Schneider Electric BGF26070 Molded Case Circuit Brkr 600Y/347V 70A

(No reviews yet) Write a Review
SKU:
BGF26070
UPC:
3606481193230
Condition:
New
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Connection Pitch:
27 mm
Quantity Per Set:
set of 1
Net Weight:
0.669 kg
Ambient Air Temperature For Operation:
-25-70 °C
Breaking Capacity Code:
G
Operating Altitude:
6561.68 ft (2000 m) without derating || 5000 m with derating
Quality Labels:
CE
Ik Degree Of Protection:
IK07 IEC 62262
[Ue] Rated Operational Voltage:
525 V AC 50/60 Hz UL 489
Product Or Component Type:
circuit breaker
Number Of Slots:
1 auxiliary switch OF plug-in) || 1 voltage release MN or MX plug-in)
Trip Unit Technology:
thermal-magneticTM-D,
Environmental Disclosure:
ENVPEP1610005EN
Awg Gauge:
AWG 14...AWG 8 aluminium/copper || AWG 6...AWG 3/0 aluminium/copper
Color:
Gray RAL 7016)
Mercury Free:
Yes
Circuit Breaker Application:
HACR rated
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Product Name:
PowerPact B
Pollution Degree:
3 IEC 60947-1
Circularity Profile:
N/A
Utilisation Category:
category A
Electrical Connection:
terminal nut, ON and OFF end
Device Application:
distribution
Mechanical Durability:
15000 cycles IEC 947-1 Annex K ed 5.2
[Ui] Rated Insulation Voltage:
800 V IEC 60947-2
Width:
54 mm
Local Signalling:
presence of auxiliary contacts flag green)
Poles Description:
2P
Eu Rohs Directive:
Compliant with Exemptions
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Product Certifications:
UL || IEC || CCC || EAC || CSA || NOM
Standards:
UL 489 || NEMA AB1 || EN/IEC 60947-2 || CSA C22.2 No 5 || GB 14048.2 || EN/IEC 60947-5-1 || NMX J-266
Suitability For Isolation:
yes IEC 60947-2
Height:
137 mm
Breaking Capacity:
65 kA 208Y/120 V AC 50/60 Hz UL 489 || 65 kA 240 V AC 50/60 Hz UL 489 || 35 kA 480/277 V AC 50/60 Hz UL 489 || 35 kA 480 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489 || 18 kA 600Y/347 V AC 50/60 Hz UL 489
Trip Unit Name:
TM-D
Tightening Torque:
5-5 N.m 2.5-16 mm² (AWG 14...AWG 4) || 9-9 N.m 25-95 mm² (AWG 3...AWG 3/0)
Ip Degree Of Protection:
front cover IP40 IEC 60529
Depth:
80 mm
Sustainable Offer Status:
Green Premium product
Wire Stripping Length:
20 mm
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Ambient Air Temperature For Storage:
-50-85 °C
Device Short Name:
BG 070
Mounting Mode:
clip-on 35 mm symmetrical DIN rail) || by screws plate)
Control Type:
toggle
Network Frequency:
50/60 Hz
Electrical Durability:
10000 cycles IEC 947-1 Annex K ed 5.2 440 V In
Pvc Free:
Yes
Continuous Current Rating:
0.8
Protected Poles Description:
2t
Halogen Content Performance:
Halogen free product
Rohs Exemption Information:
Yes
9 Mm Pitches:
6
Range:
PowerPact
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Line Rated Current:
70-70 A
[Ics] Rated Service Breaking Capacity:
65 kA 220...240 V AC 50/60 Hz IEC 60947-2 || 18 kA 500...525 V AC 50/60 Hz IEC 60947-2 || 35 kA 380...415 V AC 50/60 Hz IEC 60947-2 || 35 kA 440 V AC 50/60 Hz IEC 60947-2
  • Schneider Electric BGF26070 Molded Case Circuit Brkr 600Y/347V 70A
  • Schneider Electric BGF26070 Molded Case Circuit Brkr 600Y/347V 70A
  • Schneider Electric BGF26070 Molded Case Circuit Brkr 600Y/347V 70A
$2,569.50

Description

PowerPacT B-Frame brings thermal-mechanical circuit protection in a compact size and offers a wide range of accessories, auxiliaries, and connection options. This PowerPacT B-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 18kA at 600Y/347VAC. All PowerPacT B-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT B-Frame circuit breakers come in 1 to 4-pole unit mount construction and in 1 to 3-pole I-Line construction. This circuit breaker's unit mount construction features traditional back pan mounting with screws or integrated DIN rail mounting for installation flexibility. This unit has terminal nuts on both termination ends. This PowerPacT B, 70A, 2 pole, circuit breaker has a breaking capacity of 18kA at 600Y/347VAC. This circuit breaker has a continuous current rating of 80%. PowerPacT B circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked. EverLink lugs are also available with unique integrated control wire terminals.
View AllClose