Schneider Electric

Schneider Electric EX150T3HFNLP Transformer, dry type, DOE 2016, 150kVA, 3 phase, 480V delta primary, 208Y/120V secondary, 25J, 115C rise, K13

(No reviews yet) Write a Review
SKU:
EX150T3HFNLP
MPN:
EX150T3HFNLP
Condition:
New
Country of Origin:
Mexico
Secondary Voltage:
208Y/120 V
Weight:
700.8 kg
Type Of Cooling:
natural convection
Mounting Support:
floor || floor, with 7400FMB
[Ipk] Rated Peak Withstand Current:
13.9 kA
Halogen Content Performance:
Halogen free plastic parts product
Continuous Thermal Current Rating Factor:
1278.219653824 16.6 % || 1479.955 25 % || 2562.412 50 % || 4366.507 75 % || 6892.24 100 %
Net Weight:
700.8 kg
Ambient Air Temperature For Operation:
40-40°C
Device Application:
low voltage electrical distribution
Tap Loss:
328.0 no load (core loss) || 1692.0 load loss (coil loss)
Device Short Name:
DOE 2016
Product Or Component Type:
transformer
Depth:
832 mm
Range Of Product:
Square D
Standards:
UL 1561 || CSA C22.2 No 47 || NEMA ST-20
[Uimp] Rated Impulse Withstand Voltage:
10 kV
Mercury Free:
Yes
Box Number:
25J
Number Of Tap-Offs:
2 2.5 % FCAN || 4 2.5 % FCBN
Sustainable Offer Status:
Green Premium product
Rated Operational Power In Va:
150 kVA
Transformer Type:
energy efficient
Percentage Reactance:
0.000278
Efficiency:
99.04 % at 35 % load factor , 75.0°C
Material:
aluminium
Phase:
3 phase
Temperature Rise:
115°C || 220°C insulated
Primary Voltage:
480 V delta
Reach Free Of Svhc:
Yes
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Noise Level:
49 dB || 7 dB
Environmental Disclosure:
ENVPEP1604028EN
Percentage Impedance Voltage:
0.03
Eu Rohs Directive:
Compliant
California Proposition 65:
WARNING: This product can expose you to chemicals including: Phenyl glycidyl ether, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Toxic Heavy Metal Free:
Yes
Pvc Free:
Yes
Degree Of Protection:
UL type 1 || UL type 2, with 7400DS25J || UL type 3R, with 7400WS25J
Electrical Connection:
4 Hole Nema Pad primary 11.1 mm || 6 Hole Nema Pad secondary 11.1 mm || 8 Hole Nema Pad sec - XO 11.1 mm
Average Ambient Air Temperature For Operation:
30°C
Network Frequency:
60 Hz
X/R Ratio:
2.47
Rohs Exemption Information:
Yes
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
$15,952.00

Description

EX three phase low voltage dry type distribution transformers from Square D comply with DOE energy conservation standards and Natural Resources Canada (NRCan) minimum energy efficiency levels. This transformer is a 150kVA, 480V primary (three wire), 208Y/120V secondary (four wire) with aluminum windings with a 220 insulation system design for 115 degree C temperature rise, K-13 rated. This transformer’s DOE 2016 and NRCan efficiency is a minimum of 98.83% at 35% loading and 75°C temperature. Terminals are designed to accommodate wire ranges sized for 125% of the secondary nameplate current and 250% of the primary nameplate current. The terminals allow for NEMA two hole lugs and wiring bending radius to align with the wire ranges and to allow for side and bottom access. Units are natural air cooled with exhaust vents located on the front only, allowing the transformers to be mounted with rear clearance to obstructions of ½ inch. Units are shipped as Type 1 for indoor installation, field convertible to Type 2 via dripshield for indoor applications with dropping water or to Type 3R via weathershield for outdoor installation. The transformer's open bottom design limits the units to floor mounting. EX transformers have a low sound level, with a minimum of 3dB below NEMA Standard ST-20 requirements. Units are specifically designed to function with other Square D equipment; inrush is coordinated to meet identified breaker trip curves, and IZ levels allow for let through current to match AIR levels of panelboards. See product data sheets for these values.