Schneider Electric BDA260452 Molded Case Circuit Breaker 600Y/347V 45

(No reviews yet) Write a Review
SKU:
BDA260452
UPC:
3606486118832
Condition:
New
Halogen Content Performance:
Halogen free product
Local Signalling:
presence of auxiliary contacts flag green)
Depth:
89 mm
Color:
Gray RAL 7016)
Breaking Capacity Code:
D
Control Type:
toggle
Pollution Degree:
3 IEC 60947-1
Breaking Capacity:
25 kA 208Y/120 V AC 50/60 Hz UL 489 || 25 kA 240 V AC 50/60 Hz UL 489 || 18 kA 480/277 V AC 50/60 Hz UL 489 || 18 kA 480 V AC 50/60 Hz UL 489 || 14 kA 600Y/347 V AC 50/60 Hz UL 489 || 10 kA 250 V DC UL 489
Poles Description:
2P
Electrical Durability:
10000 cycles IEC 947-1 Annex K ed 5.2 440 V In
Suitability For Isolation:
yes IEC 60947-2
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Number Of Slots:
1 auxiliary switch OF plug-in) || 1 voltage release MN or MX plug-in)
Quantity Per Set:
set of 1
Phase Connection:
AC
Rohs Exemption Information:
Yes
Height:
137 mm
Device Short Name:
BD 045
Electrical Connection:
I-Line connection, line || lugs, load
Pvc Free:
Yes
Net Weight:
0.952 kg
Ambient Air Temperature For Operation:
-25-70 °C
[Ue] Rated Operational Voltage:
525 V AC 50/60 Hz UL 489
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
Mercury Free:
Yes
Ambient Air Temperature For Storage:
-50-85 °C
Quality Labels:
CE
Mounting Height:
76.2 mm
Product Name:
PowerPact B
Environmental Disclosure:
ENVPEP1610005EN
[Ics] Rated Service Breaking Capacity:
25 kA 220...240 V AC 50/60 Hz IEC 60947-2 || 14 kA 500...525 V AC 50/60 Hz IEC 60947-2 || 18 kA 380...415 V AC 50/60 Hz IEC 60947-2 || 18 kA 440 V AC 50/60 Hz IEC 60947-2
Wire Stripping Length:
20 mm
[Ui] Rated Insulation Voltage:
800 V IEC 60947-2
Mounting Mode:
I-Line
Utilisation Category:
category A
Range:
PowerPact
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Circuit Breaker Application:
HACR rated
Network Frequency:
50/60 Hz
Device Application:
distribution
Sustainable Offer Status:
Green Premium product
Trip Unit Technology:
thermal-magnetic
Line Rated Current:
45-45 A
Standards:
EN/IEC 60947-5-1 || NMX J-266 || EN/IEC 60947-2 || GB 14048.2 || UL 489 || CSA C22.2 No 5 || NEMA AB1
Tightening Torque:
3.6-4.4 N.m 2.5-6 mm² (AWG 14...AWG 10) || 5-6.2 N.m 10-70 mm² (AWG 8...AWG 2/0)
Ik Degree Of Protection:
IK07 IEC 62262
Connection Pitch:
27 mm
Width:
54 mm
Awg Gauge:
AWG 14...AWG 2/0 aluminium/copper
Continuous Current Rating:
0.8
Product Certifications:
UL || IEC || CCC || EAC || CSA || NOM
Ip Degree Of Protection:
front cover IP40 IEC 60529
9 Mm Pitches:
6
Eu Rohs Directive:
Compliant
Product Or Component Type:
circuit breaker
Mechanical Durability:
20000 cycles IEC 947-1 Annex K ed 5.2
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Brochure:
View
Catalog:
View
Datasheet:
View
  • Schneider Electric BDA260452 Molded Case Circuit Breaker 600Y/347V 45
  • Schneider Electric BDA260452 Molded Case Circuit Breaker 600Y/347V 45
  • Schneider Electric BDA260452 Molded Case Circuit Breaker 600Y/347V 45
$1,215.00

Description

PowerPacT B-Frame brings thermal-mechanical circuit protection in a compact size and offers a wide range of accessories, auxiliaries, and connection options. This PowerPacT B-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 14kA at 600Y/347VAC. All PowerPacT B-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT B-Frame circuit breakers come in 1 to 4-pole unit mount construction and in 1 to 3-pole I-Line construction. I-Line circuit breakers come with a shrouded I-Line plug on jaw. This unit has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT B, 45A, 2 pole, circuit breaker has a breaking capacity of 14kA at 600Y/347VAC. This circuit breaker has a continuous current rating of 80% with an AC phase connection. PowerPacT B circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.