off (Sto):
TRUE
With Safety Function Safely Limited Position (Slp):
FALSE
Discrete Input Logic:
16 preset speeds
Acceleration And Deceleration Ramps:
linear adjustable separately from 0.01...9999 s
Discrete Input Type:
DI1...DI8 programmable, 24 V DC <= 30 V)3.5 kOhm || DI7, DI8 programmable as pulse input 0-30 kHz, 24 V DC <= 30 V) || STOA, STOB safe torque off, 24 V DC <= 30 V)> 2.2 kOhm
Maximum Thdi:
<48 % full load IEC 61000-3-12
Sustainable Offer Status:
Green Premium product
Analogue Input Type:
AI1, AI2, AI3 software-configurable voltage 0...10 V DC 30 kOhm 12 bits || AI1, AI2, AI3 software-configurable current 0...20 mA/4...20 mA 250 Ohm 12 bits
Ambient Air Transport Temperature:
-40-70°C
Asynchronous Motor Control Profile:
optimized torque mode || variable torque standard || constant torque standard
Exchange Mode:
half duplex, full duplex, autonegotiation Ethernet IP/Modbus TCP
Weight:
10.5 kg
Linearity Error:
AI1, AI2, AI3 +/- 0.15 % of maximum value analog input || AQ1, AQ2 +/- 0.2 % analog output
Range Of Product:
Altivar Process ATV900
Noise Level:
52 dB 86/188/EEC
Base Load Current At Low Overload:
4.0 A
Maximum Acceleration Under Shock Impact (During Operation):
150 m/s² at 11 ms
Environmental Disclosure:
ENVPEP1508009EN
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Relay Output Type:
configurable relay logic R1 fault relay NO/NC 100000 cycles || configurable relay logic R2 sequence relay NO 1000000 cycles || configurable relay logic R3 sequence relay NO 1000000 cycles
Continuous Output Current:
4 A 4 kHz normal duty || 2.2 A 4 kHz heavy duty
Analogue Input Number:
3
Standards:
UL 508C || IEC 61800-3 || IEC 61800-5-1 || IEC 61000-3-12 || IEC 60721-3 || IEC 61508 || IEC 13849-1
California Proposition 65:
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Shock Resistance:
15 gn 11 ms IEC 60068-2-27
$2,924.05