Schneider Electric

Schneider Electric EDB34020SACA Mini circuit breaker, E-Frame, 20A, 3 pole, 480Y/277VAC, 25kA max, bolt on, shunt trip, 50 degrees C

(No reviews yet) Write a Review
SKU:
EDB34020SACA
MPN:
EDB34020SACA
Condition:
New
Mounting Mode:
bolt-on
Trip Unit Technology:
thermal-magnetic
[Ue] Rated Operational Voltage:
480Y/277 V AC
Product Or Component Type:
miniature circuit-breaker
Ambient Air Temperature For Operation:
50°C
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
Number Of Spaces:
4
Breaking Capacity Code:
D
Country of Origin:
Mexico
Device Composition:
shunt trip
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Warranty:
18 months
Local Signaling:
trip indicator
Tightening Torque:
3.4-3.4 N.m 2.5-16 mm² (AWG 14...AWG 6)
Number Of Spaces Required:
4
Holding Current:
270 A
Mercury Free:
Yes
Product Certifications:
cULus
Weight:
4 lb(US)
Product Destination:
NF panelboard
Device Short Name:
EDB
Protection Type:
overload || short-circuit
Breaking Capacity:
18 kA 277 V AC || 25 kA 240 V AC || 18 kA 480Y/277 V AC || 25 kA 120 V AC || 25 kA 120/240 V AC
Trip Unit Rating:
875-875 A
Awg Gauge:
AWG 12...AWG 6 aluminium || AWG 14...AWG 6 copper
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Rohs Exemption Information:
Yes
Net Weight:
4 lb(US)
Line Rated Current:
20 A
Circuit Breaker Application:
HACR rated || HID rated
Depth:
4.05 in
Number Of Poles:
3
Electrical Connection:
lugs aluminium
Range Of Product:
125 A Frame EDB-EGB-EJB
Module Type:
E-Frame
$1,558.00

Description

E-Frame Breaker are Lighting Panelboard Circuit breakers that are proven effective and reliable which provide a wide variety or robust features that are use specifically in Square D NF Panelboards. This range of breaker is ideally designed to offer superior overload and short circuit protection. All E-Frame breakers have a thermal-magnetic trip unit as well as signal indicator that will indicate when a trip has occur. Mounting bolts are used to hold these breakers in place. This E-Frame breaker is 20A, 3 pole, and has an operating voltage of 480Y/277 VAC. It also provides a 25 kA max interrupt rating at 120 VAC. This device has a hold current of 270A which is the maximum current the breaker can be held to ensure it will trip and a trip current of 875A which is the current value when the breaker is guaranteed to trip. Many accessories are available for this breaker. This one includes a shunt trip. This breaker was calibrated for 50 degrees C. This product is UL Listed as High Intensity Discharge. HACR rated.
View AllClose