I²T On Activation:
2.5 A².s 125 V
Product Or Component Type:
power supply module
Immunity To Microbreaks:
1 ms
Protection Type:
internal fuse not accessible primary circuit || overload protection secondary circuit || overvoltage protection secondary circuit || short-circuit protection secondary circuit
Electrical Connection:
1 connector 2 alarm relay || 1 connector 5 line supply, protective earth
Primary Voltage:
125 V
Maximum Power Dissipation In W:
8.5 W
Range Of Product:
Modicon X80
Primary Voltage Limit:
100...150 V
Mtbf Reliability:
830000 H
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Protective Treatment:
conformal coating
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Country of Origin:
United States
Mercury Free:
Yes
Current At Secondary Voltage:
1.67 A 24 V DC I/O module power supply and processor || 5 A 3.3 V DC I/O module logic power supply
Secondary Power:
18 W 3.3 V DC -25-70°C I/O module logic power supply || 40 W 24 V DC -25-70°C I/O module power supply and processor if 3.3 V not loaded
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
China Rohs Regulation:
X
Insulation Resistance:
>= 100 MOhm primary/ground || >= 100 MOhm primary/secondary
Status Led:
1 LED (Green) presence of voltages (OK) || 1 LED (Green) redundancy OK || 1 LED (Green) power supply status
Dielectric Strength:
1500 V primary/secondary I/O module logic power supply || 1500 V primary/secondary I/O module power supply and processor || 2300 V primary/secondary sensor power supply || 1500 V primary/ground
Product Certifications:
CE || UL || CSA || RCM || EAC || Merchant Navy
Supply Circuit Type:
DC
Ambient Air Temperature For Operation:
-25-70°C
Relative Humidity:
10-95 % without condensation
Environmental Characteristic:
gas resistant class Gx ISA S71.04 || gas resistant class 3C4 IEC 60721-3-3 || dust resistant class 3S4 IEC 60721-3-3 || sand resistant class 3S4 IEC 60721-3-3 || salt resistant level 2 IEC 68252 || mold growth resistant class 3B2 IEC 60721-3-3 || fun
Net Weight:
0.61 kg
It On Activation:
0.09 A.s 125 V
Function Available:
temperature sensing || redundancy information || redundancy test || uptime duration || remaining lifetime
Control Type:
RESET push-button cold restart
Ambient Air Temperature For Storage:
-40-85°C
Input Current:
600 mA 125 V
Ip Degree Of Protection:
IP20
Standards:
EN 61131-2 || EN/IEC 61010-2-201 || UL 61010-2-201 || CSA C22.2 No 61010-2-201 || IACS E10 || EN/IEC 61000-6-5, interface type 1 and type 2 || EN/IEC 61850-3, location G
Directives:
2014/35/EU - low voltage directive || 2014/30/EU - electromagnetic compatibility
Weight:
0.61 kg
California Proposition 65:
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Product Compatibility:
all backplane
Inrush Current:
60 A 125 V
Product Specific Application:
for severe environments