Schneider Electric

Schneider Electric CAD326B7 TeSys Deca control relay - 3 NO + 2 NC - <= 690 V - 24 V AC standard coil

(No reviews yet) Write a Review
SKU:
CAD326B7
MPN:
CAD326B7
Condition:
New
Insulation Resistance:
> 10 MOhm
Connections - Terminals:
lugs-ring terminals 8 mm)
Associated Fuse Rating:
10 A gG conforming to IEC 60947-5-1
Mechanical Robustness:
shocks control relay open10 Gn for 11 ms IEC 60068-2-27 || shocks control relay closed15 Gn for 11 ms IEC 60068-2-27 || vibrations control relay open2 Gn, 5...300 Hz IEC 60068-2-6 || vibrations control relay closed4 Gn, 5...300 Hz IEC 60068-2-6
Device Short Name:
CAD
Ip Degree Of Protection:
IP2X front face VDE 0106
Product Or Component Type:
control relay
[Icw] Rated Short-Time Withstand Current:
100 A - 1 s || 120 A - 500 ms || 140 A - 100 ms
[Uimp] Rated Impulse Withstand Voltage:
6 kV IEC 60947
Sustainable Offer Status:
Green Premium product
Pole Contact Composition:
3 NO + 2 NC
Rohs Exemption Information:
Yes
Minimum Switching Voltage:
17 V
Product Name:
TeSys CAD
Operating Altitude:
0...9842.52 ft (0...3000 m)
[Uc] Control Circuit Voltage:
24 V AC 50/60 Hz
Maximum Operating Rate:
180 cyc/mn
Ambient Air Temperature For Storage:
-60-80°C
[Ui] Rated Insulation Voltage:
600 V UL || 600 V CSA || 690 V IEC 60947-5-1
[Ith] Conventional Free Air Thermal Current:
10 A (at 60°C)
Mercury Free:
Yes
Depth:
84 mm
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Warranty:
18 months
Operating Time:
12...22 ms coil energisation and NO closing || 4...12 ms coil de-energisation and NO opening || 4...19 ms coil energisation and NC opening || 6...17 ms coil de-energisation and NC closing
Product Certifications:
CB || CCC || UL || CSA || EAC || CE || UKCA
Circularity Profile:
ENVEOLI1501004
Hold-In Power Consumption In Va:
8-8 VA 50 Hz (at 20°C)
[Ue] Rated Operational Voltage:
<= 690 V AC 25...400 Hz
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Control Circuit Type:
AC 50/60 Hz
Weight:
0.58 kg
Range:
TeSys || TeSys Deca
Minimum Switching Current:
5 mA
Irms Rated Making Capacity:
140 A AC IEC 60947-5-1 || 250 A DC IEC 60947-5-1
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Environmental Disclosure:
ENVPEP1501004
Utilisation Category:
DC-13 || AC-15 || AC-14
Contactor Application:
control circuit
Non-Overlap Time:
1.5 ms on energisation between NC and NO contact || 1.5 ms on de-energisation between NC and NO contact
Control Circuit Voltage Limits:
0.3...0.6 Uc -40-70°C drop-out AC 50/60 Hz || 0.8...1.1 Uc -40-60°C operational AC 50 Hz || 0.85...1.1 Uc -40-60°C operational AC 60 Hz || 1...1.1 Uc 60-70°C operational AC 50/60 Hz
Inrush Power In Va:
70-70 VA 50 Hz (at 20°C)
Ambient Air Temperature For Operation:
-40-60°C || 60-70°C with derating
Net Weight:
0.58 kg
Protective Treatment:
TH IEC 60068
Eu Rohs Directive:
Compliant with Exemptions
$63.25

Description

TeSys D control relay, 5 contacts (3NO + 2NC), 10A/690V, for control of electromagnetic loads AC-15/DC-13. It provides a 24V 50/60Hz AC control circuit, connection by lugs. For high operating rates until 180 cycles/min and ambient temperature -40/+60°C, it procures high reliability and durability. Compact (45mm width), for clipping on 35mm DIN rail or fixing by screw. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium product (RoHS/REACh).
View AllClose