Schneider Electric

Schneider Electric EX112T3HFCUNLP Transformer, dry type, DOE 2016, 112.5kVA, 3 phase, 480V delta primary, 208Y/120V secondary, 22K, 115C rise, Cu, K13

(No reviews yet) Write a Review
SKU:
EX112T3HFCUNLP
MPN:
EX112T3HFCUNLP
Condition:
New
Device Short Name:
DOE 2016
Net Weight:
576.06 kg
Weight:
576.06 kg
Circularity Profile:
N/A
Percentage Reactance:
0.000265
Product Or Component Type:
transformer
Toxic Heavy Metal Free:
Yes
Type Of Cooling:
natural convection
Rohs Exemption Information:
Yes
[Uimp] Rated Impulse Withstand Voltage:
10 kV
Efficiency:
98.97 % at 35 % load factor , 75.0°C
Continuous Thermal Current Rating Factor:
1015.055437584 16.6 % || 1181.61825 25 % || 2075.349 50 % || 3564.90025 75 % || 5650.272 100 %
Mounting Support:
floor || floor, with 7400FMB || ceiling, with 7400CMB22K
Transformer Type:
energy efficient
Device Application:
low voltage electrical distribution
[Ipk] Rated Peak Withstand Current:
10.7 kA
Number Of Tap-Offs:
2 2.5 % FCAN || 4 2.5 % FCBN
Country of Origin:
Mexico
Average Ambient Air Temperature For Operation:
30°C
Material:
copper
Box Number:
22K
Percentage Impedance Voltage:
0.029
X/R Ratio:
2.14
Depth:
723 mm
Rated Operational Power In Va:
112.5 kVA
Sustainable Offer Status:
Green Premium product
Reach Free Of Svhc:
Yes
Degree Of Protection:
UL type 1 || UL type 2, with 7400DS22K || UL type 3R, with 7400WS22K
California Proposition 65:
WARNING: This product can expose you to chemicals including: Phenyl glycidyl ether, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Pvc Free:
Yes
Tap Loss:
259.0 no load (core loss) || 1397.0 load loss (coil loss)
Environmental Disclosure:
ENVPEP1604027EN
Ambient Air Temperature For Operation:
40-40°C
Reach Regulation:
Free of Substances of Very High Concern above the threshold
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Eu Rohs Directive:
Compliant
Electrical Connection:
4 Hole Nema Pad primary 11.1 mm || 4 Hole Nema Pad secondary 11.1 mm || 6 Hole Nema Pad sec - XO 11.1 mm
Secondary Voltage:
208Y/120 V
Range Of Product:
Square D
Phase:
3 phase
Mercury Free:
Yes
Primary Voltage:
480 V delta
Network Frequency:
60 Hz
Temperature Rise:
115°C || 220°C insulated
Noise Level:
47 dB || 3 dB NEMA ST-20
Standards:
UL 1561 || CSA C22.2 No 47 || NEMA ST-20
$21,474.00

Description

EX three phase low voltage dry type distribution transformers from Square D comply with DOE energy conservation standards and Natural Resources Canada (NRCan) minimum energy efficiency levels. This transformer is a 112.5kVA, 480V primary (three wire), 208Y/120V secondary (four wire) with copper windings with a 220 insulation system design for 115 degree C temperature rise, K-13 rated. This transformer’s DOE 2016 and NRCan efficiency is a minimum of 98.74% at 35% loading and 75°C temperature. Terminals are designed to accommodate wire ranges sized for 125% of the secondary nameplate current and 250% of the primary nameplate current. The terminals allow for NEMA two hole lugs and wiring bending radius to align with the wire ranges and to allow for side and bottom access. Units are natural air cooled with exhaust vents located on the front only, allowing the transformers to be mounted with rear clearance to obstructions of ½ inch. Units are shipped as Type 1 for indoor installation, field convertible to Type 2 via dripshield for indoor applications with dropping water or to Type 3R via weathershield for outdoor installation. The transformer's open bottom design limits the units to floor mounting. EX transformers have a low sound level, with a minimum of 3dB below NEMA Standard ST-20 requirements. Units are specifically designed to function with other Square D equipment; inrush is coordinated to meet identified breaker trip curves, and IZ levels allow for let through current to match AIR levels of panelboards. See product data sheets for these values.
View AllClose