Schneider Electric

Schneider Electric BCPMSCC60S BCPM power monitoring basic - 60 split core CT 50 A

(No reviews yet) Write a Review
SKU:
BCPMSCC60S
MPN:
BCPMSCC60S
Condition:
New
Weight:
1.5 kg
Warranty:
18 months
California Proposition 65:
WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
Mounting Mode:
clip-on
Network Frequency:
60 Hz || 50 Hz
Power Monitoring:
basic instrumentation
Range:
PowerLogic
Analogue Input Type:
split core CT 0.333 V60 x
Product Name:
PowerLogic BCPMSC
[Us] Rated Supply Voltage:
90...277 V AC 50/60 Hz +/- 1 %
Mounting Support:
board
Communication Port Protocol:
Modbus RTU
Communication Of Data:
high-high current alarm || low current alarm || high current alarm || low-low current alarm
Relative Humidity:
0-95 % 0-60°C
Variant:
basic
Eu Rohs Directive:
Compliant
Update Time:
1.8 s
Type Of Measurement:
current
Measurement Voltage:
90-277 V phase to neutral || 150-480 V phase to phase
Ambient Air Temperature For Storage:
-40-70°C
Device Short Name:
BCPMSCC
Provided Equipment:
4 x cables || 4 x adapter board || 60 x current transformer
Country of Origin:
United States
Net Weight:
1.5 kg
Communication Port Support:
RS485
Standards:
ANSI C12.1 || IEC 61036 || UL 508 || EN 61010
Device Application:
sub billing
Product Certifications:
UL
Measurement Accuracy:
current 2 % 0.25…2 A || current 1 % 2…100 A
Operating Altitude:
9842.52 ft (3000 m)
Sampling Rate:
256 samples/cycle
Product Or Component Type:
multi-circuit energy meter
Energy Management:
sub billing and cost allocation
$9,201.57

Description

This is an integrated solution for monitoring multi-circuits and mains by using a single meter. The meter is designed for retrofit and is used for critical power operations in data centres and energy management in buildings. It offers class 1 (1 %) power and energy system accuracy (including 50A, 100A or 200A split-core current transformers) on all branch channels. The BCPM monitors only the 60 branch circuits current. All to provide information on the complete Power Distribution Unit. Adapter boards with terminals for split-core CTs can be mounted using DIN-rail, Snaptrack or on a common mounting plate with the main board Full alarming capabilities ensure that potential issues are dealt with before they become problems. Communication enabled with a RS485 serial port and the Modbus protocol support, more communication options with the gateway H8951. The meter need to be powered by a 90V AC to 277V AC supply source. Include 50A branch CTs with 2 meters leads and 1.8 meters round ribbon cables, for 60 split-core current transformers. The device dimensions are 228mm in width, 146mm in height and weight 1.5 kilograms.