Schneider Electric

Schneider Electric BCPMB272S BCPM power monitoring intermediate - 72 solid core 100 A - 18 mm CT spacing

(No reviews yet) Write a Review
SKU:
BCPMB272S
MPN:
BCPMB272S
Condition:
New
Mounting Mode:
panel-mounted
Range:
PowerLogic
Type Of Measurement:
voltage || current || frequency || active power || power factor || active energy
Communication Of Data:
over voltage alarm || high-high current alarm || under voltage alarm || high current alarm || low current alarm || low-low current alarm
Ambient Air Temperature For Storage:
-40-70°C
Device Short Name:
BCPMB
Energy Management:
sub billing and cost allocation
Power Quality Analysis:
voltage sag and swell detection
[Us] Rated Supply Voltage:
90...277 V AC 50/60 Hz +/- 1 %
Rohs Exemption Information:
Yes
California Proposition 65:
WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
Eu Rohs Directive:
Compliant with Exemptions
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Net Weight:
1.5 kg
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Network Frequency:
50 Hz || 60 Hz
Device Application:
sub billing
Update Time:
1.8 s
Product Or Component Type:
multi-circuit energy meter
Product Name:
PowerLogic BCPM
Provided Equipment:
72 x current transformer
Standards:
EN 61010 || IEC 61036 || ANSI C12.1 || UL 508
Operating Altitude:
9842.52 ft (3000 m)
Connection Pitch:
18 mm
Product Certifications:
UL
Relative Humidity:
0-95 % 0-60°C
Mercury Free:
Yes
China Rohs Regulation:
X
Sampling Rate:
256 samples/cycle
Measurement Voltage:
90-277 V phase to neutral || 150-480 V phase to phase
Country of Origin:
United States
Weight:
1.5 kg
Analogue Input Type:
solid core CT 100 A72 x
Variant:
intermediate
Communication Port Support:
RS485
Power Monitoring:
basic instrumentation
Communication Port Protocol:
Modbus RTU
Measurement Accuracy:
branch current 2 % 0.25…2 A || branch current 1 % 2…100 A || mains current 3 % 1…100 % || mains current 3 % 2…100 % || voltage 1 % 90…277 V
Mounting Support:
enclosure || panel
$8,918.90

Description

This is an integrated solution for monitoring multi-circuits and mains by using a single meter. The meter is designed for use in new build and is used for critical power operations in data centres and energy management in buildings. It offers class 1 (1 %) power and energy system accuracy (100A solid core current transformers) on all branch channels. The BCPM monitors both the 72 branch circuits and mains values and only the mains incoming power and energy. All to provide information on the complete Power Distribution Unit. Full alarming capabilities ensure that potential issues are dealt with before they become problems. Communication enabled with a RS485 serial port and the Modbus protocol support, more communication options with the gateway H8951. The meter need to be powered by a 90V AC to 277V AC supply source. Include 4 18-CTs board strips with 18mm spacing between each CT connectors, for 72 circuits. The device dimensions are 228mm in width, 146mm in height and weight 1.5 kilograms.
View AllClose