- Operating Altitude:
- 6561.68 ft (2000 m) without derating
- Sustainable Offer Status:
- Green Premium product
- Mechanical Durability:
- 10000000 cycles
- Country of Origin:
- France
- Maximum Operating Rate:
- 10000 cyc/h 20°C
- Product Name:
- TeSys CAK
- Inrush Power In Va:
- 30-30 VA (at 20°C)
- Ip Degree Of Protection:
- IP2X conforming to VDE 0106
- Tightening Torque:
- 0.8-1.3 N.m screw clamp terminals 1.5-4 mm² Philips M6
- Operating Time:
- 10...20 ms coil de-energisation and NO opening || 10...20 ms coil energisation and NO closing || 15...25 ms coil de-energisation and NC closing || 5...15 ms coil energisation and NC opening
- Depth:
- 57 mm
- Product Certifications:
- UL || CSA || UKCA
- Associated Fuse Rating:
- 10 A gG <= 690 V IEC 60947 || 10 A gG <= 690 V VDE 0660
- Reach Regulation:
- Free of Substances of Very High Concern above the threshold
- Minimum Switching Current:
- 5 mA
- Control Circuit Type:
- AC
- Device Short Name:
- CA2K
- Coil Type:
- standard
- Coil Technology:
- without integral suppression device
- [Ue] Rated Operational Voltage:
- <= 690 V AC <= 400 Hz
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Eu Rohs Directive:
- Compliant
- Net Weight:
- 0.18 kg
- Flame Retardance:
- class C2 conforming to NF F 16-101 || class C2 conforming to NF F 16-102 || V1 conforming to UL 94
- Environmental Disclosure:
- ENVPEP1503003EN
- Non-Overlap Time:
- 1.5 ms on de-energisation between NC and NO contacts || 1.5 ms on energisation between NC and NO contacts
- Ambient Air Temperature For Storage:
- -50-80°C
- [Uc] Control Circuit Voltage:
- 480 V AC 50/60 Hz
- Width:
- 45 mm
- Product Or Component Type:
- control relay
- Protective Treatment:
- TC IEC 60068
- Toxic Heavy Metal Free:
- Yes
- [Ith] Conventional Free Air Thermal Current:
- 10 A (at 50°C)
- Ambient Air Temperature For Operation:
- -25-50°C
- Utilisation Category:
- AC-15
- Insulation Resistance:
- > 10 MOhm
- Rohs Exemption Information:
- Yes
- Warranty:
- 18 months
- Control Circuit Voltage Limits:
- drop-out: <= 0.2 Uc at 50/60 Hz (at <50°C) || operational: 0.8...1.15 Uc at 50/60 Hz (at <50°C)
- Immunity To Microbreaks:
- 2 ms
- Non Overlap Distance:
- 0.5 m
- Shock Resistance:
- 10 gn control relay open || 15 gn control relay closed
- Standards:
- VDE 0660 || NF C 63-140 || IEC 60947 || BS 5424
- Range:
- TeSys
- Vibration Resistance:
- 2 gn 5-300 Hz control relay open || 4 gn 5-300 Hz control relay closed
- Height:
- 58 mm
- China Rohs Regulation:
- Pro-active China RoHS declaration (out of China RoHS legal scope)
- Circularity Profile:
- ENVEOLI1503003EN
- Hold-In Power Consumption In Va:
- 4.5-4.5 VA (at 20°C)