Schneider Electric CA2KN22B72 Control relay, TeSys K, 2 NO + 2 NC, lt or eq to 690V, 24VAC coil
SKU:
CA2KN22B72
UPC:
MPN:
CA2KN22B72
Condition:
New
Control Circuit Type:
AC 50/60 Hz
Flame Retardance:
V1 conforming to UL 94 || requirement 2 conforming to NF F 16-101 || requirement 2 conforming to NF F 16-102
Net Weight:
0.18 kg
Sustainable Offer Status:
Green Premium product
Range:
TeSys
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Standards:
EN/IEC 60947-4-1 || GB/T 14048.4 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || JIS C8201-4-1
Circularity Profile:
ENVEOLI1503003EN
Reach Free Of Svhc:
Yes
Tightening Torque:
1.3 N.m screw clamp terminals flat Ø 6 mm || 1.3 N.m screw clamp terminals Philips No 2 6 mm || 1.3 N.m screw clamp terminals pozidriv No 2
Connections - Terminals:
screw clamp terminals 1 1.5-4 mm²solid || screw clamp terminals 2 1.5-4 mm²solid || screw clamp terminals 1 0.75-4 mm²flexible with cable end || screw clamp terminals 2 0.75-4 mm²flexible without cable end || screw clamp terminals 1 0.34-1.5
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Protective Treatment:
TC IEC 60068
Minimum Switching Voltage:
17 V
Contactor Application:
control circuit
Irms Rated Making Capacity:
110 A IEC 60947
Device Short Name:
CA2K
Warranty:
18 months
Pole Contact Composition:
2 NO + 2 NC
Insulation Resistance:
> 10 MOhm
Operating Altitude:
6561.68 ft (2000 m) without derating
Product Name:
TeSys CAK
Rohs Exemption Information:
Yes
Ambient Air Temperature For Storage:
-50-80°C
Mounting Support:
plate || rail
Country of Origin:
France
Depth:
57 mm
Mechanical Robustness:
vibrations contactor open2 Gn, 5...300 Hz IEC 60068-2-6 || vibrations contactor closed4 Gn, 5...300 Hz IEC 60068-2-6 || shocks contactor open10 Gn for 11 ms IEC 60068-2-27 || shocks contactor closed15 Gn for 11 ms IEC 60068-2-27
[Uc] Control Circuit Voltage:
24 V AC 50/60 Hz
Operating Time:
10...20 ms coil de-energisation and NO opening || 10...20 ms coil energisation and NO closing || 15...25 ms coil de-energisation and NC closing || 5...15 ms coil energisation and NC opening
TeSys K control relay, 4 contacts (2NO + 2NC), 10A/690V, for control of electromagnetic loads AC-15/DC-13. It provides a 24V 50/60Hz AC control circuit, connection by spring terminals. For high...
TeSys K control relay, 4 contacts (2NO + 2NC), 10A/690V, for control of electromagnetic loads AC-15/DC-13. It provides a 24V 50/60Hz AC control circuit, connection by screw clamp terminals. For high...
TeSys K control relay, 4 contacts (2NO + 2NC), 10A/690V, for control of electromagnetic loads AC-15/DC-13. It provides a 24V DC control circuit with no inrush consumption and equipped with a surge...
TeSys K control relay, 4 contacts (2NO + 2NC), 10A/690V, for control of electromagnetic loads AC-15/DC-13. It provides a 48V DC control circuit with no inrush consumption, connection by screw clamp...
TeSys K control relay, 4 contacts (2NO + 2NC), 10A/690V, for control of electromagnetic loads AC-15/DC-13. It provides a 230-240V 50/60Hz AC control circuit, connection by screw clamp terminals. For...