Schneider Electric

Schneider Electric BCPMC084S BCPM power monitoring basic - 84 solid core 100 A - 19 mm CT spacing

(No reviews yet) Write a Review
SKU:
BCPMC084S
MPN:
BCPMC084S
Condition:
New
Product Name:
PowerLogic BCPM
Measurement Accuracy:
current 2 % 0.25…2 A || current 1 % 2…100 A
Weight:
1.5 kg
Energy Management:
sub billing and cost allocation
Ambient Air Temperature For Storage:
-40-70°C
Sampling Rate:
256 samples/cycle
[Us] Rated Supply Voltage:
90...277 V AC 50/60 Hz +/- 1 %
Analogue Input Type:
solid core CT 100 A84 x
Product Or Component Type:
multi-circuit energy meter
Provided Equipment:
84 x current transformer || 4 x cables
Operating Altitude:
9842.52 ft (3000 m)
Relative Humidity:
0-95 % 0-60°C
Type Of Measurement:
current
Communication Port Support:
RS485
Communication Port Protocol:
Modbus RTU
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Warranty:
18 months
California Proposition 65:
WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
Power Monitoring:
basic instrumentation
Product Certifications:
UL
Range:
PowerLogic
Communication Of Data:
high-high current alarm || low-low current alarm || high current alarm || low current alarm
Mounting Support:
panel || enclosure
Rohs Exemption Information:
Yes
Mercury Free:
Yes
Device Application:
sub billing
Update Time:
1.8 s
Connection Pitch:
19 mm
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Network Frequency:
60 Hz || 50 Hz
Net Weight:
1.5 kg
Measurement Voltage:
90-277 V phase to neutral || 150-480 V phase to phase
Eu Rohs Directive:
Compliant with Exemptions
Device Short Name:
BCPMC
Mounting Mode:
panel-mounted
Standards:
UL 508 || IEC 61036 || EN 61010 || ANSI C12.1
China Rohs Regulation:
X
Country of Origin:
United States
Variant:
basic
$7,542.60

Description

This is an integrated solution for monitoring multi-circuits and mains by using a single meter. The meter is designed for use in new build and is used for critical power operations in data centres and energy management in buildings. It offers class 1 (1 %) power and energy system accuracy (100A solid core current transformers) on all branch channels. The BCPM monitors only the 84 branch circuits current. All to provide information on the complete Power Distribution Unit. Full alarming capabilities ensure that potential issues are dealt with before they become problems. Communication enabled with a RS485 serial port and the Modbus protocol support, more communication options with the gateway H8951. The meter need to be powered by a 90V AC to 277V AC supply source. Include 4 21-CTs board strips with 3/4inch (19mm) spacing between each CT connectors, for 84 circuits. The device dimensions are 228mm in width, 146mm in height and weight 1.5 kilograms.