Schneider Electric

Schneider Electric BCPMC184S BCPM power monitoring basic - 84 solid core 100 A - 26 mm CT spacing

(No reviews yet) Write a Review
SKU:
BCPMC184S
MPN:
BCPMC184S
Condition:
New
Sampling Rate:
256 samples/cycle
Relative Humidity:
0-95 % 0-60°C
Communication Of Data:
low current alarm || low-low current alarm || high-high current alarm || high current alarm
Energy Management:
sub billing and cost allocation
Operating Altitude:
9842.52 ft (3000 m)
Country of Origin:
Mexico
China Rohs Regulation:
X
Analogue Input Type:
solid core CT 100 A84 x
Connection Pitch:
26 mm
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Communication Port Protocol:
Modbus RTU
Measurement Accuracy:
current 2 % 0.25…2 A || current 1 % 2…100 A
Eu Rohs Directive:
Compliant with Exemptions
Range:
PowerLogic
Product Or Component Type:
multi-circuit energy meter
Device Short Name:
BCPMC
Standards:
ANSI C12.1 || UL 508 || EN 61010 || IEC 61036
Measurement Voltage:
90-277 V phase to neutral || 150-480 V phase to phase
Device Application:
sub billing
Communication Port Support:
RS485
Provided Equipment:
84 x current transformer || 4 x cables
Ambient Air Temperature For Storage:
-40-70°C
Product Name:
PowerLogic BCPM
Variant:
basic
Product Certifications:
UL
Rohs Exemption Information:
Yes
Net Weight:
1.5 kg
Warranty:
18 months
Network Frequency:
50 Hz || 60 Hz
Mounting Mode:
panel-mounted
California Proposition 65:
WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Weight:
1.5 kg
Mounting Support:
panel || enclosure
[Us] Rated Supply Voltage:
90...277 V AC 50/60 Hz +/- 1 %
Mercury Free:
Yes
Type Of Measurement:
current
Power Monitoring:
basic instrumentation
Update Time:
1.8 s
$7,542.60

Description

This is an integrated solution for monitoring multi-circuits and mains by using a single meter. The meter is designed for use in new build and is used for critical power operations in data centres and energy management in buildings. It offers class 1 (1 %) power and energy system accuracy (100A solid core current transformers) on all branch channels. The BCPM monitors only the 84 branch circuits current. All to provide information on the complete Power Distribution Unit. Full alarming capabilities ensure that potential issues are dealt with before they become problems. Communication enabled with a RS485 serial port and the Modbus protocol support, more communication options with the gateway H8951. The meter need to be powered by a 90V AC to 277V AC supply source. Include 4 21-CTs board strips with 1inch (26mm) spacing between each CT connectors, for 84 circuits. The device dimensions are 228mm in width, 146mm in height and weight 1.5 kilograms.
View AllClose