Schneider Electric

Schneider Electric DPE32BL IEC contactor,Easy TeSys DPE,nonreversing,32A,3P,15HP at 480V AC,24V DC coil

(No reviews yet) Write a Review
SKU:
DPE32BL
MPN:
DPE32BL
Condition:
New
Net Weight:
0.37 kg
Connections - Terminals:
power circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end || power circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable end || power circuit: screw clamp terminals 1 1-4 mm² - cable
Irms Rated Making Capacity:
140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1 || 450 A at 440 V for power circuit conforming to IEC 60947
Overvoltage Category:
III
Product Certifications:
UL || CSA
Range:
Easy TeSys
Pole Contact Composition:
3 NO
Inrush Power In W:
2.4-2.4 W 20°C)
Product Name:
Easy TeSys DPE
Depth:
92 mm
Environmental Disclosure:
ENVPEP110230EN
Coil Technology:
without built-in suppressor module
Weight:
0.37 kg
Associated Fuse Rating:
10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 63 A gG at <= 690 V coordination type 1 for power circuit || 40 A gG at <= 690 V coordination type 2 for power circuit
Mechanical Robustness:
vibrations contactor open 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor open 10 Gn for 11 ms) || shocks contactor closed 15 Gn for 11 ms)
Contactor Application:
resistive load || motor control
Maximum Horse Power Rating:
2 hp at 115 V AC 50/60 Hz for 1 phase motors || 3 hp at 230/240 V AC 50/60 Hz for 1 phase motors || 7.5 hp at 200/208 V AC 50/60 Hz for 3 phase motors || 7.5 hp at 230/240 V AC 50/60 Hz for 3 phase motors || 15 hp at 460/480 V AC 50/60 Hz for 3 phase
Auxiliary Contact Composition:
1 NO
Standards:
CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 60947-4-1
Mounting Support:
rail || plate
Minimum Switching Voltage:
17 V for Signaling circuit
Ambient Air Temperature For Operation:
-40-60°C
Fire Resistance:
850°C IEC 60695-2-1
[Uimp] Rated Impulse Withstand Voltage:
6 kV IEC 60947
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Circularity Profile:
ENVEOLI1102030EN
Operating Altitude:
0...6561.68 ft (0...2000 m)
Ip Degree Of Protection:
IP20 front face IEC 60529
Motor Power Kw:
7.5 kW 220...230 V AC 50/60 Hz || 15 kW 380...400 V AC 50/60 Hz || 15 kW 415 V AC 50/60 Hz || 15 kW 440 V AC 50/60 Hz || 18.5 kW 500 V AC 50/60 Hz || 18.5 kW 660...690 V AC 50/60 Hz
[Ui] Rated Insulation Voltage:
power circuit 690 V IEC 60947-4-1 || power circuit 600 V CSA || power circuit 600 V UL || Signaling circuit 690 V IEC 60947-1
Mechanical Durability:
10 Mcycles
Pollution Degree:
3
Auxiliary Contacts Type:
mechanically linked 1 NO IEC 60947-5-1
Average Impedance:
2 mOhm - Ith 40 A 50 Hz for power circuit
Sustainable Offer Status:
Green Premium product
Non-Overlap Time:
1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
Poles Description:
3P
Signaling Circuit Frequency:
25...400 Hz
Country of Origin:
United States
[Ie] Rated Operational Current:
32 A (at <60°C) at <= 440 V AC AC-3 for power circuit || 40 A (at <60°C) at <= 440 V AC AC-1 for power circuit
Control Circuit Type:
DC
Toxic Heavy Metal Free:
Yes
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Control Circuit Voltage Limits:
drop-out: 0.1...0.3 Uc (at <70°C) || operational: 0.8...1.25 Uc (at <60°C) || operational: 1...1.25 Uc (at <70°C)
[Ue] Rated Operational Voltage:
power circuit <= 690 V AC 25...400 Hz || power circuit <= 300 V DC
Rated Breaking Capacity:
450 A at 440 V for power circuit conforming to IEC 60947
$73.75

Description

Easy TeSys DPE IEC contactor, 3 poles (3NO), for motor control applications up to 32A/690V AC-3 (15 HP@480V). It provides a 24V DC coil, 1NO+1NC built-in auxiliary contacts (NC mirror certified), connection by screw clamp terminals. Multi standards certified (IEC, UL, CSA), Green Premium compliant (RoHS/REACh).
View AllClose