Schneider Electric

Schneider Electric BCPMB142S BCPM power monitoring intermediate - 42 solid core 100 A - 26 mm CT spacing

(No reviews yet) Write a Review
SKU:
BCPMB142S
MPN:
BCPMB142S
Condition:
New
Relative Humidity:
0-95 % 0-60°C
Range:
PowerLogic
Device Application:
sub billing
Analogue Input Type:
solid core CT 100 A42 x
Ambient Air Temperature For Storage:
-40-70°C
Variant:
intermediate
Communication Port Support:
RS485
Net Weight:
1.5 kg
Product Name:
PowerLogic BCPM
Provided Equipment:
42 x current transformer || 2 x cables
Communication Port Protocol:
Modbus RTU
Weight:
1.5 kg
Energy Management:
sub billing and cost allocation
California Proposition 65:
WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
Product Certifications:
UL
Operating Altitude:
9842.52 ft (3000 m)
Country of Origin:
United States
China Rohs Regulation:
X
Communication Of Data:
over voltage alarm || high-high current alarm || low current alarm || under voltage alarm || high current alarm || low-low current alarm
Update Time:
1.8 s
[Us] Rated Supply Voltage:
90...277 V AC 50/60 Hz +/- 1 %
Network Frequency:
60 Hz || 50 Hz
Mounting Support:
enclosure || panel
Standards:
UL 508 || IEC 61036 || EN 61010 || ANSI C12.1
Power Quality Analysis:
voltage sag and swell detection
Sampling Rate:
256 samples/cycle
Mounting Mode:
panel-mounted
Measurement Voltage:
90-277 V phase to neutral || 150-480 V phase to phase
Product Or Component Type:
multi-circuit energy meter
Device Short Name:
BCPMB
Type Of Measurement:
voltage || current || frequency || active power || power factor || active energy
Measurement Accuracy:
branch current 2 % 0.25…2 A || branch current 1 % 2…100 A || mains current 3 % 1…100 % || mains current 3 % 2…100 % || voltage 1 % 90…277 V
Connection Pitch:
26 mm
Power Monitoring:
basic instrumentation
Warranty:
18 months
Eu Rohs Directive:
Compliant
$6,260.53

Description

This is an integrated solution for monitoring multi-circuits and mains by using a single meter. The meter is designed for use in new build and is used for critical power operations in data centres and energy management in buildings. It offers class 1 (1 %) power and energy system accuracy (100A solid core current transformers) on all branch channels. The BCPM monitors both the 42 branch circuits and mains values and only the mains incoming power and energy. All to provide information on the complete Power Distribution Unit. Full alarming capabilities ensure that potential issues are dealt with before they become problems. Communication enabled with a RS485 serial port and the Modbus protocol support, more communication options with the gateway H8951. The meter need to be powered by a 90V AC to 277V AC supply source. Include 2 21-CTs board strips with 1inch (26mm) spacing between each CT connectors, for 42 circuits. The device dimensions are 228mm in width, 146mm in height and weight 1.5 kilograms.
View AllClose