Schneider Electric

Schneider Electric EDB34100AABA Mini circuit breaker, E-Frame, 100A, 3 pole, 480Y/277VAC, 25kA max, bolt on, aux switch, alarm switch

(No reviews yet) Write a Review
SKU:
EDB34100AABA
MPN:
EDB34100AABA
Condition:
New
Eu Rohs Directive:
Compliant with Exemptions
Product Destination:
NF panelboard
Electrical Connection:
lugs aluminium
Range Of Product:
125 A Frame EDB-EGB-EJB
Weight:
4 lb(US)
Ambient Air Temperature For Operation:
40°C
Net Weight:
4 lb(US)
Tightening Torque:
3.9-3.9 N.m 2.5-6 mm² (AWG 14...AWG 10) || 5.6-5.6 N.m 10-70 mm² (AWG 8...AWG 2/0)
Awg Gauge:
AWG 12...AWG 2/0 aluminium || AWG 14...AWG 2/0 copper
Trip Unit Technology:
thermal-magnetic
Module Type:
E-Frame
Breaking Capacity Code:
D
Device Composition:
auxiliary switch || alarm switch
[Ue] Rated Operational Voltage:
480Y/277 V AC
Local Signaling:
trip indicator
Depth:
4.05 in
Mercury Free:
Yes
Breaking Capacity:
18 kA 277 V AC || 25 kA 240 V AC || 18 kA 480Y/277 V AC || 25 kA 120 V AC || 25 kA 120/240 V AC
Country of Origin:
Mexico
Number Of Poles:
3
Trip Unit Rating:
2300-2300 A
Product Or Component Type:
miniature circuit-breaker
Protection Type:
short-circuit || overload
Product Certifications:
cULus
Holding Current:
1000 A
Line Rated Current:
100 A
Circuit Breaker Application:
HACR rated
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Rohs Exemption Information:
Yes
Device Short Name:
EDB
Number Of Spaces:
4
Mounting Mode:
bolt-on
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Number Of Spaces Required:
4
$1,223.00

Description

E-Frame Breaker are Lighting Panelboard Circuit breakers that are proven effective and reliable which provide a wide variety or robust features that are use specifically in Square D NF Panelboards. This range of breaker is ideally designed to offer superior overload and short circuit protection. All E-Frame breakers have a thermal-magnetic trip unit as well as signal indicator that will indicate when a trip has occur. Mounting bolts are used to hold these breakers in place. This E-Frame breaker is 100A, 3 pole, and has an operating voltage of 480Y/277 VAC. It also provides a 25 kA max interrupt rating at 120 VAC. This device has a hold current of 1000A which is the maximum current the breaker can be held to ensure it will trip and a trip current of 2300A which is the current value when the breaker is guaranteed to trip. Many accessories are available for this breaker. This one includes an auxiliary switch and an alarm switch. This breaker was calibrated for 40 degrees C. HACR rated.
View AllClose