Schneider Electric

Schneider Electric EGB34050AABASA Mini circuit breaker, E-Frame, 50A, 3 pole, 480Y/277VAC, 65kA max, bolt on, aux switch, alarm switch, shunt trip

(No reviews yet) Write a Review
SKU:
EGB34050AABASA
MPN:
EGB34050AABASA
Condition:
New
Number Of Spaces:
4
Depth:
4.05 in
Module Type:
E-Frame
Trip Unit Rating:
1800-1800 A
Number Of Spaces Required:
4
Range Of Product:
125 A Frame EDB-EGB-EJB
Eu Rohs Directive:
Compliant with Exemptions
Product Destination:
NF panelboard
Electrical Connection:
lugs aluminium
Trip Unit Technology:
thermal-magnetic
Device Short Name:
EGB
Ambient Air Temperature For Operation:
40°C
Line Rated Current:
50 A
Rohs Exemption Information:
Yes
Breaking Capacity:
35 kA 277 V AC || 65 kA 240 V AC || 35 kA 480Y/277 V AC || 65 kA 120 V AC || 65 kA 120/240 V AC
Holding Current:
630 A
Breaking Capacity Code:
G
Local Signaling:
trip indicator
Product Or Component Type:
miniature circuit-breaker
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Weight:
4 lb(US)
Country of Origin:
Ireland
Circuit Breaker Application:
HACR rated || HID rated
Tightening Torque:
3.9-3.9 N.m 2.5-6 mm² (AWG 14...AWG 10) || 5.6-5.6 N.m 10-70 mm² (AWG 8...AWG 2/0)
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Number Of Poles:
3
[Ue] Rated Operational Voltage:
480Y/277 V AC
Product Certifications:
cULus
Net Weight:
4 lb(US)
Mercury Free:
Yes
Protection Type:
overload || short-circuit
Mounting Mode:
bolt-on
Awg Gauge:
AWG 12...AWG 2/0 aluminium || AWG 14...AWG 2/0 copper
Device Composition:
shunt trip || auxiliary switch || alarm switch
$2,198.00

Description

E-Frame Breaker are Lighting Panelboard Circuit breakers that are proven effective and reliable which provide a wide variety or robust features that are use specifically in Square D NF Panelboards. This range of breaker is ideally designed to offer superior overload and short circuit protection. All E-Frame breakers have a thermal-magnetic trip unit as well as signal indicator that will indicate when a trip has occur. Mounting bolts are used to hold these breakers in place. This E-Frame breaker is 50A, 3 pole, and has an operating voltage of 480Y/277 VAC. It also provides a 65 kA max interrupt rating at 120 VAC. This device has a hold current of 630A which is the maximum current the breaker can be held to ensure it will trip and a trip current of 1800A which is the current value when the breaker is guaranteed to trip. Many accessories are available for this breaker. This one includes an auxiliary switch, alarm switch and a shunt trip. This breaker was calibrated for 40 degrees C. This product is UL Listed as High Intensity Discharge. HACR rated.
View AllClose