Schneider Electric

Schneider Electric CA2KN22F72 Control relay, TeSys K, 2 NO + 2 NC, lt or eq to 690V, 110VAC coil

(No reviews yet) Write a Review
SKU:
CA2KN22F72
MPN:
CA2KN22F72
Condition:
New
Operating Time:
10...20 ms coil de-energisation and NO opening || 10...20 ms coil energisation and NO closing || 15...25 ms coil de-energisation and NC closing || 5...15 ms coil energisation and NC opening
Weight:
0.18 kg
Reach Free Of Svhc:
Yes
Device Short Name:
CA2K
Depth:
57 mm
[Uc] Control Circuit Voltage:
110 V AC 50/60 Hz
Ambient Air Temperature For Storage:
-50-80°C
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
[Ith] Conventional Free Air Thermal Current:
10 A (at 50°C)
Mounting Support:
rail || plate
Product Name:
TeSys CAK
Rohs Exemption Information:
Yes
Irms Rated Making Capacity:
110 A IEC 60947
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Maximum Operating Rate:
10000 cyc/h
Inrush Power In Va:
30-30 VA (at 20°C)
Minimum Switching Voltage:
17 V
Associated Fuse Rating:
10 A gG conforming to IEC 60947 || 10 A gG conforming to VDE 0660
Minimum Switching Current:
5 mA
Standards:
EN/IEC 60947-4-1 || GB/T 14048.4 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || JIS C8201-4-1
Insulation Resistance:
> 10 MOhm
Country of Origin:
France
Tightening Torque:
1.3 N.m screw clamp terminals flat Ø 6 mm || 1.3 N.m screw clamp terminals Philips No 2 6 mm || 1.3 N.m screw clamp terminals pozidriv No 2
Product Certifications:
CB Scheme || CCC || UL || CSA || EAC || CE || UKCA
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Toxic Heavy Metal Free:
Yes
Product Or Component Type:
control relay
Utilisation Category:
AC-15 || DC-13
Immunity To Microbreaks:
2 ms
Warranty:
18 months
Eu Rohs Directive:
Compliant
[Ui] Rated Insulation Voltage:
690 V IEC 60947 || 750 V VDE 0110 group C || 690 V BS 5424 || 600 V CSA C22.2 No 14
Mercury Free:
Yes
Mechanical Durability:
10 Mcycles
Flame Retardance:
V1 conforming to UL 94 || requirement 2 conforming to NF F 16-101 || requirement 2 conforming to NF F 16-102
Operating Altitude:
6561.68 ft (2000 m) without derating
Sustainable Offer Status:
Green Premium product
Non Overlap Distance:
0.5 mm
Ip Degree Of Protection:
IP2X
Range:
TeSys
Ambient Air Temperature For Operation:
-25-50°C
Protective Treatment:
TC IEC 60068
Control Circuit Voltage Limits:
drop-out: 0.2...0.75 Uc (at <50°C) || operational: 0.8...1.15 Uc (at <50°C)
Hold-In Power Consumption In Va:
4.5-4.5 VA (at 20°C)
Control Circuit Type:
AC 50/60 Hz
$45.90