Schneider Electric DPE65G7 IEC contactor,Easy TeSys DPE,nonreversing,65A,3P,40HP at 480V AC,120V AC 50/60Hz coil
Schneider Electric
$105.00
Easy TeSys DPE IEC contactor, 3 poles (3NO), for motor control applications up to 65A/690V AC-3 (40HP@480V). It provides a 120 VAC coil, 1NO built-in auxiliary contacts, connection by screw clamp terminals. Compact (55mm width), DIN-rail mounting or screw fixing. Multi standards certified (IEC, UL, CSA), Green Premium compliant (RoHS/REACh).
- Range:
- Easy TeSys
- Mercury Free:
- Yes
- Climatic Withstand:
- IACS E10 || IEC 60947-1 Annex Q category D
- Rated Breaking Capacity:
- 800 A at 440 V for power circuit conforming to IEC 60947
- Depth:
- 122 mm
- Electrical Durability:
- 0.6 Mcycles 60 A AC-1 <= 440 V || 1 Mcycles 40 A AC-3 <= 440 V
- Ip Degree Of Protection:
- IP20 front face IEC 60529
- Reach Regulation:
- Free of Substances of Very High Concern above the threshold
- Maximum Horse Power Rating:
- 3 hp at 115 V AC 50/60 Hz for 1 phase motors || 7.5 hp at 230/240 V AC 50/60 Hz for 1 phase motors || 15 hp at 200/208 V AC 50/60 Hz for 3 phase motors || 15 hp at 230/240 V AC 50/60 Hz for 3 phase motors || 40 hp at 460/480 V AC 50/60 Hz for 3 phase
- Ambient Air Temperature For Storage:
- -60-80°C
- Average Impedance:
- 1.5 mOhm - Ith 80 A 50 Hz for power circuit
- Poles Description:
- 3P
- Device Short Name:
- DPE
- Product Name:
- Easy TeSys DPE
- Reach Free Of Svhc:
- Yes
- Maximum Operating Rate:
- 3600 cyc/h 60°C
- Motor Power Kw:
- 18.5 kW 220...230 V AC 50/60 Hz || 30 kW 380...400 V AC 50/60 Hz || 37 kW 500 V AC 50/60 Hz || 37 kW 660...690 V AC 50/60 Hz
- Tightening Torque:
- power circuit 7 N.m screw connectors 16-25 mm² hexagonal 4 mm || power circuit 5 N.m screw connectors 2.5-16 mm² hexagonal 4 mm || control circuit 1.7 N.m screw clamp terminals pozidriv No 2 || control circuit 1.7 N.m screw clamp terminals flat Ã
- Signaling Circuit Frequency:
- 25...400 Hz
- Sustainable Offer Status:
- Green Premium product
- Eu Rohs Directive:
- Compliant
- Irms Rated Making Capacity:
- 140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1 || 800 A at 440 V for power circuit conforming to IEC 60947
- [Ui] Rated Insulation Voltage:
- power circuit 690 V IEC 60947-4-1 || power circuit 600 V cUL || Signaling circuit 690 V IEC 60947-1 || Signaling circuit 600 V cUL
- Utilisation Category:
- AC-1 || AC-3
- [Ie] Rated Operational Current:
- 80 A (at <60°C) at <= 440 V AC AC-1 for power circuit || 65 A (at <60°C) at <= 440 V AC AC-3 for power circuit
- Control Circuit Voltage Limits:
- drop-out: 0.3...0.6 Uc at 60 Hz (at <70°C) || operational: 0.85...1.1 Uc at 60 Hz (at <60°C) || operational: 1...1.1 Uc at 60 Hz (at <70°C)
- [Uc] Control Circuit Voltage:
- 120 V AC 60 Hz
- Hold-In Power Consumption In Va:
- 13-13 VA 60 Hz cos phi 0.3 (at 20°C)
- Mechanical Robustness:
- vibrations contactor open 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor open 10 Gn for 11 ms) || shocks contactor closed 15 Gn for 11 ms)
- Pollution Degree:
- 3
- Power Dissipation Per Pole:
- 9.6 W AC-1 || 6.3 W AC-3
- Rohs Exemption Information:
- Yes
- China Rohs Regulation:
- Pro-active China RoHS declaration (out of China RoHS legal scope)
- Overvoltage Category:
- III
- Auxiliary Contacts Type:
- mechanically linked 1 NO IEC 60947-5-1
- Minimum Switching Voltage:
- 17 V for Signaling circuit
- Operating Time:
- 4...19 ms opening || 12...26 ms closing
- Product Or Component Type:
- contactor
- Circularity Profile:
- ENVEOLI1503009EN
- Associated Fuse Rating:
- 10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 125 A gG at <= 690 V coordination type 1 for power circuit || 125 A gG at <= 690 V coordination type 2 for power circuit
- Mounting Support:
- rail || plate
- Safety Reliability Level:
- B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
- Mechanical Durability:
- 5 Mcycles
- [Ue] Rated Operational Voltage:
- power circuit <= 690 V AC 25...400 Hz || power circuit <= 300 V DC
- Minimum Switching Current:
- 5 mA for Signaling circuit