Schneider Electric

Schneider Electric DPER04 Thermal overload relay,Easy TeSys DPER,0.40-0.63A,class 10

(No reviews yet) Write a Review
SKU:
DPER04
MPN:
DPER04
Condition:
New
[Ith] Conventional Free Air Thermal Current:
5 A Signaling circuit
Mercury Free:
Yes
Circularity Profile:
ENVEOLI0802006
Connections - Terminals:
control circuit screw clamp terminals 2 1-2.5 mm² flexible without cable end || control circuit screw clamp terminals 2 1-2.5 mm² flexible with cable end || control circuit screw clamp terminals 2 1-2.5 mm² solid without cable end || power circuit
Control Type:
Red push-button stop || Blue push-button reset
Mounting Support:
separate, with specific accessories || under contactor
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Network Frequency:
0...400 Hz
Protection Type:
BS fuse 5 A - control circuit || GB2 circuit breaker 5 A - control circuit || gG fuse 5 A - control circuit
Vibration Resistance:
6 gn on plate IEC 60068-2-6
Thermal Protection Adjustment Range:
0.40-0.63 A
Environmental Disclosure:
ENVPEP080206EN
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Product Compatibility:
contactor DPE09-38
Dielectric Strength:
1.89 kV 50 Hz IEC 60947-1
[Ui] Rated Insulation Voltage:
power circuit 600 V cUL || power circuit 690 V IEC 60947-4-1
Tripping Threshold:
1.14 +/- 0.06 Ir IEC 60947-4-1
Shock Resistance:
15 gn 11 ms IEC 60068-2-7
Phase Failure Sensitivity:
tripping current 130 % of Ir on two phase, the last one at 0
California Proposition 65:
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
[Uimp] Rated Impulse Withstand Voltage:
6 kV
Toxic Heavy Metal Free:
Yes
Weight:
0.124 kg
[Ue] Rated Operational Voltage:
690 V AC 0...400 Hz power circuit IEC 60947-4-1
Tightening Torque:
control circuit 1.7 N.m screw clamp terminals || power circuit 1.7 N.m screw clamp terminals
Range:
Easy TeSys
Product Certifications:
cUL
Permissible Current:
3 A 120 V AC-15 Signaling circuit || 0.22 A 125 V DC-13 Signaling circuit
Rohs Exemption Information:
Yes
Sustainable Offer Status:
Green Premium product
Ambient Air Temperature For Storage:
-60-70°C
Net Weight:
0.124 kg
Country of Origin:
France
Network Type:
DC || AC
Eu Rohs Directive:
Compliant
Surge Withstand:
6 kV IEC 60801-5
Standards:
EN/IEC 60947-4-1 || EN/IEC 60947-5-1 || UL 60947-4-1 || UL 60947-5-1 || cUL
Relay Application:
overload protection
Device Short Name:
DPER
Temperature Compensation:
-20-60°C
Protective Treatment:
TH IEC 60068
Ambient Air Temperature For Operation:
-20-60°C without derating IEC 60947-4-1
Depth:
70 mm
Product Or Component Type:
thermal overload relay
Auxiliary Contact Composition:
1 NO + 1 NC
Thermal Overload Class:
class 10 IEC 60947-4-1
$28.75

Description

Easy TeSys DPER thermal overload relay, 0.63A/690V, thermal setting range 0.4-0.63A, tripping class 10, for protection of 3-phase motors 0.12-0.18kW@400V. Differential device with phase failure and load unbalance detection. It provides a thermal adjustement dial, a manual-automatic reset selector, a test selector for simulation of a tripping, reset and stop buttons, a flag indicator and 2 auxiliary contacts 1NO+1NC for fault signalling. Settings are protected by a transparent cover lockable by sealing. Connection by screw clamp terminals, it connects directly to the bottom terminals of 3-pole contactors DPE09-D38. Mounting on DIN rail or screw fixing, separated from the contactor. Multi standards certified (IEC, cUL), Green Premium compliant (RoHs/Reach).
View AllClose