Schneider Electric

Schneider Electric BCPMC042S BCPM power monitoring basic - 42 solid core 100 A - 19 mm CT spacing

(No reviews yet) Write a Review
SKU:
BCPMC042S
MPN:
BCPMC042S
Condition:
New
Measurement Voltage:
90-277 V phase to neutral || 150-480 V phase to phase
Weight:
1.5 kg
Standards:
UL 508 || IEC 61036 || EN 61010 || ANSI C12.1
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Country of Origin:
United States
Connection Pitch:
19 mm
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Range:
PowerLogic
Communication Port Support:
RS485
Mercury Free:
Yes
China Rohs Regulation:
X
Provided Equipment:
42 x current transformer || 2 x cables
Warranty:
18 months
Update Time:
1.8 s
Communication Of Data:
low current alarm || low-low current alarm || high-high current alarm || high current alarm
Ambient Air Temperature For Storage:
-40-70°C
Product Name:
PowerLogic BCPM
Network Frequency:
50 Hz || 60 Hz
Product Or Component Type:
multi-circuit energy meter
Mounting Support:
panel || enclosure
California Proposition 65:
WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
Operating Altitude:
9842.52 ft (3000 m)
Measurement Accuracy:
current 2 % 0.25…2 A || current 1 % 2…100 A
Mounting Mode:
panel-mounted
Net Weight:
1.5 kg
Communication Port Protocol:
Modbus RTU
Analogue Input Type:
solid core CT 100 A42 x
Variant:
basic
Energy Management:
sub billing and cost allocation
Sampling Rate:
256 samples/cycle
Product Certifications:
UL
Eu Rohs Directive:
Compliant with Exemptions
Device Application:
sub billing
[Us] Rated Supply Voltage:
90...277 V AC 50/60 Hz +/- 1 %
Relative Humidity:
0-95 % 0-60°C
Power Monitoring:
basic instrumentation
Rohs Exemption Information:
Yes
Type Of Measurement:
current
Device Short Name:
BCPMC
$5,027.89

Description

This is an integrated solution for monitoring multi-circuits and mains by using a single meter. The meter is designed for use in new build and is used for critical power operations in data centres and energy management in buildings. It offers class 1 (1 %) power and energy system accuracy (100A solid core current transformers) on all branch channels. The BCPM monitors only the 42 branch circuits current. All to provide information on the complete Power Distribution Unit. Full alarming capabilities ensure that potential issues are dealt with before they become problems. Communication enabled with a RS485 serial port and the Modbus protocol support, more communication options with the gateway H8951. The meter need to be powered by a 90V AC to 277V AC supply source. Include 2 21-CTs board strips with 3/4inch (19mm) spacing between each CT connectors, for 42 circuits. The device dimensions are 228mm in width, 146mm in height and weight 1.5 kilograms.
View AllClose