Schneider Electric

Schneider Electric EDB14030CA Mini circuit breaker, E-Frame, 30A, 1 pole, 277VAC, 25kA max, bolt on, 50 degrees C

(No reviews yet) Write a Review
SKU:
EDB14030CA
MPN:
EDB14030CA
Condition:
New
Ambient Air Temperature For Operation:
50°C
Module Type:
E-Frame
Breaking Capacity:
18 kA 277 V AC || 18 kA 240 V AC || 25 kA 120 V AC || 18 kA 120/240 V AC
Number Of Poles:
1
Holding Current:
270 A
Number Of Spaces:
1
Local Signaling:
trip indicator
[Ue] Rated Operational Voltage:
277 V AC
Country of Origin:
Ireland
Line Rated Current:
30 A
Weight:
2 lb(US)
Protection Type:
overload || short-circuit
Trip Unit Technology:
thermal-magnetic
Device Short Name:
EDB
Product Destination:
NF panelboard
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
Product Certifications:
cULus
Range Of Product:
125 A Frame EDB-EGB-EJB
Electrical Connection:
lugs aluminium
Mounting Mode:
bolt-on
Net Weight:
2 lb(US)
Rohs Exemption Information:
Yes
Tightening Torque:
3.4-3.4 N.m 2.5-16 mm² (AWG 14...AWG 6)
Breaking Capacity Code:
D
Number Of Spaces Required:
1
Mercury Free:
Yes
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Awg Gauge:
AWG 12...AWG 6 aluminium || AWG 14...AWG 6 copper
Product Or Component Type:
miniature circuit-breaker
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Trip Unit Rating:
875-875 A
Circuit Breaker Application:
HACR rated
Depth:
4.05 in
$180.00

Description

E-Frame Breaker are Lighting Panelboard Circuit breakers that are proven effective and reliable which provide a wide variety or robust features that are use specifically in Square D NF Panelboards. This range of breaker is ideally designed to offer superior overload and short circuit protection. All E-Frame breakers have a thermal-magnetic trip unit as well as signal indicator that will indicate when a trip has occur. Mounting bolts are used to hold these breakers in place. This E-Frame breaker is 30A, 1 pole, and has an operating voltage of 277 VAC. It also provides a 25 kA max interrupt rating at 120 VAC. This device has a hold current of 270A which is the maximum current the breaker can be held to ensure it will trip and a trip current of 875A which is the current value when the breaker is guaranteed to trip. Many accessories are available for this breaker. This breaker was calibrated for 50 degrees C. This product is UL Listed as High Intensity Discharge. HACR rated.
View AllClose