- Ip Degree Of Protection:
- IP20 conforming to IEC 60529
- Product Or Component Type:
- differential thermal overload relay
- Protective Treatment:
- TH IEC 60068
- Tripping Threshold:
- 1.14 +/- 0.06 Ir IEC 60947-4-1
- Thermal Overload Class:
- class 10 IEC 60947-4-1
- Shock Resistance:
- 15 gn 11 ms IEC 60068-2-7
- Sustainable Offer Status:
- Green Premium product
- Country of Origin:
- France
- Ambient Air Temperature For Storage:
- -60-70°C
- Permissible Current:
- 0.95 A 240 V AC-15 Signaling circuit || 0.06 A 250 V DC-13 Signaling circuit
- Product Certifications:
- IEC || cULus
- [Ue] Rated Operational Voltage:
- 300 V AC 0...400 Hz power circuit IEC 60947-4-1
- Environmental Disclosure:
- ENVPEP080405EN
- [Uimp] Rated Impulse Withstand Voltage:
- 6 kV
- Control Type:
- Red push-button stop || Blue push-button reset
- Product Compatibility:
- contactor DPE40-65
- Dielectric Strength:
- 1.89 kV 50 Hz IEC 60947-1
- Rohs Exemption Information:
- Yes
- China Rohs Regulation:
- Pro-active China RoHS declaration (out of China RoHS legal scope)
- Temperature Compensation:
- -20-60°C
- Network Type:
- DC || AC
- Surge Withstand:
- 6 kV IEC 60801-5
- Product Name:
- Easy TeSys DPER
- Relay Application:
- motor protection
- Device Short Name:
- DPER
- Weight:
- 0.375 kg
- Connections - Terminals:
- control circuit screw clamp terminals 2 1-2.5 mm² flexible without cable end || control circuit screw clamp terminals 2 1-2.5 mm² flexible with cable end || control circuit screw clamp terminals 2 1-2.5 mm² solid without cable end || power circuit
- Vibration Resistance:
- 4 gn on plate IEC 60068-2-6
- Circularity Profile:
- ENVEOLI0804005_V1
- Eu Rohs Directive:
- Compliant
- Standards:
- EN/IEC 60947-4-1 || EN/IEC 60947-5-1 || UL 60947-4-1 || UL 60947-5-1 || CSA C22.2 No 60947-4-1 || CSA C22.2 No 60947-5-1 || EN 50495
- Tightening Torque:
- control circuit 1.7 N.m screw clamp terminals || power circuit 5 N.m screw connection 2.5-16 mm² || power circuit 7 N.m screw connection 16-25 mm²
- Network Frequency:
- 0...400 Hz
- Flame Retardance:
- V1 conforming to UL 94
- Protection Type:
- BS fuse 4 A - Signaling circuit || gG fuse 4 A - Signaling circuit
- Net Weight:
- 0.375 kg
- [Ui] Rated Insulation Voltage:
- power circuit 600 V UL 60947-4-1 || power circuit 690 V IEC 60947-4-1
- Ambient Air Temperature For Operation:
- -20-60°C without derating IEC 60947-4-1
- Auxiliary Contact Composition:
- 1 NO + 1 NC
- Reach Free Of Svhc:
- Yes
- Range:
- Easy TeSys
- Mounting Support:
- plate, with specific accessories || rail, with specific accessories || under contactor
- Mercury Free:
- Yes
- [Ith] Conventional Free Air Thermal Current:
- 5 A Signaling circuit
- Depth: