Schneider Electric

Schneider Electric EGB14015EPD Mini circuit breaker, E-Frame, 15A, 1 pole, 277VAC, 65kA max, bolt on, 30mA ground fault protection

(No reviews yet) Write a Review
SKU:
EGB14015EPD
MPN:
EGB14015EPD
Condition:
New
Breaking Capacity:
35 kA 277 V AC || 35 kA 240 V AC || 65 kA 120 V AC || 35 kA 120/240 V AC
Net Weight:
2 lb(US)
Ambient Air Temperature For Operation:
40°C
Number Of Poles:
1
Range Of Product:
125 A Frame EDB-EGB-EJB
Product Certifications:
cULus
Electrical Connection:
lugs aluminium
Weight:
2 lb(US)
Awg Gauge:
AWG 14...AWG 6 copper || AWG 12...AWG 4 aluminium
Tightening Torque:
3.4-3.4 N.m 2.5-16 mm² (AWG 14...AWG 6)
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Mercury Free:
Yes
Depth:
4.05 in
Trip Unit Rating:
875-875 A
Module Type:
E-Frame
Device Short Name:
EGB
Circuit Breaker Application:
HACR rated || Switching Duty rated || HID rated
Earth-Leakage Sensitivity:
30 mA
Warranty:
18 months
Breaking Capacity Code:
G
Protection Type:
overload || short-circuit
Local Signaling:
trip indicator
Holding Current:
270 A
Number Of Spaces:
2
Product Destination:
NF panelboard
Rohs Exemption Information:
Yes
[Ue] Rated Operational Voltage:
277 V AC
Product Or Component Type:
miniature circuit-breaker
Number Of Spaces Required:
2
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Earth-Leakage Protection Class:
class B
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
Line Rated Current:
15 A
Mounting Mode:
bolt-on
Country of Origin:
United States
Trip Unit Technology:
thermal-magnetic
$1,256.00

Description

E-Frame Breaker are Lighting Panelboard Circuit breakers that are proven effective and reliable which provide a wide variety or robust features that are use specifically in Square D NF Panelboards. This range of breaker is ideally designed to offer superior overload and short circuit protection. All E-Frame breakers have a thermal-magnetic trip unit as well as signal indicator that will indicate when a trip has occur. Mounting bolts are used to hold these breakers in place. This E-Frame breaker is 15A, 1 pole, and has an operating voltage of 277 VAC. It also provides a 65 kA max interrupt rating at 120 VAC. This device has a hold current of 270A which is the maximum current the breaker can be held to ensure it will trip and a trip current of 875A which is the current value when the breaker is guaranteed to trip. Many accessories are available for this breaker. This one includes 30 mA ground protection. This breaker was calibrated for 40 degrees C. This product is UL Listed as Switching duty and High Intensity Discharge. HACR rated.