Schneider Electric

Schneider Electric BJF36090 Circuit breaker, PowerPacT B, 90A, 3 pole, 600Y/347VAC, 25kA, terminal nut, thermal magnetic, 80%

(No reviews yet) Write a Review
SKU:
BJF36090
MPN:
BJF36090
Condition:
New
Weight:
0.924 kg
Network Frequency:
50/60 Hz
Protected Poles Description:
3t
Operating Altitude:
6561.68 ft (2000 m) without derating || 5000 m with derating
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz UL 489
Rohs Exemption Information:
Yes
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Standards:
NMX J-266 || UL 489 || GB 14048.2 || EN/IEC 60947-5-1 || EN/IEC 60947-2 || NEMA AB1 || CSA C22.2 No 5
Local Signaling:
presence of auxiliary contacts flag green)
Ambient Air Temperature For Storage:
-50-85°C
Country of Origin:
United States
Product Certifications:
UL || IEC || CCC || EAC || CSA || NOM
[Ui] Rated Insulation Voltage:
800 V IEC 60947-2
Wire Stripping Length:
20 mm
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Electrical Durability:
10000 cycles IEC 947-1 Annex K ed 5.2 440 V In
Ambient Air Temperature For Operation:
-25-70°C
Circuit Breaker Application:
HACR rated
Suitability For Isolation:
yes IEC 60947-2
Continuous Current Rating:
0.8
Device Short Name:
BJ 090
Number Of Slots:
1 auxiliary switch OF plug-in) || 1 voltage release MN or MX plug-in) || 1 alarm switch SD plug-in)
Trip Unit Technology:
thermal-magneticTM-D,
Device Application:
distribution
Utilisation Category:
category A
Height:
137 mm
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Product Name:
PowerPact B
Length:
20 mm
Pvc Free:
Yes
Product Or Component Type:
circuit breaker
9 Mm Pitches:
9
Mounting Mode:
clip-on 35 mm symmetrical DIN rail) || by screws plate)
Poles Description:
3P
Quality Labels:
CE
Halogen Content Performance:
Halogen free product
Control Type:
toggle
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Sustainable Offer Status:
Green Premium product
Electrical Connection:
terminal nut, ON and OFF end
Environmental Disclosure:
ENVPEP2311047EN
Breaking Capacity:
100 kA 208Y/120 V AC 50/60 Hz UL 489 || 100 kA 240 V AC 50/60 Hz UL 489 || 65 kA 480/277 V AC 50/60 Hz UL 489 || 65 kA 480 V AC 50/60 Hz UL 489 || 25 kA 600Y/347 V AC 50/60 Hz UL 489 || 50 kA 250 V DC UL 489
Quantity Per Set:
set of 1
Eu Rohs Directive:
Compliant with Exemptions
Awg Gauge:
AWG 14...AWG 8 aluminium/copper || AWG 6...AWG 3/0 aluminium/copper
Ik Degree Of Protection:
IK07 conforming to IEC 62262
Ip Degree Of Protection:
front cover IP40 IEC 60529
$1,889.00