Schneider Electric

Schneider Electric DPER16 Thermal overload relay,Easy TeSys DPER,9-13A,class 10

(No reviews yet) Write a Review
SKU:
DPER16
MPN:
DPER16
Condition:
New
Mercury Free:
Yes
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Tightening Torque:
control circuit 1.7 N.m screw clamp terminals || power circuit 1.7 N.m screw clamp terminals
Mounting Support:
separate, with specific accessories || under contactor
Vibration Resistance:
6 gn on plate IEC 60068-2-6
Thermal Protection Adjustment Range:
9-13 A
Eu Rohs Directive:
Compliant
Environmental Disclosure:
ENVPEP080206EN
Toxic Heavy Metal Free:
Yes
Depth:
70 mm
California Proposition 65:
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Permissible Current:
1.5 A 240 V AC-15 Signaling circuit || 0.1 A 250 V DC-13 Signaling circuit
Rohs Exemption Information:
Yes
Shock Resistance:
15 gn 11 ms IEC 60068-2-7
[Ith] Conventional Free Air Thermal Current:
5 A Signaling circuit
Protection Type:
BS fuse 5 A - control circuit || GB2 circuit breaker 5 A - control circuit || gG fuse 5 A - control circuit
Dielectric Strength:
1.89 kV 50 Hz IEC 60947-1
Relay Application:
overload protection
Ip Degree Of Protection:
IP20 conforming to IEC 60529
Auxiliary Contact Composition:
1 NO + 1 NC
Thermal Overload Class:
class 10 IEC 60947-4-1
Protective Treatment:
TH IEC 60068
Range:
Easy TeSys
Product Name:
Easy TeSys DPER
Tripping Threshold:
1.14 +/- 0.06 Ir IEC 60947-4-1
Circularity Profile:
ENVEOLI0802006
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Sustainable Offer Status:
Green Premium product
Product Or Component Type:
thermal overload relay
Phase Failure Sensitivity:
tripping current 130 % of Ir on two phase, the last one at 0
Ambient Air Temperature For Operation:
-20-60°C without derating IEC 60947-4-1
Device Short Name:
DPER
Connections - Terminals:
control circuit screw clamp terminals 2 1-2.5 mm² flexible without cable end || control circuit screw clamp terminals 2 1-2.5 mm² flexible with cable end || control circuit screw clamp terminals 2 1-2.5 mm² solid without cable end || power circuit
Temperature Compensation:
-20-60°C
Network Frequency:
0...400 Hz
[Uimp] Rated Impulse Withstand Voltage:
6 kV
Weight:
0.124 kg
Surge Withstand:
6 kV IEC 60801-5
Control Type:
Red push-button stop || Blue push-button reset
Product Certifications:
cUL
Country of Origin:
France
Product Compatibility:
contactor DPE09-38
Ambient Air Temperature For Storage:
-60-70°C
Standards:
EN/IEC 60947-4-1 || EN/IEC 60947-5-1 || UL 60947-4-1 || UL 60947-5-1 || cUL
Network Type:
DC || AC
[Ue] Rated Operational Voltage:
690 V AC 0...400 Hz power circuit IEC 60947-4-1
$28.75

Description

Easy TeSys DPER thermal overload relay, 13A/690V, thermal setting range 9-13A, tripping class 10, for protection of 3-phase motors 5.5kW@400V. Differential device with phase failure and load unbalance detection. It provides a thermal adjustement dial, a manual-automatic reset selector, a test selector for simulation of a tripping, reset and stop buttons, a flag indicator and 2 auxiliary contacts 1NO+1NC for fault signalling. Settings are protected by a transparent cover lockable by sealing. Connection by screw clamp terminals, it connects directly to the bottom terminals of 3-pole contactors DPE09-D38. Mounting on DIN rail or screw fixing, separated from the contactor. Multi standards certified (IEC, cUL), Green Premium compliant (RoHs/Reach).