Schneider Electric

Schneider Electric CR1F185F7 Magnetic latching contactor,TeSys F,3P(3NO),AC-3 <=440V 185A,110V DC coil

(No reviews yet) Write a Review
SKU:
CR1F185F7
MPN:
CR1F185F7
Condition:
New
Mechanical Durability:
1 Mcycles
Product Or Component Type:
magnetic latching contactor
[Ue] Rated Operational Voltage:
1000 V AC 25...200 Hz
[Ui] Rated Insulation Voltage:
1000 V IEC 60158-1 || 1000 V IEC 60947-4 || 1000 V BS 775 || 1500 V VDE 0110 group C
Contactor Application:
resistive load || motor control
Operating Time:
35...40 ms latching || 50...100 ms unlatching
California Proposition 65:
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Ambient Air Temperature For Operation:
-15-70°C
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Range:
TeSys
Control Circuit Type:
AC 50...400 Hz || DC standard
Utilisation Category:
AC-4 || AC-1 || AC-3
Maximum Operating Rate:
120 cyc/h 40°C
Country of Origin:
Czechia
Irms Rated Making Capacity:
2100 A
Control Circuit Voltage Limits:
latching: 0.85...1.1 Uc || unlatching: 0.85...1.1 Uc
Associated Fuse Rating:
200 A aM at <= 440 V || 315 A BS88 at <= 440 V || 315 A gG at <= 440 V
Device Short Name:
CR1F
Rohs Exemption Information:
Yes
Depth:
181 mm
[Uc] Control Circuit Voltage:
110 V AC 50...400 Hz || 110 V DC
Pole Contact Composition:
3 NO
Ambient Air Temperature For Storage:
-60-80°C
Weight:
4.6 kg
Device Application:
control
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Motor Power Kw:
90 kW at 400 V AC 50/60 Hz (AC-4)
Net Weight:
4.6 kg
Mercury Free:
Yes
Warranty:
18 months
Operating Altitude:
9842.52 ft (3000 m) without derating
Product Name:
TeSys F
Pvc Free:
Yes
[Ie] Rated Operational Current:
185 A (at <40°C) at <= 440 V AC AC-3 || 275 A (at <40°C) at <= 440 V AC AC-1 || 170 A (at <40°C) at <= 440 V AC AC-4
Protective Treatment:
TC
Average Impedance:
0.36 mOhm - Ith 275 A 50 Hz
Tightening Torque:
18 N.m
Average Coil Consumption:
1750 VA AC 50...400 Hz latching || 11 VA AC 50...400 Hz unlatching || 1750 VA DC latching || 11 VA DC unlatching
Standards:
EN/IEC 60947-1 || EN/IEC 60947-4-1 || JIS C8201-4-1 || UL 60947-4-1 || CSA C22.2 No 60947-4-1
Poles Description:
3P
Product Certifications:
CB Scheme || UL || CSA || EAC || CE || UKCA
Eu Rohs Directive:
Compliant with Exemptions
Rated Breaking Capacity:
1800 A at 220...440 V || 1600 A at 500 V || 600 A at 1000 V || 1200 A at 660/690 V
Connections - Terminals:
bars 2 25 x 3 mm || lugs-ring terminals 1 150-150 mm² || connector 1 150-150 mm² || power circuit bolted connection
Power Dissipation Per Pole:
12 W AC-3 || 26 W AC-1
[Icw] Rated Short-Time Withstand Current:
1500 A 40°C - 1 s || 1500 A 40°C - 5 s || 1500 A 40°C - 10 s || 920 A 40°C - 30 s || 740 A 40°C - 1 min || 500 A 40°C - 3 min || 400 A 40°C - 10 min
Height:
174 mm
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
$1,847.00

Description

TeSys F magnetic latching contactor, 3 poles (3NO), 185A/1000V AC-3, for motor applications up to 90kW@400V. It provides a double coil 110V AC (50-400Hz) or DC for latching and unlatching, bolt terminals for bars or cables with lugs. Supply to the coils must be applied by pulsed contacts leading to energy saving and no sensibility to interferences for contactors remaining in closed state for long periods. For operating rates until 120 cycles/hour and environments until 70°C, it procures high reliability and durability. It makes installation and maintenance easy thanks to its drawer-mounted coil and a large choice of add-on blocks (instantaneous and time delay auxiliary contacts, suppressor blocks) and connection accessories (to be ordered separately). It conforms to IEC 60158-1 and IEC 60947-4, Green Premium product (RoHS/REACh).
View AllClose