Breaking Capacity:
18 kA 277 V AC || 25 kA 240 V AC || 18 kA 480Y/277 V AC || 25 kA 120 V AC || 25 kA 120/240 V AC
Depth:
4.05 in
Protection Type:
short-circuit || overload
Electrical Connection:
lugs aluminium
Net Weight:
4 lb(US)
Rohs Exemption Information:
Yes
Warranty:
18 months
Trip Unit Rating:
2300-2300 A
Number Of Poles:
3
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Mounting Mode:
bolt-on
Mercury Free:
Yes
Tightening Torque:
3.9-3.9 N.m 2.5-6 mm² (AWG 14...AWG 10) || 5.6-5.6 N.m 10-70 mm² (AWG 8...AWG 2/0)
Circuit Breaker Application:
HACR rated
Local Signaling:
trip indicator
Number Of Spaces:
3
Country of Origin:
United States
Module Type:
E-Frame
Weight:
4 lb(US)
Range Of Product:
125 A Frame EDB-EGB-EJB
Breaking Capacity Code:
D
Number Of Spaces Required:
3
Awg Gauge:
AWG 12...AWG 2/0 aluminium || AWG 14...AWG 2/0 copper
Product Or Component Type:
miniature circuit-breaker
Product Certifications:
cULus
Device Short Name:
EDB
[Ue] Rated Operational Voltage:
480Y/277 V AC
Product Destination:
NF panelboard
Ambient Air Temperature For Operation:
50°C
Trip Unit Technology:
thermal-magnetic
Line Rated Current:
100 A
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Holding Current:
1000 A
$1,093.00

Description

E-Frame Breaker are Lighting Panelboard Circuit breakers that are proven effective and reliable which provide a wide variety or robust features that are use specifically in Square D NF Panelboards. This range of breaker is ideally designed to offer superior overload and short circuit protection. All E-Frame breakers have a thermal-magnetic trip unit as well as signal indicator that will indicate when a trip has occur. Mounting bolts are used to hold these breakers in place. This E-Frame breaker is 100A, 3 pole, and has an operating voltage of 480Y/277 VAC. It also provides a 25 kA max interrupt rating at 120 VAC. This device has a hold current of 1000A which is the maximum current the breaker can be held to ensure it will trip and a trip current of 2300A which is the current value when the breaker is guaranteed to trip. Many accessories are available for this breaker. This breaker was calibrated for 50 degrees C. HACR rated.