Schneider Electric

Schneider Electric DPER03 Thermal overload relay,Easy TeSys DPER,0.25-0.40A,class 10

(No reviews yet) Write a Review
SKU:
DPER03
MPN:
DPER03
Condition:
New
Device Short Name:
DPER
Ip Degree Of Protection:
IP20 conforming to IEC 60529
Thermal Overload Class:
class 10 IEC 60947-4-1
Product Name:
Easy TeSys DPER
Temperature Compensation:
-20-60°C
Tightening Torque:
control circuit 1.7 N.m screw clamp terminals || power circuit 1.7 N.m screw clamp terminals
Rohs Exemption Information:
Yes
[Ui] Rated Insulation Voltage:
power circuit 600 V cUL || power circuit 690 V IEC 60947-4-1
Control Type:
Red push-button stop || Blue push-button reset
Eu Rohs Directive:
Compliant
Toxic Heavy Metal Free:
Yes
Phase Failure Sensitivity:
tripping current 130 % of Ir on two phase, the last one at 0
Thermal Protection Adjustment Range:
0.25-0.40 A
Surge Withstand:
6 kV IEC 60801-5
Network Frequency:
0...400 Hz
Sustainable Offer Status:
Green Premium product
Permissible Current:
3 A 120 V AC-15 Signaling circuit || 0.22 A 125 V DC-13 Signaling circuit
Relay Application:
overload protection
Circularity Profile:
ENVEOLI0802006
Net Weight:
0.124 kg
Auxiliary Contact Composition:
1 NO + 1 NC
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Country of Origin:
France
Mounting Support:
separate, with specific accessories || under contactor
Vibration Resistance:
6 gn on plate IEC 60068-2-6
Shock Resistance:
15 gn 11 ms IEC 60068-2-7
[Uimp] Rated Impulse Withstand Voltage:
6 kV
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
California Proposition 65:
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Standards:
EN/IEC 60947-4-1 || EN/IEC 60947-5-1 || UL 60947-4-1 || UL 60947-5-1 || cUL
Dielectric Strength:
1.89 kV 50 Hz IEC 60947-1
Mercury Free:
Yes
Depth:
70 mm
Product Compatibility:
contactor DPE09-38
Ambient Air Temperature For Storage:
-60-70°C
Ambient Air Temperature For Operation:
-20-60°C without derating IEC 60947-4-1
Range:
Easy TeSys
Network Type:
DC || AC
Connections - Terminals:
control circuit screw clamp terminals 2 1-2.5 mm² flexible without cable end || control circuit screw clamp terminals 2 1-2.5 mm² flexible with cable end || control circuit screw clamp terminals 2 1-2.5 mm² solid without cable end || power circuit
Protection Type:
BS fuse 5 A - control circuit || GB2 circuit breaker 5 A - control circuit || gG fuse 5 A - control circuit
Protective Treatment:
TH IEC 60068
Product Certifications:
cUL
Product Or Component Type:
thermal overload relay
Weight:
0.124 kg
Tripping Threshold:
1.14 +/- 0.06 Ir IEC 60947-4-1
Environmental Disclosure:
ENVPEP080206EN
$28.75

Description

Easy TeSys DPER thermal overload relay, 0.4A/690V, thermal setting range 0.25-0.4A, tripping class 10, for protection of 3-phase motors 0.09kW@400V. Differential device with phase failure and load unbalance detection. It provides a thermal adjustement dial, a manual-automatic reset selector, a test selector for simulation of a tripping, reset and stop buttons, a flag indicator and 2 auxiliary contacts 1NO+1NC for fault signalling. Settings are protected by a transparent cover lockable by sealing. Connection by screw clamp terminals, it connects directly to the bottom terminals of 3-pole contactors DPE09-D38. Mounting on DIN rail or screw fixing, separated from the contactor. Multi standards certified (IEC, cUL), Green Premium compliant (RoHs/Reach).
View AllClose