[Icw] Rated Short-Time Withstand Current:
100 A - 1 s || 120 A - 500 ms || 140 A - 100 ms
Maximum Operating Rate:
180 cyc/mn
Associated Fuse Rating:
10 A gG conforming to IEC 60947-5-1
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Sustainable Offer Status:
Green Premium product
Circularity Profile:
ENVEOLI1501004
Weight:
0.58 kg
[Uc] Control Circuit Voltage:
48 V AC 50/60 Hz
Mercury Free:
Yes
Control Circuit Type:
AC 50/60 Hz
Non-Overlap Time:
1.5 ms on energisation between NC and NO contact || 1.5 ms on de-energisation between NC and NO contact
Warranty:
18 months
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Minimum Switching Voltage:
17 V
Irms Rated Making Capacity:
140 A AC IEC 60947-5-1 || 250 A DC IEC 60947-5-1
Net Weight:
0.58 kg
Inrush Power In Va:
70-70 VA 50 Hz (at 20°C)
Range:
TeSys || TeSys Deca
Insulation Resistance:
> 10 MOhm
Hold-In Power Consumption In Va:
8-8 VA 50 Hz (at 20°C)
[Ui] Rated Insulation Voltage:
600 V UL || 600 V CSA || 690 V IEC 60947-5-1
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Connections - Terminals:
lugs-ring terminals 8 mm)
Mechanical Durability:
30 Mcycles
Standards:
EN/IEC 60947-5-1 || GB/T 14048.5 || UL 60947-5-1 || CSA C22.2 No 60947-5-1 || JIS C8201-5-1
Mounting Support:
rail || plate
Product Certifications:
CB || CCC || UL || CSA || EAC || CE || UKCA
Product Name:
TeSys CAD
[Ith] Conventional Free Air Thermal Current:
10 A (at 60°C)
Utilisation Category:
AC-15 || DC-13 || AC-14
Operating Time:
12...22 ms coil energisation and NO closing || 4...12 ms coil de-energisation and NO opening || 4...19 ms coil energisation and NC opening || 6...17 ms coil de-energisation and NC closing
Ambient Air Temperature For Storage:
-60-80°C
Product Or Component Type:
control relay
Depth:
84 mm
[Ue] Rated Operational Voltage:
<= 690 V AC 25...400 Hz
[Uimp] Rated Impulse Withstand Voltage:
6 kV IEC 60947
Minimum Switching Current:
5 mA
Control Circuit Voltage Limits:
0.3...0.6 Uc -40-70°C drop-out AC 50/60 Hz || 0.8...1.1 Uc -40-60°C operational AC 50 Hz || 0.85...1.1 Uc -40-60°C operational AC 60 Hz || 1...1.1 Uc 60-70°C operational AC 50/60 Hz
Protective Treatment:
TH IEC 60068
Device Short Name:
CAD
Rohs Exemption Information:
Yes
Operating Altitude:
0...9842.52 ft (0...3000 m)
Country of Origin:
Indonesia
Environmental Disclosure:
ENVPEP1501004
Pole Contact Composition:
3 NO + 2 NC
$63.25

Description

TeSys D control relay, 5 contacts (3NO + 2NC), 10A/690V, for control of electromagnetic loads AC-15/DC-13. It provides a 48V AC control circuit with no inrush consumption and equipped with a surge suppression device, connection by lugs. For high operating rates until 180 cycles/min and ambient temperature -40/+60°C, it procures high reliability and durability. Compact (45mm width), for clipping on 35mm DIN rail or fixing by screw. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium product (RoHS/REACh).