Schneider Electric

Schneider Electric CAD323G7 TeSys Deca control relay - 3 NO + 2 NC - <= 690 V - 120 V AC standard coil

(No reviews yet) Write a Review
SKU:
CAD323G7
MPN:
CAD323G7
Condition:
New
Control Circuit Type:
AC 50/60 Hz
Product Or Component Type:
control relay
Mercury Free:
Yes
[Ith] Conventional Free Air Thermal Current:
10 A (at 60°C)
Operating Time:
12...22 ms coil energisation and NO closing || 4...12 ms coil de-energisation and NO opening || 4...19 ms coil energisation and NC opening || 6...17 ms coil de-energisation and NC closing
Non-Overlap Time:
1.5 ms on energisation between NC and NO contact || 1.5 ms on de-energisation between NC and NO contact
Minimum Switching Voltage:
17 V
Weight:
0.58 kg
[Ui] Rated Insulation Voltage:
600 V UL || 600 V CSA || 690 V IEC 60947-5-1
[Uc] Control Circuit Voltage:
120 V DC
Mounting Support:
plate || rail
Product Name:
TeSys CAD
[Icw] Rated Short-Time Withstand Current:
100 A - 1 s || 120 A - 500 ms || 140 A - 100 ms
Maximum Operating Rate:
180 cyc/mn
Standards:
EN/IEC 60947-5-1 || GB/T 14048.5 || UL 60947-5-1 || CSA C22.2 No 60947-5-1 || JIS C8201-5-1
Warranty:
18 months
Ip Degree Of Protection:
IP2X front face VDE 0106
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Inrush Power In Va:
70-70 VA 50 Hz (at 20°C)
Ambient Air Temperature For Storage:
-60-80°C
Product Certifications:
CB || CCC || UL || CSA || EAC || CE || UKCA
Minimum Switching Current:
5 mA
Circularity Profile:
ENVEOLI1501004
Contactor Application:
control circuit
Irms Rated Making Capacity:
140 A AC IEC 60947-5-1 || 250 A DC IEC 60947-5-1
Protective Treatment:
TH IEC 60068
Device Short Name:
CAD
[Ue] Rated Operational Voltage:
<= 690 V AC 25...400 Hz
Country of Origin:
France
Control Circuit Voltage Limits:
0.3...0.6 Uc -40-70°C drop-out AC 50/60 Hz || 0.8...1.1 Uc -40-60°C operational AC 50 Hz || 0.85...1.1 Uc -40-60°C operational AC 60 Hz || 1...1.1 Uc 60-70°C operational AC 50/60 Hz
Operating Altitude:
0...9842.52 ft (0...3000 m)
[Uimp] Rated Impulse Withstand Voltage:
6 kV IEC 60947
Net Weight:
0.58 kg
Utilisation Category:
AC-14 || AC-15 || DC-13
Rohs Exemption Information:
Yes
Eu Rohs Directive:
Compliant with Exemptions
Depth:
84 mm
Insulation Resistance:
> 10 MOhm
Associated Fuse Rating:
10 A gG conforming to IEC 60947-5-1
Hold-In Power Consumption In Va:
8-8 VA 50 Hz (at 20°C)
Mechanical Robustness:
shocks control relay open10 Gn for 11 ms IEC 60068-2-27 || shocks control relay closed15 Gn for 11 ms IEC 60068-2-27 || vibrations control relay open2 Gn, 5...300 Hz IEC 60068-2-6 || vibrations control relay closed4 Gn, 5...300 Hz IEC 60068-2-6
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Environmental Disclosure:
ENVPEP1501004
Ambient Air Temperature For Operation:
-40-60°C || 60-70°C with derating
Pole Contact Composition:
3 NO + 2 NC
$63.25

Description

TeSys D control relay, 5 contacts (3NO + 2NC), 10A/690V, for control of electromagnetic loads AC-15/DC-13. It provides a 120V 50/60Hz AC control circuit, connection by spring terminals. For high operating rates until 180 cycles/min and ambient temperature -40/+60°C, it procures high reliability and durability. Compact (45mm width), for clipping on 35mm DIN rail or fixing by screw. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium product (RoHS/REACh).
View AllClose