Easy TeSys DPE IEC contactor, 3 poles (3NO), for motor control applications up to 65A/690V AC-3 (40HP@480V). It provides a 240 VAC coil, 1NO built-in auxiliary contacts, connection by screw clamp terminals. Compact (55mm width), DIN-rail mounting or screw fixing. Multi standards certified (IEC, UL, CSA), Green Premium compliant (RoHS/REACh).
- Inrush Power In Va:
- 140-140 VA 60 Hz cos phi 0.75 (at 20°C)
- Reach Free Of Svhc:
- Yes
- Motor Power Kw:
- 18.5 kW 220...230 V AC 50/60 Hz || 30 kW 380...400 V AC 50/60 Hz || 37 kW 500 V AC 50/60 Hz || 37 kW 660...690 V AC 50/60 Hz
- Insulation Resistance:
- > 10 MOhm for Signaling circuit
- Product Or Component Type:
- contactor
- Minimum Switching Voltage:
- 17 V for Signaling circuit
- Safety Reliability Level:
- B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
- Auxiliary Contacts Type:
- mechanically linked 1 NO IEC 60947-5-1
- Hold-In Power Consumption In Va:
- 13-13 VA 60 Hz cos phi 0.3 (at 20°C)
- Heat Dissipation:
- 4-5 W 50/60 Hz
- Mercury Free:
- Yes
- Pole Contact Composition:
- 3 NO
- Operating Altitude:
- 0...6561.68 ft (0...2000 m)
- Height:
- 122 mm
- [Uimp] Rated Impulse Withstand Voltage:
- 6 kV IEC 60947
- Pollution Degree:
- 3
- Ambient Air Temperature For Storage:
- -60-80°C
- Mechanical Robustness:
- vibrations contactor open 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor open 10 Gn for 11 ms) || shocks contactor closed 15 Gn for 11 ms)
- Maximum Horse Power Rating:
- 3 hp at 115 V AC 50/60 Hz for 1 phase motors || 7.5 hp at 230/240 V AC 50/60 Hz for 1 phase motors || 15 hp at 200/208 V AC 50/60 Hz for 3 phase motors || 15 hp at 230/240 V AC 50/60 Hz for 3 phase motors || 40 hp at 460/480 V AC 50/60 Hz for 3 phase
- Maximum Operating Rate:
- 3600 cyc/h 60°C
- Standards:
- CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 60947-4-1
- China Rohs Regulation:
- Pro-active China RoHS declaration (out of China RoHS legal scope)
- [Ith] Conventional Free Air Thermal Current:
- 10 A (at 60°C) for Signaling circuit || 60 A (at 60°C) for power circuit
- Circularity Profile:
- ENVEOLI1503009EN
- Product Certifications:
- cULus
- Connections - Terminals:
- power circuit: screw connection 1 2.5-25 mm² - cable stiffness: flexible without cable end || power circuit: screw connection 2 2.5-16 mm² - cable stiffness: flexible without cable end || power circuit: screw connection 1 2.5-25 mm² - cable stiffn
- Tightening Torque:
- power circuit 7 N.m screw connectors 16-25 mm² hexagonal 4 mm || power circuit 5 N.m screw connectors 2.5-16 mm² hexagonal 4 mm || control circuit 1.7 N.m screw clamp terminals pozidriv No 2 || control circuit 1.7 N.m screw clamp terminals flat Ã
- Depth:
- 122 mm
- Poles Description:
- 3P
- Eu Rohs Directive:
- Compliant
- Device Short Name:
- DPE
- Signaling Circuit Frequency:
- 25...400 Hz
- Ip Degree Of Protection:
- IP20 front face IEC 60529
- Product Name:
- Easy TeSys DPE
- Power Dissipation Per Pole:
- 9.6 W AC-1 || 6.3 W AC-3
- [Uc] Control Circuit Voltage:
- 240 V AC 50/60 Hz
- Control Circuit Voltage Limits:
- drop-out: 0.3...0.6 Uc at 50/60 Hz (at <70°C) || operational: 0.8...1.1 Uc at 50 Hz (at <60°C) || operational: 0.85...1.1 Uc at 60 Hz (at <60°C) || operational: 1...1.1 Uc at 50/60 Hz (at <70°C)
- Minimum Switching Current:
- 5 mA for Signaling circuit
- Electrical Durability:
- 0.6 Mcycles 60 A AC-1 <= 440 V || 1 Mcycles 40 A AC-3 <= 440 V
- Contactor Application:
- motor control || resistive load
- Environmental Disclosure:
- ENVPEP1503009EN
- Operating Time:
- 4...19 ms opening || 12...26 ms closing
- Coil Technology:
- without built-in suppressor module
- [Ie] Rated Operational Current:
- 80 A (at <60°C) at <= 440 V AC AC-1 for power circuit || 65 A (at <60°C) at <= 440 V AC AC-3 for power circuit
- Average Impedance:
- 1.5 mOhm - Ith 80 A 50 Hz for power circuit
- Mechanical Durability:
- 5 Mcycles
- [Icw] Rated Short-Time Withstand Current:
- 520 A 40°C - 10 s for power circuit || 900 A 40°C - 1 s for power circuit || 110 A 40°C - 10 min for power circuit || 260 A 40°C - 1 min for power circuit || 100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 ms