Schneider Electric

Schneider Electric CAD323F7 TeSys Deca control relay - 3 NO + 2 NC - <= 690 V - 110 V AC standard coil

(No reviews yet) Write a Review
SKU:
CAD323F7
MPN:
CAD323F7
Condition:
New
Operating Altitude:
0...9842.52 ft (0...3000 m)
Standards:
EN/IEC 60947-5-1 || GB/T 14048.5 || UL 60947-5-1 || CSA C22.2 No 60947-5-1 || JIS C8201-5-1
Mercury Free:
Yes
Depth:
84 mm
Utilisation Category:
DC-13 || AC-15 || AC-14
Net Weight:
0.58 kg
Country of Origin:
United States
Mounting Support:
plate || rail
Eu Rohs Directive:
Compliant with Exemptions
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Environmental Disclosure:
ENVPEP1501004
Mechanical Robustness:
shocks control relay open10 Gn for 11 ms IEC 60068-2-27 || shocks control relay closed15 Gn for 11 ms IEC 60068-2-27 || vibrations control relay open2 Gn, 5...300 Hz IEC 60068-2-6 || vibrations control relay closed4 Gn, 5...300 Hz IEC 60068-2-6
[Icw] Rated Short-Time Withstand Current:
100 A - 1 s || 120 A - 500 ms || 140 A - 100 ms
[Ui] Rated Insulation Voltage:
600 V UL || 600 V CSA || 690 V IEC 60947-5-1
Product Name:
TeSys CAD
Product Or Component Type:
control relay
Ambient Air Temperature For Storage:
-60-80°C
Sustainable Offer Status:
Green Premium product
Control Circuit Type:
AC 50/60 Hz
Mechanical Durability:
30 Mcycles
Ambient Air Temperature For Operation:
-40-60°C || 60-70°C with derating
[Uimp] Rated Impulse Withstand Voltage:
6 kV IEC 60947
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Circularity Profile:
ENVEOLI1501004
[Ue] Rated Operational Voltage:
<= 690 V AC 25...400 Hz
[Ith] Conventional Free Air Thermal Current:
10 A (at 60°C)
Maximum Operating Rate:
180 cyc/mn
Hold-In Power Consumption In Va:
8-8 VA 50 Hz (at 20°C)
Operating Time:
12...22 ms coil energisation and NO closing || 4...12 ms coil de-energisation and NO opening || 4...19 ms coil energisation and NC opening || 6...17 ms coil de-energisation and NC closing
Device Short Name:
CAD
Associated Fuse Rating:
10 A gG conforming to IEC 60947-5-1
Control Circuit Voltage Limits:
0.3...0.6 Uc -40-70°C drop-out AC 50/60 Hz || 0.8...1.1 Uc -40-60°C operational AC 50 Hz || 0.85...1.1 Uc -40-60°C operational AC 60 Hz || 1...1.1 Uc 60-70°C operational AC 50/60 Hz
Rohs Exemption Information:
Yes
Connections - Terminals:
spring terminals 1 1-2.5 mm²flexible without cable end || spring terminals 2 1-2.5 mm²flexible without cable end || spring terminals 1 1-2.5 mm²solid without cable end || spring terminals 2 1-2.5 mm²solid without cable end
Minimum Switching Current:
5 mA
Protective Treatment:
TH IEC 60068
Pole Contact Composition:
3 NO + 2 NC
Contactor Application:
control circuit
Product Certifications:
CB || CCC || UL || CSA || EAC || CE || UKCA
Minimum Switching Voltage:
17 V
Ip Degree Of Protection:
IP2X front face VDE 0106
Range:
TeSys || TeSys Deca
Non-Overlap Time:
1.5 ms on energisation between NC and NO contact || 1.5 ms on de-energisation between NC and NO contact
Irms Rated Making Capacity:
140 A AC IEC 60947-5-1 || 250 A DC IEC 60947-5-1
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
$63.25

Description

TeSys D control relay, 5 contacts (3NO + 2NC), 10A/690V, for control of electromagnetic loads AC-15/DC-13. It provides a 110V 50/60Hz AC control circuit, connection by spring terminals. For high operating rates until 180 cycles/min and ambient temperature -40/+60°C, it procures high reliability and durability. Compact (45mm width), for clipping on 35mm DIN rail or fixing by screw. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium product (RoHS/REACh).