Schneider Electric BCPMSCC84S BCPM power monitoring basic - 84 split core CT 50 A

(No reviews yet) Write a Review
SKU:
BCPMSCC84S
MPN:
BCPMSCC84S
Condition:
New
California Proposition 65:
WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
Sampling Rate:
256 samples/cycle
Measurement Accuracy:
current 2 % 0.25…2 A || current 1 % 2…100 A
Product Or Component Type:
multi-circuit energy meter
Device Application:
sub billing
Ambient Air Temperature For Storage:
-40-70°C
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Mercury Free:
Yes
Weight:
1.5 kg
Range:
PowerLogic
Operating Altitude:
9842.52 ft (3000 m)
Analogue Input Type:
split core CT 0.333 V84 x
Mounting Mode:
clip-on
Rohs Exemption Information:
Yes
China Rohs Regulation:
X
Country of Origin:
United States
Warranty:
18 months
Provided Equipment:
84 x current transformer || 4 x cables || 4 x adapter board
Update Time:
1.8 s
Energy Management:
sub billing and cost allocation
Device Short Name:
BCPMSCC
Eu Rohs Directive:
Compliant with Exemptions
Communication Port Support:
RS485
Communication Port Protocol:
Modbus RTU
Communication Of Data:
low current alarm || low-low current alarm || high-high current alarm || high current alarm
Measurement Voltage:
90-277 V phase to neutral || 150-480 V phase to phase
Product Name:
PowerLogic BCPMSC
Power Monitoring:
basic instrumentation
Mounting Support:
board
Relative Humidity:
0-95 % 0-60°C
Variant:
basic
Product Certifications:
UL
Standards:
ANSI C12.1 || UL 508 || IEC 61036 || EN 61010
Type Of Measurement:
current
Net Weight:
1.5 kg
Network Frequency:
50 Hz || 60 Hz
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
[Us] Rated Supply Voltage:
90...277 V AC 50/60 Hz +/- 1 %
$11,140.10

Description

This is an integrated solution for monitoring multi-circuits and mains by using a single meter. The meter is designed for retrofit and is used for critical power operations in data centres and energy management in buildings. It offers class 1 (1 %) power and energy system accuracy (including 50A, 100A or 200A split-core current transformers) on all branch channels. The BCPM monitors only the 84 branch circuits current. All to provide information on the complete Power Distribution Unit. Adapter boards with terminals for split-core CTs can be mounted using DIN-rail, Snaptrack or on a common mounting plate with the main board Full alarming capabilities ensure that potential issues are dealt with before they become problems. Communication enabled with a RS485 serial port and the Modbus protocol support, more communication options with the gateway H8951. The meter need to be powered by a 90V AC to 277V AC supply source. Include 50A branch CTs with 2 meters leads and 1.8 meters round ribbon cables, for 84 split-core current transformers. The device dimensions are 228mm in width, 146mm in height and weight 1.5 kilograms.