Schneider Electric

Schneider Electric BCPMB236S BCPM power monitoring intermediate - 36 solid core 100 A - 18 mm CT spacing

(No reviews yet) Write a Review
SKU:
BCPMB236S
MPN:
BCPMB236S
Condition:
New
Provided Equipment:
36 x current transformer
Type Of Measurement:
voltage || current || frequency || active power || power factor || active energy
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Product Or Component Type:
multi-circuit energy meter
Country of Origin:
United States
Variant:
intermediate
Energy Management:
sub billing and cost allocation
Device Application:
sub billing
Measurement Accuracy:
branch current 2 % 0.25…2 A || branch current 1 % 2…100 A || mains current 3 % 1…100 % || mains current 3 % 2…100 % || voltage 1 % 90…277 V
Product Certifications:
UL
Communication Port Support:
RS485
Ambient Air Temperature For Storage:
-40-70°C
Product Name:
PowerLogic BCPM
Operating Altitude:
9842.52 ft (3000 m)
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Communication Port Protocol:
Modbus RTU
China Rohs Regulation:
X
Update Time:
1.8 s
Eu Rohs Directive:
Compliant with Exemptions
Net Weight:
1.5 kg
Device Short Name:
BCPMB
Relative Humidity:
0-95 % 0-60°C
Mounting Mode:
panel-mounted
Connection Pitch:
18 mm
Power Quality Analysis:
voltage sag and swell detection
Power Monitoring:
basic instrumentation
Communication Of Data:
high-high current alarm || low-low current alarm || high current alarm || low current alarm || under voltage alarm || over voltage alarm
Weight:
1.5 kg
[Us] Rated Supply Voltage:
90...277 V AC 50/60 Hz +/- 1 %
Network Frequency:
60 Hz || 50 Hz
Mercury Free:
Yes
Range:
PowerLogic
Measurement Voltage:
90-277 V phase to neutral || 150-480 V phase to phase
Mounting Support:
panel || enclosure
Sampling Rate:
256 samples/cycle
Standards:
IEC 61036 || EN 61010 || UL 508 || ANSI C12.1
California Proposition 65:
WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
Analogue Input Type:
solid core CT 100 A36 x
Rohs Exemption Information:
Yes
$5,729.16

Description

This is an integrated solution for monitoring multi-circuits and mains by using a single meter. The meter is designed for use in new build and is used for critical power operations in data centres and energy management in buildings. It offers class 1 (1 %) power and energy system accuracy (100A solid core current transformers) on all branch channels. The BCPM monitors both the 36 branch circuits and mains values and only the mains incoming power and energy. All to provide information on the complete Power Distribution Unit. Full alarming capabilities ensure that potential issues are dealt with before they become problems. Communication enabled with a RS485 serial port and the Modbus protocol support, more communication options with the gateway H8951. The meter need to be powered by a 90V AC to 277V AC supply source. Include 2 18-CTs board strips with 18mm spacing between each CT connectors, for 36 circuits. The device dimensions are 228mm in width, 146mm in height and weight 1.5 kilograms.
View AllClose